Extreme Data Center (VOSS/VSP) study materials
Extreme Data Center (VOSS/VSP) study resources

Extreme Data Center (VOSS/VSP) flashcards

Extreme Data Center (VOSS/VSP) · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

What is VOSS?
Versatile Operating System: the Linux-based modular network OS that runs on Extreme VSP switches, providing CLI, Fabric Connect, routing, and HA features.
What is a VSP?
Virtual Services Platform: Extreme's family of data-center and campus switches (4000, 7000, 8000, 9000) that run VOSS and support Fabric Connect and SPB.
What is Fabric Connect?
Extreme's implementation of SPB that separates service from transport, using I-SIDs for services and IS-IS SPB for the backbone, enabling automated provisioning.
Spine-leaf topology
A two-tier data-center design where every leaf switch connects to every spine switch; SPB IS-IS runs on all fabric links to build shortest-path trees.
VSP partition mode
A boot-time setting that configures a VSP chassis as either a single 4-slot switch or two independent 2-slot virtual switches, affecting port numbering and HA.
Default management IP
Factory-default VSP switches use 192.168.10.1/24 on the dedicated Management port for out-of-band access before in-band management is configured.
Save configuration command
Use 'save config' or 'copy running-config startup-config' to persist changes; unsaved changes are lost on reload. Compare with 'show running-config' and 'show startup-config'.
Software upgrade procedure
Download the image with 'download' from TFTP/FTP/SFTP, verify with 'show boot', then 'boot' from the new image. Confirm with 'show software'.
NTP configuration
Configure with 'ntp server <ip>' and verify with 'show ntp status'. Accurate time is required for certificate validation, log correlation, and troubleshooting.
Syslog configuration
Configure with 'logging host <ip>' and 'logging severity <level>'; use 'logging buffered' for local storage. Verify with 'show logging'.
Enabling Fabric Connect
Enable globally with 'fabric enable', create an IS-IS instance with 'router isis', and configure 'spbm' under the IS-IS instance to form the SPB backbone.
What is Auto-Sense?
A Fabric Attach feature that automatically detects clients on access ports and assigns them to services without manual VLAN/I-SID provisioning. Enable with 'auto-sense enable'.
Fabric Attach protocol
An IEEE 802.1Qcj client/server protocol over LLDP that lets access devices request VLAN/I-SID element assignments from the Fabric Attach server (the VSP).
Zero-touch auto-configuration
A boot process where DHCP options 66/67 point a new switch to a configuration server, which downloads and applies a configuration on first boot.
IS-IS NET address
The Network Entity Title used by IS-IS; the system ID is derived from the chassis MAC and must be unique per node in the fabric.
What is SPB?
Shortest Path Bridging (IEEE 802.1aq) uses IS-IS to compute shortest paths and install unicast and multicast forwarding entries for all I-SIDs across the fabric.
B-VLAN in SPB
The backbone VLAN that carries SPB transport traffic. It must be consistent across the fabric; the primary B-VLAN carries unicast and multicast.
SPB nickname
A unique identifier for an SPB node, derived from the system ID by default or set with 'spbm nickname <value>'; nicknames must be unique in the fabric.
SPB ECMP
Equal-cost multipath in SPB is automatic across equal-cost spine paths; traffic is hashed across available paths for load sharing.
What is an I-SID?
A fabric-wide service identifier (1-16777215) that maps VLANs across the SPB backbone. The same I-SID is configured on every edge switch in the service.
L2 VSN provisioning
Create a VLAN, enable 'i-sid <id>' under it, then bind it to the SPBM instance with 'spbm i-sid <id> vlan <vid>'. Repeat on every edge switch.
VLAN vs I-SID
A VLAN is a local Layer 2 broadcast domain on one switch; an I-SID is a fabric-wide service identifier that extends a service across the SPB backbone.
VLAN translation
A VSP feature that maps an ingress VLAN to a different internal VLAN before I-SID mapping, useful for connecting external networks with different VLAN schemes.
What is an L3 VSN?
A routed service over SPB with its own VRF and IP subnet; configured with 'i-sid <id>' plus 'vrf <name>' under the IS-IS SPBM instance.
VRF configuration
Create with 'ip vrf <name>' and assign interfaces with 'ip vrf forwarding <name>' under the interface. VRFs are isolated by default.
DHCP relay
Configure with 'ip dhcp-relay' and 'ip dhcp-relay fwd-path <server-ip>' to forward DHCP requests from a client subnet to a centralized DHCP server.
VRRP on VSP
First-hop redundancy configured with 'ip vrrp <vrid> address <ip>' on an SVI; verify with 'show ip vrrp'. Provides a redundant default gateway.
What is SMLT?
Split Multi-Link Trunking: Extreme's MC-LAG technology where two aggregation switches form an IST and present a single logical LAG to access switches.
IST in SMLT
The inter-switch trunk that carries control traffic between SMLT peers. Configure with 'interface ist' and 'ist' under the peer switches; verify with 'show ist'.
What is RSMLT?
Routed SMLT: provides redundant L3 gateways across SMLT peers; both peers answer ARP and forward traffic, eliminating suboptimal routing.
BFD on VOSS
Bidirectional Forwarding Detection accelerates failure detection for OSPF, BGP, and IS-IS. Enable with 'bfd enable' and per-protocol 'bfd'.
show tech command
Collects a full diagnostic bundle (config, logs, counters) for support cases; 'show tech <module>' narrows the output to a specific area.