GA Fire Sprinkler study plan
GA Fire Sprinkler · Give each week a clear focus.
8 weeks · About 7 hours per week
NFPA 13: Installation of Sprinkler Systems - design criteria, occupancy classification, and system types
Map every occupancy hazard classification in NFPA 13 (light, ordinary Group 1 and 2, extra Group 1 and 2) to a real building type you have worked in or can name from memory, and write the density/area starting point for each
Distinguish the four system types (wet-pipe, dry-pipe, preaction, deluge) by when each is required or preferred, and list the triggering condition for each
Trace how design criteria are selected: occupancy classification, then density/area curve, then sprinkler type, then hydraulic demand, and write the decision order as a one-page flowchart
Read the NFPA 13 scope and chapter structure so you can locate a rule fast, and note which chapters cover design, installation, and acceptance
Your checkpoint
A one-page occupancy-to-density reference sheet plus a hand-drawn system-type selection flowchart, both self-quizzable without notes
NFPA 13: Installation of Sprinkler Systems - design criteria, occupancy classification, and system types & NFPA 13: Sprinkler spacing, coverage, obstruction rules, and hydraulic calculations
Compute sprinkler spacing and coverage limits for light and ordinary hazard using the area-per-sprinkler and maximum-spacing tables, and check branch-line and sprinkler-to-wall distances
Apply the obstruction rules for sprinklers near walls, beams, ducts, and soffits, and decide when a sprinkler is omitted versus added
Set up a simple hydraulic calculation by hand for a single branch line: start at the most remote sprinkler, apply friction loss, and add elevation and device losses
Identify where the density/area method and the room-design method diverge, and state when each is acceptable
Your checkpoint
A worked hand calculation for one branch line with spacing and coverage checks annotated, showing every step and the code basis for each limit
NFPA 13: Sprinkler spacing, coverage, obstruction rules, and hydraulic calculations & Water supply analysis, fire pumps, and standpipe systems
Extend the hand calculation to a full tree system including cross-main, riser, and supply, and balance the demand against a water supply curve
Read a water flow test result and derive available pressure at the base of the riser using the N^1.85 friction formula and the supply curve
Size a fire pump for a given demand and suction condition, and identify churn, rated, and peak points on a pump curve
Classify standpipe systems (automatic wet, automatic dry, manual wet, manual dry) and state where each is required and how they interact with sprinkler demand
Your checkpoint
A complete hydraulic demand calculation with supply-curve overlay showing a pass or fail against the required density, plus a one-paragraph pump sizing justification
NFPA 13R and NFPA 13D: Residential and low-rise sprinkler systems & Water supply analysis, fire pumps, and standpipe systems
Contrast NFPA 13R and NFPA 13D scope limits: height, dwelling units, and when each may replace a full 13 system
State the design approach for 13D (one- or two-sprinkler flow, 10-minute duration) and for 13R (density/area with reduced duration) and list the differences from 13
Identify the exemptions and allowances unique to residential systems, such as attic and closet omissions, and when they do not apply
Review a standpipe and pump scenario where a residential system ties into a combined supply
Your checkpoint
A side-by-side comparison table of 13, 13R, and 13D covering scope, design basis, duration, and omission rules, with a short written answer to one combined 13R-plus-standpipe scenario
NFPA 25: Inspection, testing, and maintenance of water-based fire protection systems
Build an ITM calendar from NFPA 25 for weekly, monthly, quarterly, annual, and five-year tasks on wet, dry, and preaction systems
State the acceptance test sequence for a new system (hydrostatic, flow test, main drain, alarm and supervisory signals) and who witnesses each
Define impairment procedures, tag colors, and the notification chain when a system is out of service
List the common deficiencies found on internal pipe inspection and what triggers a five-year internal assessment
Your checkpoint
A one-page ITM frequency matrix by system type, plus a written impairment procedure in five steps or fewer
Georgia Rules and Regulations for Fire Sprinkler Contractors and licensing requirements
Identify the Georgia state agency that licenses fire sprinkler contractors and the license categories, and state the qualifying-agent requirement
List the contractor responsibilities under Georgia rules: supervision of installations, certificate of competency, and recordkeeping
State the continuing education and renewal obligations for Georgia sprinkler licenses, including hours and cycle
Explain the disciplinary and penalty framework for unlicensed contracting or code violations
Your checkpoint
A Georgia licensing fact sheet covering license types, qualifying agent, renewal, CE hours, and penalties, written from your own notes and cross-checked against the current rule text
Georgia adoption of codes and standards, permitting, and plan review procedures & Georgia Rules and Regulations for Fire Sprinkler Contractors and licensing requirements
Trace how Georgia adopts model codes and standards, including which edition of NFPA 13 and 25 applies and how adoption lags publication
Outline the permit and plan review sequence for a sprinkler installation from submittal to final inspection, and name the documents typically required
Identify local amendments or authority-having-jurisdiction variations that affect plan review in Georgia jurisdictions
Connect licensing rules to permitting: who may sign and submit plans, and what happens when the contractor of record changes mid-project
Your checkpoint
A permit-to-final-inspection process map with a document checklist at each step, annotated with the code or rule citation for each requirement
General trade knowledge, safety, and jobsite practices & NFPA 13: Installation of Sprinkler Systems - design criteria, occupancy classification, and system types & NFPA 13: Sprinkler spacing, coverage, obstruction rules, and hydraulic calculations & NFPA 25: Inspection, testing, and maintenance of water-based fire protection systems & Georgia Rules and Regulations for Fire Sprinkler Contractors and licensing requirements
Review jobsite safety practices for sprinkler work: pipe handling, overhead work, hot work permits, and lockout during tie-ins
Re-run two timed mixed-domain practice sets and log every missed question by domain and root cause
Re-derive the hydraulic calculation from week 3 without notes to confirm retention
Recite the Georgia licensing and permitting essentials from memory in under five minutes
Your checkpoint
A scored practice-exam log with a written remediation note for each missed item, plus a one-page final review sheet of the ten facts you most often missed
Milestones
Week 2: You can select occupancy classification, density, and sprinkler spacing for an unfamiliar building and defend each choice with a code citation, without opening the book for more than one lookup
Week 4: You complete a full hydraulic demand calculation with supply-curve overlay in under 45 minutes and correctly state whether the design passes
Week 5: You score at least 80 percent on a self-made 30-question set covering domains 1 through 4, with no more than two misses in any single domain
Week 7: You can explain the Georgia licensing, adoption, and permitting chain end to end in a five-minute recorded or written summary with correct agency and rule references
Week 8: You score at least 85 percent on a full-length mixed practice exam and have a written remediation note for every missed item