FOA CFOS/C flashcards
FOA CFOS/C · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Numerical aperture
- NA = sqrt(n_core^2 - n_cladding^2); it describes the light-gathering ability of a fiber and relates to the maximum acceptance angle by sin(theta_max) = NA.
- Total internal reflection
- Light stays in the core when it strikes the core-cladding boundary above the critical angle, which is arcsin(n_cladding/n_core). This is the basis of fiber guidance.
- Graded-index multimode
- A multimode fiber whose core refractive index decreases toward the cladding, equalizing path lengths and reducing modal dispersion compared with step-index multimode.
- Single-mode fiber
- Fiber with an 8-10 um core that supports one propagation mode, used at 1310 nm and 1550 nm for long-distance and high-bandwidth links.
- OM3 and OM4
- Laser-optimized 50/125 um multimode fibers; OM4 offers higher bandwidth and longer reach than OM3 for 10G and higher Ethernet applications.
- Macrobend vs microbend
- Macrobend loss comes from large-radius bends visible to the eye; microbend loss comes from small random stresses along the fiber axis. Both increase at longer wavelengths.
- Laser safety rule
- Never look into a fiber end or connector; treat all fiber as potentially live and follow laser-safety procedures and eye protection requirements.
- TIA-568 categories
- The standard defining copper categories (Cat 5e, 6, 6A, 8) and fiber types (OM1-OM5, OS1/OS2) for premises telecommunications cabling.
- Horizontal cabling length
- Maximum horizontal channel is 90 m of permanent link plus 10 m of patch cords, totaling 100 m per TIA-568.
- TIA-569
- The standard for telecommunications pathways and spaces, covering conduit, cable tray, and separation from power in premises installations.
- TIA-606
- The administration standard for labeling and documenting cables, pathways, and spaces so that the cabling system can be managed and maintained.
- LC connector
- A small-form-factor fiber connector with a 1.25 mm ferrule, widely used for high-density premises links and compatible with SFP transceivers.
- MPO polarity methods
- TIA-568 defines Method A, B, and C for MPO trunk polarity; the method determines pinning and fiber mapping end to end.
- Plenum cable rating
- CMP-rated cable is required in air-handling spaces; CMR is for risers, and CM/CMX for general-purpose or limited-use areas.
- Pull tension limit
- Typical premises fiber cable allows about 220-300 N (50-70 lbf) during installation; always follow the manufacturer datasheet limit.
- Minimum bend radius
- A common rule is 10x cable OD during installation and 20x OD under load; tight bends cause permanent macrobend loss.
- Fusion splice loss
- A well-made fusion splice typically shows 0.1 dB or less loss; splice trays must protect the splice and maintain bend radius.
- Firestopping
- Listed materials and methods used to restore the fire rating of walls and floors where cables penetrate, required by building codes.
- Service loop
- Extra cable left at both ends of an installation to allow future retermination and maintenance without re-pulling the cable.
- Loss budget formula
- Total link loss = fiber attenuation (dB/km x km) + connector losses + splice losses + safety margin; compare with the transceiver budget.
- Tier 1 testing
- Insertion loss and length measurement with an optical loss test set (light source and power meter), the basic acceptance test for fiber links.
- Tier 2 testing
- Adds an OTDR trace to Tier 1 results to locate events, splices, connectors, and reflections along the fiber link.
- OTDR dead zone
- The distance after an event where the OTDR cannot detect another event; event and attenuation dead zones differ and depend on pulse width.
- Reference method
- One-, two-, or three-jumper reference setups produce different measured loss; the method used must be documented in the test report.
- IEC 61300-3-35
- The standard defining pass/fail criteria for fiber connector end-face inspection zones, used with a fiber inspection scope.
- Inspect-clean-inspect
- The required sequence before mating any connector: inspect with a scope, clean with approved tools, and re-inspect to confirm pass.
- Test wavelength selection
- Use 850/1300 nm for multimode and 1310/1550 nm for single-mode so test results match the application's operating wavelengths.
- Application requirements
- Design inputs include bandwidth, distance, protocol, topology, and environment; these determine fiber type, connector, and transceiver choice.
- Fiber type selection
- Multimode is used for short building and campus links; single-mode is used for long-haul and high-bandwidth links where reach exceeds multimode limits.
- Topology options
- Point-to-point, star, ring, and passive optical LAN (PON) split architectures; each changes loss, component count, and management needs.
- Project phases
- Requirements, design, procurement, installation, testing/acceptance, and as-built documentation form the standard project lifecycle.
- Acceptance criteria
- Acceptance references the applicable standard (e.g., TIA-568, IEC 61300-3-35) and requires test reports, labeling records, and as-built drawings.