Hazmat Operations study materials
Hazmat Operations study resources

Hazmat Operations flashcards

Hazmat Operations · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

NFPA 704 blue quadrant
The blue quadrant indicates the health hazard rating on a scale of 0 to 4, where 0 is minimal and 4 is severe, based on short-term exposure effects.
Kemler number X prefix
An X prefix on a UN hazard identification number indicates the material reacts dangerously with water, producing flammable or toxic gas.
Shipping paper order
Hazardous materials shipping papers list the proper shipping name, hazard class or division, UN/NA identification number, and packing group in that order.
Bulk placard threshold
Placards are generally required for bulk packages exceeding 119 gallons for liquids or 882 pounds gross weight for solids, and for any quantity of Table 1 materials.
IDLH definition
IDLH is the maximum airborne concentration from which a worker could escape within 30 minutes without irreversible health effects or incapacitation.
Lower flammability limit
The LFL is the minimum vapor concentration in air that will support combustion; below the LFL the mixture is too lean to ignite.
Vapor density rule
A vapor density greater than 1 means the vapor is heavier than air and tends to collect in low-lying areas, increasing exposure risk.
ERPG-2 value
ERPG-2 is the maximum airborne concentration below which nearly all persons could be exposed for up to one hour without irreversible or serious health effects.
AEGL-3 tier
AEGL-3 is the airborne concentration above which the general population could experience life-threatening health effects or death.
National Response Center
The National Response Center at 1-800-424-8802 receives reports of releases that meet or exceed CERCLA reportable quantities.
ICS span of control
Span of control is the number of subordinates reporting to one supervisor; the target is five, with an acceptable range of three to seven.
Unified Command
Unified Command is an ICS application in which multiple agencies with jurisdiction jointly set objectives and manage the incident.
Safety Officer authority
The Safety Officer monitors incident safety and has the authority to halt or modify unsafe operations independent of the Operations Section Chief.
Level A protection
Level A consists of a fully encapsulating vapor-protective suit with SCBA, providing the highest available respiratory, skin, and eye protection.
Level B protection
Level B uses a chemical-resistant splash suit with SCBA, giving the same respiratory protection as Level A but only splash-level skin protection.
Level C limitation
Level C uses an air-purifying respirator and is permitted only when the atmosphere is known, below IDLH, and has adequate oxygen.
Permeation breakthrough time
Breakthrough time is the elapsed time before a chemical permeates a protective material; it determines the safe duration of use for that garment.
SCBA hydrostatic test
SCBA cylinders must be hydrostatically tested every five years and visually inspected before each use.
Decon corridor order
The decon corridor proceeds from hot to cold: tool drop, gross decon, technical decon, secondary decon, and finally doffing.
Gross decontamination
Gross decontamination removes the bulk of the contaminant at the hot/warm zone boundary before more thorough technical decontamination.
Decon runoff handling
Decontamination wastewater must be diked and collected and is treated as hazardous waste unless testing confirms it is clean.
Patient decon flushing
Contaminated patients should have clothing removed, skin washed with soap and water, and eyes flushed with water for at least 15 minutes.
Dike volume rule
A containment dike should hold at least 1.5 times the spilled volume to allow for rainfall, foam, and additional release.
Alcohol-resistant foam
Polar solvents such as alcohols require alcohol-resistant foam; standard AFFF breaks down and is ineffective on these fuels.
Absorbent application
Absorbents are applied from the outside edge of a spill inward to prevent spreading the material over a larger area.
Grounding and bonding
Grounding and bonding equalize static electrical potential between containers and equipment during transfer to prevent ignition of flammable vapors.
Response objective hierarchy
Response priorities are life safety first, then incident stabilization, property conservation, and environmental protection.
Defensive strategy trigger
Defensive operations are chosen when the material is unidentified, the atmosphere is IDLH, or the risk of offensive action exceeds the benefit.
Shelter-in-place decision
Shelter-in-place is chosen when evacuation would move people through the hazard or when there is insufficient time to evacuate safely.
HAZWOPER training levels
HAZWOPER defines awareness, operations, technician, specialist, and incident commander levels, with annual refresher training required.
CERCLA reportable quantity
A reportable quantity is the threshold release amount for a hazardous substance that triggers notification to the National Response Center.
Hot zone definition
The exclusion or hot zone is the area where contamination is present and where only trained responders in appropriate PPE may enter.