GA Fire Sprinkler study materials
GA Fire Sprinkler study resources

GA Fire Sprinkler study plan

GA Fire Sprinkler · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

NFPA 13: Installation of Sprinkler Systems - design criteria, occupancy classification, and system types

  • Map every occupancy hazard classification in NFPA 13 (light, ordinary Group 1 and 2, extra Group 1 and 2) to a real building type you have worked in or can name from memory, and write the density/area starting point for each

  • Distinguish the four system types (wet-pipe, dry-pipe, preaction, deluge) by when each is required or preferred, and list the triggering condition for each

  • Trace how design criteria are selected: occupancy classification, then density/area curve, then sprinkler type, then hydraulic demand, and write the decision order as a one-page flowchart

  • Read the NFPA 13 scope and chapter structure so you can locate a rule fast, and note which chapters cover design, installation, and acceptance

Your checkpoint

A one-page occupancy-to-density reference sheet plus a hand-drawn system-type selection flowchart, both self-quizzable without notes

Week 2

NFPA 13: Installation of Sprinkler Systems - design criteria, occupancy classification, and system types & NFPA 13: Sprinkler spacing, coverage, obstruction rules, and hydraulic calculations

  • Compute sprinkler spacing and coverage limits for light and ordinary hazard using the area-per-sprinkler and maximum-spacing tables, and check branch-line and sprinkler-to-wall distances

  • Apply the obstruction rules for sprinklers near walls, beams, ducts, and soffits, and decide when a sprinkler is omitted versus added

  • Set up a simple hydraulic calculation by hand for a single branch line: start at the most remote sprinkler, apply friction loss, and add elevation and device losses

  • Identify where the density/area method and the room-design method diverge, and state when each is acceptable

Your checkpoint

A worked hand calculation for one branch line with spacing and coverage checks annotated, showing every step and the code basis for each limit

Week 3

NFPA 13: Sprinkler spacing, coverage, obstruction rules, and hydraulic calculations & Water supply analysis, fire pumps, and standpipe systems

  • Extend the hand calculation to a full tree system including cross-main, riser, and supply, and balance the demand against a water supply curve

  • Read a water flow test result and derive available pressure at the base of the riser using the N^1.85 friction formula and the supply curve

  • Size a fire pump for a given demand and suction condition, and identify churn, rated, and peak points on a pump curve

  • Classify standpipe systems (automatic wet, automatic dry, manual wet, manual dry) and state where each is required and how they interact with sprinkler demand

Your checkpoint

A complete hydraulic demand calculation with supply-curve overlay showing a pass or fail against the required density, plus a one-paragraph pump sizing justification

Week 4

NFPA 13R and NFPA 13D: Residential and low-rise sprinkler systems & Water supply analysis, fire pumps, and standpipe systems

  • Contrast NFPA 13R and NFPA 13D scope limits: height, dwelling units, and when each may replace a full 13 system

  • State the design approach for 13D (one- or two-sprinkler flow, 10-minute duration) and for 13R (density/area with reduced duration) and list the differences from 13

  • Identify the exemptions and allowances unique to residential systems, such as attic and closet omissions, and when they do not apply

  • Review a standpipe and pump scenario where a residential system ties into a combined supply

Your checkpoint

A side-by-side comparison table of 13, 13R, and 13D covering scope, design basis, duration, and omission rules, with a short written answer to one combined 13R-plus-standpipe scenario

Week 5

NFPA 25: Inspection, testing, and maintenance of water-based fire protection systems

  • Build an ITM calendar from NFPA 25 for weekly, monthly, quarterly, annual, and five-year tasks on wet, dry, and preaction systems

  • State the acceptance test sequence for a new system (hydrostatic, flow test, main drain, alarm and supervisory signals) and who witnesses each

  • Define impairment procedures, tag colors, and the notification chain when a system is out of service

  • List the common deficiencies found on internal pipe inspection and what triggers a five-year internal assessment

Your checkpoint

A one-page ITM frequency matrix by system type, plus a written impairment procedure in five steps or fewer

Week 6

Georgia Rules and Regulations for Fire Sprinkler Contractors and licensing requirements

  • Identify the Georgia state agency that licenses fire sprinkler contractors and the license categories, and state the qualifying-agent requirement

  • List the contractor responsibilities under Georgia rules: supervision of installations, certificate of competency, and recordkeeping

  • State the continuing education and renewal obligations for Georgia sprinkler licenses, including hours and cycle

  • Explain the disciplinary and penalty framework for unlicensed contracting or code violations

Your checkpoint

A Georgia licensing fact sheet covering license types, qualifying agent, renewal, CE hours, and penalties, written from your own notes and cross-checked against the current rule text

Week 7

Georgia adoption of codes and standards, permitting, and plan review procedures & Georgia Rules and Regulations for Fire Sprinkler Contractors and licensing requirements

  • Trace how Georgia adopts model codes and standards, including which edition of NFPA 13 and 25 applies and how adoption lags publication

  • Outline the permit and plan review sequence for a sprinkler installation from submittal to final inspection, and name the documents typically required

  • Identify local amendments or authority-having-jurisdiction variations that affect plan review in Georgia jurisdictions

  • Connect licensing rules to permitting: who may sign and submit plans, and what happens when the contractor of record changes mid-project

Your checkpoint

A permit-to-final-inspection process map with a document checklist at each step, annotated with the code or rule citation for each requirement

Week 8

General trade knowledge, safety, and jobsite practices & NFPA 13: Installation of Sprinkler Systems - design criteria, occupancy classification, and system types & NFPA 13: Sprinkler spacing, coverage, obstruction rules, and hydraulic calculations & NFPA 25: Inspection, testing, and maintenance of water-based fire protection systems & Georgia Rules and Regulations for Fire Sprinkler Contractors and licensing requirements

  • Review jobsite safety practices for sprinkler work: pipe handling, overhead work, hot work permits, and lockout during tie-ins

  • Re-run two timed mixed-domain practice sets and log every missed question by domain and root cause

  • Re-derive the hydraulic calculation from week 3 without notes to confirm retention

  • Recite the Georgia licensing and permitting essentials from memory in under five minutes

Your checkpoint

A scored practice-exam log with a written remediation note for each missed item, plus a one-page final review sheet of the ten facts you most often missed

Milestones

Week 2: You can select occupancy classification, density, and sprinkler spacing for an unfamiliar building and defend each choice with a code citation, without opening the book for more than one lookup

Week 4: You complete a full hydraulic demand calculation with supply-curve overlay in under 45 minutes and correctly state whether the design passes

Week 5: You score at least 80 percent on a self-made 30-question set covering domains 1 through 4, with no more than two misses in any single domain

Week 7: You can explain the Georgia licensing, adoption, and permitting chain end to end in a five-minute recorded or written summary with correct agency and rule references

Week 8: You score at least 85 percent on a full-length mixed practice exam and have a written remediation note for every missed item