FL Fumigation flashcards
FL Fumigation · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT product
- The product of fumigant concentration and exposure time (C × T), used to express and compare fumigation efficacy; a target CT must be achieved for the most tolerant pest life stage present.
- Vapor density and stratification
- Gases heavier than air, such as sulfuryl fluoride and methyl bromide, sink and accumulate in basements, crawlspaces, and low voids, so monitoring and ventilation points must include the lowest spaces.
- Phosphine flammability threshold
- Phosphine can ignite spontaneously at concentrations above about 1.8 percent by volume in air, so it must never be confined in unvented containers or allowed to accumulate in closed spaces.
- Odor is not a warning
- Methyl bromide and sulfuryl fluoride are essentially odorless and cause olfactory fatigue; only calibrated detectors or colorimetric tubes can confirm safe or effective concentrations.
- Chloropicrin warning agent
- A lacrimatory compound added to some fumigants so its tear-gas effect warns of exposure; it is itself toxic and irritating and does not replace gas monitoring.
- SDS Section 8 exposure limits
- Section 8 lists occupational exposure limits such as OSHA PELs and ACGIH TLVs, for example methyl bromide at 20 ppm TWA and sulfuryl fluoride at 5 ppm TWA.
- Label as law
- Under FIFRA, the registered label is legally binding; applying a fumigant at a rate, site, or method not permitted by the label is a violation regardless of intent.
- Fumigation notice posting
- A warning notice stating the fumigant, applicator firm, date, and a 24-hour contact must be posted at every entrance before gas is introduced and left until clearance is confirmed.
- Fumigation management plan
- A site-specific document required by many fumigant labels that records target pest, volume, sealing method, dosage, monitoring schedule, safety plan, and emergency contacts, kept on site.
- Buffer zone determination
- The perimeter distance taken from label tables based on application rate, structure size, and structure type; it must be cleared of people and posted before fumigant introduction.
- Record retention for fumigation
- Federal rules generally require pesticide application records be kept at least two years, and some state rules require longer; records must be produced to regulators on request.
- Drywood termite diagnosis
- Drywood termites live entirely in wood, push out six-sided fecal pellets from kick-out holes, and form small colonies; whole-structure fumigation is the standard curative treatment for inaccessible infestations.
- Subterranean termites and fumigation
- Fumigation kills termites inside a structure but does not eliminate the soil colony, so subterranean termites require soil-applied termiticide rather than structure fumigation alone.
- Egg tolerance to fumigants
- Eggs of many insects tolerate fumigants better than larvae and adults, so dosage and exposure must be set to kill the most tolerant stage present, often requiring longer exposure.
- Sulfuryl fluoride target range
- Sulfuryl fluoride penetrates wood well and kills all termite castes and many wood-boring beetles; it is odorless, nonflammable, heavier than air, and requires monitoring at low points.
- Structure volume measurement
- Volume is calculated from exterior dimensions including attics, crawlspaces, and connected voids, and is measured rather than estimated; it is the basis for the total fumigant dosage calculation.
- Connected-space assessment
- Shared attics, plumbing chases, HVAC ducts, and common walls can carry gas into adjacent units, so those units must be included in the treated volume or positively sealed off.
- Pre-introduction occupant verification
- Before sealing and releasing gas, the applicator must confirm that all occupants, pets, and plants are out, with special attention to persons needing assistance and to attached units.
- Weather effects on fumigation
- Wind stresses tarps and increases gas loss, temperature changes dosage and volatilization, and rain can break seals, so introduction timing and monitoring frequency must account for forecast conditions.
- Tarp securing sequence
- Fumigation tarps are sized to cover roof and walls with overlap, then secured with sand snakes, clamps, and ropes, sealing the tarp-to-ground junction to limit leakage.
- Interior preparation for fumigation
- Food, feed, medications, and perishables are removed or double-bagged, plants and pets removed, and interior doors and cabinets opened so gas distributes throughout the structure.
- Monitoring line placement
- Monitoring lines are placed at high and low points and in remote voids; readings verify target concentration and detect leakage at the tarp perimeter and adjacent spaces.
- Dosage per thousand cubic feet
- Label rates are given per 1,000 cubic feet; total fumigant equals structure volume divided by 1,000, multiplied by the label rate, with temperature adjustments where specified.
- Temperature correction of dosage
- Many labels require increased dosage below a threshold temperature because volatilization and insect activity slow; the specific label table must be used rather than extrapolated.
- Phosphine tablet placement
- Phosphine tablets and pellets release gas on contact with atmospheric moisture; they are placed in shallow trays or on paper, never piled or stacked, and never confined in sealed containers.
- Introduction point selection
- Heavier-than-air fumigants are introduced high and monitored low; controlled release rates and fans where permitted prevent pooling and improve distribution into voids.
- Aeration sequence
- Aeration starts after the required exposure, opening the structure from top down and far end toward the exit, removing tarps and seals to allow cross-ventilation and mechanical exhaust.
- Clearance level
- The label-specified maximum airborne concentration, confirmed by a calibrated detector, that must be reached before re-entry without respiratory protection is allowed.
- Clearance sampling locations
- Readings must be taken at the lowest points, basements, crawlspaces, closets, and cabinets where gas pools; a single reading at the entry door is insufficient for clearance.
- Phosphide spill response
- Never apply water or acid to spilled aluminum or magnesium phosphide because it liberates flammable phosphine; cover with dry sand or earth, collect with nonsparking tools, and containerize outdoors.
- Respirator selection for fumigants
- Only NIOSH-approved respirators with the correct canister, or supplied-air/SCBA for high or unknown concentrations, may be used; escape-only respirators are not for entry into IDLH atmospheres.
- Inhalation first aid
- Move the victim to fresh air, call 911, keep them quiet and warm, give oxygen if trained, and use a barrier device rather than mouth-to-mouth when exposure status is unknown.