Hazmat Operations study materials
Hazmat Operations study resources

Hazmat Operations cheat sheet

Hazmat Operations · Keep the key ideas within reach.

Quick reference

Hazard Identification and Recognition

  • NFPA 704 quadrant order: blue = health, red = flammability, yellow = instability, white = special hazards (OX, W with slash, SA).

  • DOT hazard classes 1-9: 1 explosives, 2 gases, 3 flammable/combustible liquids, 4 flammable solids/spontaneously combustible/dangerous when wet, 5 oxidizers/organic peroxides, 6 toxic/infectious, 7 radioactive, 8 corrosive, 9 miscellaneous.

  • UN hazard identification number (Kemler) first digit 2 = gas, 3 = flammable liquid, 4 = flammable solid, 5 = oxidizing, 6 = toxic, 7 = radioactive, 8 = corrosive; doubled digit = intensification, X prefix = reacts with water.

  • Placards are required for bulk packages (generally >119 gallons liquid or >882 lb gross for solids) and for any quantity of Table 1 materials.

  • Seven clues to hazard identification: occupancy/location, container shape, markings/labels/placards, shipping papers, facility documents, senses, and human behavior.

  • Shipping paper order for hazardous materials: proper shipping name, hazard class/division, UN/NA identification number, and packing group.

  • Pipeline markers give commodity name, operator, and emergency phone; they do not give pressure, flow, or volume.

  • Cryogenic liquids produce visible frost/fog and expand roughly 700-1000 times their liquid volume when vaporized; oxygen-deficient atmospheres below 19.5% O2 are IDLH-adjacent.

Quick reference

Hazard and Risk Assessment

  • Risk = probability of an event x severity of consequences; risk assessment precedes selection of tactical objectives.

  • IDLH is the maximum airborne concentration from which a worker could escape within 30 minutes without irreversible health effects.

  • ERPG-2 is the maximum concentration below which nearly all persons could be exposed for up to 1 hour without irreversible or serious health effects.

  • TLV-TWA is an 8-hour time-weighted average; TLV-STEL is a 15-minute excursion; TLV-C is a ceiling that must never be exceeded.

  • Lower flammability limit (LFL) is the minimum vapor concentration that will burn; below LFL the mixture is too lean, above UFL too rich.

  • Vapor density >1 sinks and collects in low areas; <1 rises. Vapor pressure rises with temperature, increasing off-gassing and downwind hazard.

  • Specific gravity >1 sinks in water; <1 floats. Water-soluble materials disperse in water; insoluble materials form a separate phase.

  • AEGL tiers: AEGL-1 discomfort, AEGL-2 serious long-lasting effects, AEGL-3 life-threatening; used for public protective action decisions.

  • Isolation distances scale with container size and fire involvement; a fire impinging on a container requires the largest initial isolation and evacuation distances.

Quick reference

Notification, Communication, and Incident Command

  • Initial notifications: fire/EMS dispatch, CHEMTREC (1-800-424-9300) or CANUTEC (1-888-226-8832), state/provincial environmental agency, and the National Response Center (1-800-424-8802) for releases meeting reportable quantities.

  • CERCLA reportable quantity triggers a release notification to the National Response Center; the RQ is listed per substance (e.g., 1 lb, 10 lb, 100 lb, 1000 lb).

  • Calls to CHEMTREC should include: caller name and callback, location, material name, quantity, container type, injuries, and current conditions.

  • ICS span of control is 3-7 subordinates per supervisor, with 5 as the target.

  • Incident Command System sections: Operations (tactical), Planning (situation/action plan), Logistics (resources), Finance/Administration (cost).

  • The Incident Action Plan is produced in the Planning Section and covers one operational period; the Safety Officer has authority to halt unsafe operations.

  • Clear text (plain language) is used for radio communication; no ten-codes or agency-specific codes during multi-agency incidents.

  • The emergency response guidebook's initial isolation and protective action distances apply for the first 30 minutes after a release.

Quick reference

Personal Protective Equipment

  • Level A: fully encapsulating vapor-protective suit with SCBA; highest respiratory, skin, and eye protection; required when skin contact or vapor exposure is possible.

  • Level B: chemical-resistant splash suit with SCBA; respiratory protection equivalent to Level A but only splash-level skin protection.

  • Level C: chemical-resistant suit with air-purifying respirator; only when atmosphere is known, IDLH is not exceeded, and oxygen is adequate.

  • Level D: structural firefighting gear or work uniform; no respiratory protection; only for atmospheres known to be non-hazardous.

  • SCBA rated service life is typically 30-60 minutes; working duration is shorter than rated duration due to exertion and stress.

  • Passive PPE (SCBA, encapsulating suit) adds heat stress; entry time must account for work rate, ambient temperature, and suit insulation.

  • Chemical permeation is measured by breakthrough time; degradation is loss of physical strength; permeation can occur with no visible damage.

  • Do not use air-purifying respirators for unknown concentrations, oxygen-deficient atmospheres (<19.5%), or IDLH conditions.

Quick reference

Decontamination

  • Decon corridor order from hot to cold: tool drop, gross decon, primary (technical) decon, secondary decon, then doffing area.

  • Gross decontamination removes the bulk of contaminant; technical decontamination uses soap and water scrubbing; secondary decon verifies reduction.

  • Decon methods: dilution, absorption, adsorption, chemical degradation, and isolation/disposal.

  • Emergency decon can be initiated with any available water source (ladder pipe, engine line, portable shower) before a formal corridor is set up.

  • Decon wastewater must be contained and disposed of as hazardous waste unless confirmed clean; runoff is a secondary contamination source.

  • Responders exiting the hot zone must be decontaminated before doffing PPE; doffing order proceeds from most contaminated to least contaminated.

  • Victims should be decontaminated before transport; hospitals may refuse contaminated patients, so notify receiving facilities.

  • Contaminated PPE and equipment require bagging and labeling with the material name and date for later disposal or cleaning.

Quick reference

Containment and Control Operations

  • Defensive operations include diking, damming, diverting, absorbing, and shutting off remote valves; offensive operations include product control inside the hot zone.

  • Dike far enough from the spill to contain the full volume: dike volume should be at least 1.5 times the spill volume.

  • Damming restricts flow; diversion channels move product to a controlled collection area; both require consideration of slope and downstream receptors.

  • Absorbents: universal (all liquids), oil-only (petroleum on water), and acid/caustic-specific; do not use water-reactive absorbents on reactive materials.

  • Overpack drums and salvage drums allow containment of damaged containers; overpack capacity must exceed the damaged container's volume.

  • Flammable liquid fires: use foam; AFFF is effective on hydrocarbon fuels but not on polar solvents (alcohols require AR-AFFF or alcohol-resistant foam).

  • Vapor suppression methods: foam blanket, vapor-suppressing agents, water spray, and covering the surface.

  • Do not apply water directly to water-reactive materials (e.g., sodium, calcium carbide) or to materials that react to produce toxic or flammable gas.

Quick reference

Response Objectives and Action Planning

  • Response modes: rescue, defensive (containment), offensive (product control), and non-intervention (evacuation only).

  • Rescue is the highest-priority objective but must not be attempted without PPE and a viable plan; rescuer safety takes precedence.

  • The action plan must identify: current conditions, objectives, tactics, resources, and a safety plan for the operational period.

  • Defensive strategy is chosen when the material is unknown, PPE is inadequate, or the risk exceeds the benefit of offensive action.

  • Offensive strategy requires identification of the material, adequate PPE, a trained team, and a viable containment or control method.

  • Protective action decisions: evacuate when time permits and the hazard is growing; shelter-in-place when evacuation would move people through the hazard or time is short.

  • Spill control priorities: isolate, identify, notify, contain, and then control; do not commit to control before identification.

  • Termination criteria: objectives met or abandoned, decon complete, resources released, and the incident debriefed.

Quick reference

Safety, Health, and Hazardous Materials Regulations

  • OSHA 29 CFR 1910.120 (HAZWOPER) covers emergency response: training levels, medical surveillance, PPE, and site safety plans.

  • HAZWOPER training: Awareness level, Operations level, Technician level, Specialist level, and Incident Commander level; refresher training is annual.

  • DOT 49 CFR 171-180 governs placarding, shipping papers, packaging, and emergency response information for transport.

  • CERCLA (Superfund) and the Clean Water Act establish release reporting and reporting requirements; the National Response Center receives reports.

  • RCRA (40 CFR 260-265) governs hazardous waste generation, storage, transport, and disposal.

  • SARA Title III (EPCRA) requires community right-to-know reporting and establishes Local Emergency Planning Committees (LEPCs).

  • The Emergency Planning and Community Right-to-Know Act requires facilities to report hazardous chemical inventories (Tier II) and release inventories (Tier I).

  • NFPA 471/472 cover response to hazardous materials incidents and recommended practices for responders; NFPA 704 is the identification system.

Quick reference

Safety, Health, and Hazardous Materials Regulations

  • HAZWOPER Operations-level responders may perform defensive actions and must be trained annually; they cannot enter atmospheres that are IDLH.

  • Medical monitoring is required for responders who wear respirators or PPE; baseline and periodic exams are required.

  • The buddy system requires at least two responders in the hot zone and a backup team ready to rescue.

  • Heat stress is a primary PPE hazard; signs include confusion, hot dry skin, and collapse; cooling and hydration are the response.

  • Cold stress and hypothermia can occur with cryogenic exposure; frostbite and airway damage are immediate risks.

  • Site safety plan elements: hazard assessment, PPE levels, decon procedures, medical support, and emergency evacuation routes.

  • Exposure records must be maintained for the duration of employment plus 30 years under HAZWOPER.

  • Do not eat, drink, or smoke in the exclusion zone; wash hands and face after doffing and before eating.

Quick reference

Safety, Health, and Hazardous Materials Regulations (continued)

  • The exclusion zone (hot zone) is where contamination is present; the contamination reduction zone (warm zone) is where decon occurs; the support zone (cold zone) is clean.

  • Zone boundaries are marked with barrier tape, cones, and entry control points staffed by a safety officer or entry control officer.

  • The safety officer has the authority to stop operations and must be independent of the operations section.

  • Emergency response plan must address pre-incident planning, notification, evacuation, and mutual aid.

  • Reportable quantities (RQs) are the threshold for CERCLA notification; releases below the RQ may still require state or local reporting.

  • Training records must document the level of training, dates, and instructor; refresher training is required annually for HAZWOPER responders.

  • Respirator fit testing is required annually and whenever a new respirator model is used; medical clearance precedes fit testing.

  • Hazardous waste manifests track waste from generator to disposal facility; the generator retains copies for three years.

Quick reference

Hazard Identification and Recognition (continued)

  • Container shape clues: horizontal cylinders = flammable/compressed gas; vertical cylinders = gas; tank cars with domes = flammable liquid; MC-331 = anhydrous ammonia or propane.

  • Label colors: red = flammable, yellow = oxidizer, white = poison/toxic, blue = health hazard, green = nonflammable gas, orange = explosive.

  • The ERG's four-digit UN/NA number is indexed in the yellow-bordered pages; the blue-bordered pages list by material name.

  • Placards and labels are not reliable if the container is damaged, mislabeled, or the material is unknown; treat unknown materials as the worst case.

  • Odor is not a reliable indicator: some toxic gases (carbon monoxide) are odorless, and odor thresholds vary widely among individuals.

  • Water-reactive materials produce flammable or toxic gas on contact with water; examples include alkali metals, metal hydrides, and calcium carbide.

  • Oxidizers (e.g., nitrates, peroxides, chlorates) can intensify fire and cause spontaneous ignition when mixed with organic materials.

  • Corrosives have pH extremes; both acids and bases cause tissue damage, and the extent depends on concentration, contact time, and temperature.

Quick reference

Hazard and Risk Assessment (continued)

  • Flammable range is bounded by LFL and UFL; concentrations within the range can ignite if an ignition source is present.

  • Flash point is the lowest temperature at which a liquid gives off enough vapor to form an ignitable mixture near its surface.

  • Boiling point and vapor pressure together determine how quickly a liquid produces vapor; low boiling point and high vapor pressure mean rapid off-gassing.

  • The vapor hazard of a spilled liquid is greatest at temperatures above its flash point and when the surface area is large.

  • Toxic exposure is expressed as concentration x time (ppm-minutes); short high exposures and long low exposures can produce different effects.

  • Reactive hazards include polymerization, decomposition, and incompatibility with water, air, or other materials; check the reactivity quadrant and SDS Section 10.

  • The SDS (formerly MSDS) has 16 sections; Section 6 covers accidental release measures, Section 8 exposure controls, Section 9 physical properties.

  • Risk assessment must consider the receptor: population density, sensitive environments, water intakes, and critical infrastructure downwind or downstream.

Quick reference

Notification, Communication, and Incident Command (continued)

  • The first-arriving officer establishes command and remains until command is transferred formally to a higher-ranking or more qualified officer.

  • Unified Command is used when multiple agencies have jurisdiction; each agency retains authority for its own resources.

  • The Operations Section Chief directs tactical operations; the Planning Section Chief prepares the IAP and tracks resources.

  • The Incident Commander sets objectives; the Safety Officer monitors safety and can stop operations; the Liaison Officer coordinates with outside agencies.

  • Communications should include: nature of incident, location, material, quantity, injuries, resources needed, and staging area.

  • Staging areas are located in the cold zone, upwind and uphill, with a single entry and exit point.

  • The ERG's protective action distances are for the first 30 minutes; extend distances for larger releases, fire, or adverse weather.

  • Public warning methods include emergency alert systems, door-to-door notification, and media broadcasts; shelter-in-place instructions should specify closing windows and shutting off ventilation.

Quick reference

Personal Protective Equipment (continued)

  • Chemical-protective clothing is selected by permeation data, not by appearance; check the manufacturer's compatibility chart for the specific material.

  • Fully encapsulating suits have a limited service life and require cooling; entry time is typically shorter than SCBA duration.

  • Glove selection must match the chemical; butyl, nitrile, neoprene, and Viton have different resistance profiles.

  • Structural firefighting turnout gear provides thermal protection but limited chemical resistance; it is not a substitute for chemical-protective clothing.

  • SCBA cylinders are hydrostatically tested every 5 years; visual inspection occurs before each use.

  • Do not remove PPE in the hot zone; doffing occurs in the contamination reduction zone after decontamination.

  • Respirator cartridge change schedules must be based on the material's breakthrough time, not on odor.

  • PPE ensembles must be compatible: suit, gloves, boots, and respirator must seal and not interfere with each other.

Quick reference

Decontamination (continued)

  • Decon solution: soap and water is effective for most materials; some materials require specific neutralizers (e.g., dilute acid for bases).

  • Do not use bleach on ammonia or on acids; mixing can produce toxic gas.

  • Decon of patients: remove contaminated clothing, wash skin with soap and water, and flush eyes with water for at least 15 minutes.

  • Gross decon is performed at the hot/warm zone boundary; technical decon is performed in the warm zone.

  • Decon station layout: one-way flow from dirty to clean, with separate lines for ambulatory and non-ambulatory victims.

  • Decon water temperature should be tepid; hot water increases absorption and cold water can cause hypothermia.

  • Contaminated runoff must be diked and collected; it is a hazardous waste unless tested and confirmed clean.

  • Decon effectiveness is verified by monitoring (e.g., radiation survey, pH paper, or colorimetric indicators) before doffing.

Quick reference

Containment and Control Operations (continued)

  • Diking and damming are defensive tactics; they require an anchor point and a containment volume larger than the spill.

  • Absorbents are applied from the outside edge of the spill inward to avoid spreading the material.

  • Foam blankets suppress vapor and extinguish flammable liquid fires; foam must be applied gently to avoid breaking the blanket.

  • Foam expansion ratio: low expansion (up to 20:1), medium (20-200:1), high (200-1000:1); high-expansion foam is used for confined spaces.

  • Do not use water on a flammable liquid fire unless it is a fine spray for cooling; a solid stream can spread the fire.

  • Plugging and patching can stop a leak from a container; the patch material must be compatible with the product.

  • Transfer operations require grounding and bonding to prevent static ignition.

  • Containment of a gas release is generally not possible; control focuses on isolation, dispersion, and ignition source elimination.

Quick reference

Response Objectives and Action Planning (continued)

  • The response objective hierarchy: life safety, incident stabilization, property conservation, and environmental protection.

  • The size-up should include: container type, material, quantity, fire or not, wind direction, terrain, exposures, and available resources.

  • Defensive operations are appropriate when the material is unidentified, the atmosphere is IDLH, or the risk of offensive action outweighs the benefit.

  • Offensive operations require a trained team, adequate PPE, a viable control method, and a backup team.

  • The IAP should be written for incidents lasting more than one operational period or involving multiple agencies.

  • Evacuation distances should be based on the ERG, plume modeling, or the incident commander's judgment; they should be reassessed as conditions change.

  • Termination includes debriefing, documentation, critique, and release of resources.

  • After-action review should identify what worked, what did not, and what changes are needed for future responses.

Quick reference

Safety, Health, and Hazardous Materials Regulations (continued)

  • OSHA 1910.120 requires a site-specific safety and health plan for hazardous waste operations.

  • The HAZWOPER standard requires medical surveillance for employees exposed above permissible exposure limits for 30 or more days per year.

  • DOT requires emergency response information to accompany shipping papers; this is often the ERG or a equivalent document.

  • The Clean Air Act and Clean Water Act impose reporting and cleanup obligations for releases.

  • The Toxic Substances Control Act (TSCA) regulates chemical substances and requires reporting for new chemicals.

  • The Resource Conservation and Recovery Act (RCRA) requires hazardous waste to be tracked with a manifest and stored with proper labeling and containers.

  • The Emergency Planning and Community Right-to-Know Act requires facilities to report releases and inventories to the LEPC and state.

  • NFPA 472 defines competencies for hazardous materials responders, including awareness, operations, technician, and specialist levels.

Quick reference

Safety, Health, and Hazardous Materials Regulations (continued)

  • Hot zone entry requires a buddy and a backup team; the backup team must be dressed and ready to rescue.

  • Entry control logs record name, time in, time out, and air supply status for each entrant.

  • The safety officer must be trained and empowered to stop unsafe operations.

  • Heat stress management includes work-rest cycles, hydration, cooling, and monitoring for signs of heat exhaustion or heat stroke.

  • Cold stress management includes layered clothing, warming areas, and monitoring for frostbite and hypothermia.

  • Exposure to hazardous materials can cause acute and chronic effects; medical surveillance monitors for both.

  • Responders must not eat, drink, or smoke in the exclusion or contamination reduction zones.

  • Post-incident medical evaluation is required for responders who may have been exposed to hazardous materials.

Quick reference

Hazard Identification and Recognition (continued)

  • The DOT placard for a material with multiple hazards shows the primary hazard class; subsidiary hazards appear on shipping papers.

  • The NFPA 704 white quadrant special hazards: OX = oxidizer, W with a slash = reacts with water, SA = simple asphyxiant.

  • Container markings: UN/NA numbers, proper shipping names, and orientation arrows; missing markings suggest an unknown or mislabeled material.

  • Pipelines carry a commodity marker but the product may change; verify with the operator before assuming contents.

  • The senses are a last-resort clue: never intentionally smell or touch an unknown material.

  • Human behavior (evacuation, panic, or collapse) can indicate the presence and location of a release.

  • Occupancy clues: laboratories, dry cleaners, agricultural suppliers, and paint stores suggest specific material types.

  • The ERG's initial isolation distances are based on the material and container size; they are minimums, not maximums.

Quick reference

Hazard and Risk Assessment (continued)

  • The dose-response relationship describes the relationship between exposure and effect; higher doses generally produce more severe effects.

  • Acute effects appear soon after exposure; chronic effects appear after repeated or long-term exposure.

  • Sensitization can occur with repeated exposure; subsequent exposures may produce a more severe reaction.

  • The permissible exposure limit (PEL) is the OSHA regulatory limit; the TLV is a recommended limit from ACGIH.

  • The immediately dangerous to life or health (IDLH) value is used to select respiratory protection; air-purifying respirators are not used in IDLH atmospheres.

  • The explosion hazard of a flammable liquid depends on the vapor pressure and the flash point; a liquid with a flash point below 100°F is a flammable liquid.

  • The reactivity hazard includes the potential for polymerization, decomposition, and reaction with water or air.

  • The environmental hazard includes toxicity to aquatic life, persistence, and bioaccumulation.

Quick reference

Notification, Communication, and Incident Command (continued)

  • The first-arriving unit should establish command, size up the incident, and request additional resources.

  • The incident commander should establish a command post in the cold zone, upwind and uphill.

  • The command post should have communications, a log, and access to the ERG and SDS.

  • The liaison officer coordinates with outside agencies, including hospitals, utilities, and environmental agencies.

  • The public information officer releases information to the media; only the PIO or IC should speak to the media.

  • The planning section develops the incident action plan and tracks resources and situation status.

  • The logistics section provides resources, including PPE, food, water, and medical support.

  • The finance/administration section tracks costs and handles reimbursement.

Quick reference

Personal Protective Equipment (continued)

  • Level A suits are tested for chemical permeation and must be selected for the specific material.

  • Level B suits provide splash protection but not vapor protection; they are used when the atmosphere is not IDLH and skin contact is limited.

  • Level C requires an air-purifying respirator with the correct cartridge and a known atmosphere.

  • Level D is not appropriate for any hazardous materials incident.

  • Respirator fit testing must be performed annually and whenever a new respirator model is used.

  • SCBA cylinders must be inspected before each use and hydrostatically tested every 5 years.

  • PPE must be decontaminated before doffing; contaminated PPE is bagged and labeled.

  • Heat stress is a major risk with Level A suits; cooling and work-rest cycles are required.

Quick reference

Decontamination (continued)

  • Emergency decon is the immediate removal of contamination using any available water source.

  • Gross decon removes the bulk of the contaminant; technical decon uses soap and water and scrubbing.

  • Secondary decon verifies that contamination has been reduced to an acceptable level.

  • Decon of equipment: tools and PPE are decontaminated or bagged for disposal.

  • Decon of patients: remove clothing, wash with soap and water, and flush eyes for at least 15 minutes.

  • Decon runoff must be contained and disposed of properly.

  • Decon station layout should provide one-way flow from dirty to clean.

  • Decon effectiveness should be verified by monitoring before doffing.

Quick reference

Containment and Control Operations (continued)

  • Diking and damming are defensive tactics that contain the spread of a spill.

  • Absorbents are applied from the outside edge inward.

  • Foam blankets suppress vapor and extinguish flammable liquid fires.

  • Foam expansion ratio: low, medium, and high expansion.

  • Do not use water on a flammable liquid fire unless it is a fine spray for cooling.

  • Plugging and patching can stop a leak from a container.

  • Transfer operations require grounding and bonding.

  • Containment of a gas release focuses on isolation and dispersion.

Quick reference

Response Objectives and Action Planning (continued)

  • The response objective hierarchy: life safety, incident stabilization, property conservation, and environmental protection.

  • Size-up includes container type, material, quantity, fire, wind, terrain, exposures, and resources.

  • Defensive operations are appropriate when the material is unidentified or the atmosphere is IDLH.

  • Offensive operations require a trained team, adequate PPE, a viable control method, and a backup team.

  • The IAP is written for incidents lasting more than one operational period.

  • Evacuation distances should be based on the ERG or plume modeling and reassessed as conditions change.

  • Termination includes debriefing, documentation, critique, and release of resources.

  • After-action review identifies what worked and what needs improvement.

Quick reference

Safety, Health, and Hazardous Materials Regulations (continued)

  • OSHA 1910.120 requires a site-specific safety and health plan for hazardous waste operations.

  • HAZWOPER requires medical surveillance for employees exposed above PELs for 30 or more days per year.

  • DOT requires emergency response information to accompany shipping papers.

  • The Clean Air Act and Clean Water Act impose reporting and cleanup obligations.

  • TSCA regulates chemical substances and requires reporting for new chemicals.

  • RCRA requires hazardous waste to be tracked with a manifest.

  • EPCRA requires facilities to report releases and inventories to the LEPC and state.

  • NFPA 472 defines competencies for hazardous materials responders.

Quick reference

Safety, Health, and Hazardous Materials Regulations (continued)

  • Hot zone entry requires a buddy and a backup team.

  • Entry control logs record name, time in, time out, and air supply status.

  • The safety officer must be trained and empowered to stop unsafe operations.

  • Heat stress management includes work-rest cycles, hydration, and cooling.

  • Cold stress management includes layered clothing and warming areas.

  • Medical surveillance monitors for acute and chronic effects.

  • Responders must not eat, drink, or smoke in the exclusion or contamination reduction zones.

  • Post-incident medical evaluation is required for responders who may have been exposed.