GA Water/WW Operator flashcards
GA Water/WW Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT value
- CT is disinfectant residual concentration in mg/L multiplied by contact time in minutes; the required CT rises with pH, falls with rising temperature, and depends on the target log inactivation.
- Jar test
- A bench-scale procedure that mixes raw water with varying coagulant doses and pH values to identify the dose producing the lowest settled and filtered turbidity before full-scale adjustments are made.
- Filter backwash trigger
- A rapid sand filter is backwashed when head loss reaches its terminal value, about 8 to 10 feet, or when effluent turbidity breaks through, typically every 24 to 72 hours.
- Surface overflow rate
- A sedimentation design parameter equal to flow rate divided by clarifier surface area, expressed in gpm per square foot; lower values give longer detention and better particle removal.
- Chlorine demand
- The difference between the chlorine dose applied and the chlorine residual remaining after a contact period; it reflects chlorine consumed by oxidizable material in the water.
- Water hammer
- A pressure surge caused by a rapid change in flow velocity, such as sudden valve closure or pump trip, that travels through the piping and can rupture mains and damage fittings.
- Air gap
- The only backflow prevention method providing absolute protection: a physical separation between the supply outlet and the flood-level rim of the receiving vessel or fixture.
- Hazen-Williams formula
- An empirical equation relating head loss to flow rate, pipe diameter, pipe length, and a roughness coefficient C; C is roughly 130 to 140 for new cement-lined or plastic pipe.
- Distribution chlorine residual
- Free chlorine measured at points throughout the distribution system; a detectable residual, commonly at least 0.2 mg/L, must be maintained to prevent microbial regrowth in the mains.
- Main disinfection per C651
- AWWA C651 requires new water mains to receive an initial 25 mg/L chlorine dose held 24 hours, leaving at least 10 mg/L residual before flushing and coliform sampling.
- Food to microorganism ratio
- Pounds of BOD applied per day divided by pounds of MLVSS in the aeration tank; conventional activated sludge operates in the range of 0.2 to 0.5.
- Mean cell residence time
- Total solids held in the aeration system divided by solids leaving the system per day; it is the sludge age that controls nitrification and the amount of waste sludge produced.
- Sludge volume index
- The volume in milliliters occupied by one gram of settled sludge after 30 minutes of settling; values of 80 to 150 indicate good settling and above 150 suggests bulking.
- Nitrification alkalinity demand
- Oxidizing one milligram of ammonia nitrogen to nitrate consumes about 7.1 milligrams of alkalinity as calcium carbonate, so nitrifying plants may need supplemental alkalinity to hold pH.
- Primary clarifier overflow rate
- A typical design surface overflow rate for a primary clarifier treating municipal wastewater is 600 to 800 gallons per day per square foot, with detention of 1.5 to 2.5 hours.
- Manning's equation
- An equation used to size gravity sewers in which velocity depends on pipe roughness, hydraulic radius, and slope, with n near 0.013 for new concrete or plastic sewer pipe.
- Infiltration and inflow
- Infiltration is groundwater entering sewers through defects, while inflow is stormwater entering through direct connections such as roof drains and manhole covers; both add clear water needing treatment.
- Minimum sewer velocity
- Gravity sewers are designed to carry at least 2 feet per second at design flow so solids stay suspended; velocities above 10 to 15 feet per second can erode the pipe.
- Force main velocity
- Wastewater force mains are typically sized for 2 to 4 feet per second to keep solids in suspension, and pumps cycle periodically to limit septic conditions and sulfide generation.
- Confined space oxygen range
- An acceptable entry atmosphere is 19.5 to 23.5 percent oxygen; below 19.5 percent is oxygen deficient, and above 23.5 percent creates a fire or explosion hazard.
- Hydrogen sulfide IDLH
- Hydrogen sulfide is immediately dangerous to life or health at 100 ppm; it deadens the sense of smell at higher concentrations, so odor is never a reliable warning of exposure.
- Methane explosive range
- Methane's lower explosive limit is 5 percent in air and its upper explosive limit is 15 percent; entry is stopped and the space ventilated when readings reach 10 percent LEL.
- Excavation shoring threshold
- OSHA requires a protective system for trenches 5 feet or deeper, a ladder within 25 feet of lateral travel for trenches 4 feet deep, and spoil piles set back at least 2 feet.
- Lockout tagout
- A six-step energy control procedure: notify affected workers, shut down equipment, isolate all energy sources, apply locks and tags, release stored energy, and verify zero energy before work begins.
- Total coliform rule
- A rule requiring routine coliform monitoring in distribution systems; any positive sample is checked for E. coli, which is an MCL violation, and repeat samples determine follow-up obligations.
- Stage 2 DBPR limits
- Disinfection byproduct limits evaluated as locational running annual averages: total trihalomethanes at 80 micrograms per liter and five haloacetic acids at 60 micrograms per liter.
- Lead action level
- The 90th percentile lead concentration in tap samples is 0.015 mg/L; exceeding it triggers corrosion control treatment, public education, and lead service line replacement obligations.
- NPDES permit
- A Clean Water Act permit issued to point source dischargers that sets effluent limits, monitoring requirements, and reporting, with results filed on monthly discharge monitoring reports.
- BOD5 test
- Five-day biochemical oxygen demand measured at 20 degrees Celsius in the dark; a seeded sample is incubated and dissolved oxygen depletion indicates biodegradable organic content, usually with nitrification inhibited.
- Total suspended solids method
- A measured sample volume is filtered through a glass fiber filter, dried at 103 to 105 degrees Celsius, and weighed; residue increase divided by sample volume gives TSS in mg/L.
- DPD method
- A colorimetric test in which the DPD indicator reacts with chlorine to form a colored compound measured by a photometer; it reports free or total chlorine depending on reagents used.
- pH calibration
- A pH meter is standardized with at least two buffers bracketing the sample, commonly pH 4, 7, and 10, and electrode slope should fall within 95 to 105 percent of theoretical.