FOA CFOS/O flashcards
FOA CFOS/O · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Outside plant definition
- All cable, enclosures, and hardware installed outdoors between the central office or headend and subscriber premises, exposed to weather, moisture, and physical hazards.
- Direct-buried cover depth
- Typical minimum cover for optical cable is about 24 inches under ordinary soil, deeper under roads and cultivated fields; always confirm against the governing local code.
- Installation bend radius rule
- Keep bends at or above 10 times the cable outside diameter while pulling and 20 times the OD after installation; tighter bends cause macrobend loss and possible fiber damage.
- Trench backfill cushion
- Place smooth sand or select backfill around the cable and a warning tape above it, so rocks do not crush the cable and future excavators can locate the route.
- Duct proofing
- Before pulling cable, run a mandrel or brush through the duct to confirm it is clear, round, and continuous; remove debris and verify pull points and drainage.
- Loose-tube OSP cable
- Cable with fibers inside gel-filled or dry water-blocked buffer tubes stranded around a central strength member; the standard construction for high-count outside plant runs.
- Ribbon fiber cable
- Cable containing bonded fiber ribbons that are mass fusion spliced as a unit; a 12-fiber ribbon spliced at once greatly reduces time in high-count plants.
- Armored OSP cable
- Cable with a corrugated steel or aluminum tape layer for rodent, crush, and moisture protection; common in direct-buried and duct installations needing mechanical protection.
- Splice closure requirements
- Closures must be watertight, re-enterable, and matched to the cable sheath and strength-member type; metallic armor or members require bonding and grounding at the closure.
- 12-fiber color code
- The standard buffer tube and fiber sequence is blue, orange, green, brown, slate, white, red, black, yellow, violet, rose, aqua; memorize it for identification and splicing.
- Hardened outdoor connector
- A sealed, weatherproof connector and adapter pair used at FTTx drop terminals and ONT connections, protecting the ferrule end face from moisture and contamination.
- Pull tension monitoring
- Continuously measure tension during a pull and keep it below the manufacturer's rated maximum; a breakaway link or tension meter physically enforces the limit.
- Pulling swivel purpose
- A swivel attaches the pull rope to the cable eye so the cable does not twist as tension is applied, preventing jacket damage and fiber stress.
- Cable pulling lubricant
- A lubricant compatible with the cable jacket and duct, applied along the run rather than only at the entry, to lower friction and pulling tension.
- Air-blowing installation
- Jetting cable into duct with compressed air and a feed unit; it suits long duct and microduct runs and requires clean, continuous duct with gentle offsets.
- Duct fill ratio
- The ratio of cable cross-section to duct inside diameter; jetting commonly targets roughly 50 to 70 percent fill, with exact limits from cable and duct data.
- Sidewall pressure limit
- Force concentrated on the jacket at a bend; sharp corners can exceed limits even when total tension is within spec, so use large-radius bend shoes.
- Slack coil purpose
- Extra cable coiled at handholes, closures, and building entrances so future re-splicing or re-termination can be done without pulling new cable.
- Fusion splice sequence
- Strip, clean with lint-free wipe and alcohol, cleave to under about 0.5 degree, align in the splicer, arc-fuse, proof-test, and protect with a splice sleeve.
- Cleave angle importance
- A poor cleave angle or chipped end raises splice loss and reflection; the splicer's estimated loss will show it, so re-cleave before fusing.
- Typical fusion splice loss
- A good single-mode fusion splice is typically below 0.1 dB; field acceptance commonly allows 0.1 to 0.3 dB per splice depending on the standard.
- End-face inspection
- Scope and inspect every connector end face for scratches, pits, cracks, and contamination before mating; a dirty face can permanently damage the mating connector.
- Connector cleaning rule
- Dry clean first with a lint-free wipe or cassette cleaner; if contamination remains, use isopropyl alcohol on a lint-free wipe and dry fully. Never use compressed air.
- UPC versus APC
- UPC is a flat polish with low reflectance; APC is an angled polish with the best reflectance. APC and UPC must never be mated because the end faces do not match.
- Link loss budget
- Total loss equals fiber attenuation times length plus splice losses plus connector losses plus splitter losses; compare the measured value against the budget, not a generic number.
- Single-mode attenuation values
- Typical single-mode fiber attenuation is about 0.35 dB per km at 1310 nm and about 0.20 to 0.25 dB per km at 1550 nm.
- OTDR distance formula
- Distance equals the speed of light times time divided by twice the group index; if the IOR setting is wrong, every reported distance is wrong.
- OTDR dead zones
- The event dead zone limits resolving closely spaced reflective events; the longer attenuation dead zone limits loss measurement right after a reflective event. Shorter pulses improve resolution.
- Bidirectional OTDR testing
- Splice loss measured from one direction is biased by backscatter differences; test both directions and average the two readings for accurate splice loss.
- Visual fault locator use
- A red laser VFL finds breaks, tight bends, and bad connectors within a short range by making the fault glow through the jacket or connector.
- Laser eye safety
- Never look into a fiber or connector; treat every fiber as live, verify with a power meter, and cap unused ports, because laser eye damage is instant and painless.
- Fiber shard handling
- Broken fiber shards cut skin and threaten eyes; work on a dark mat, pick shards up with tape or a damp wipe, and never blow debris with compressed air.
- Confined space entry
- Handholes and vaults may be permit-required confined spaces; test oxygen, flammable gas, and toxic gas before entry and keep a standby attendant outside.