HI Water/WW Operator flashcards
HI Water/WW Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT value
- Product of disinfectant residual concentration in mg/L and contact time in minutes, used to verify disinfection. Required CT depends on temperature, pH, and disinfectant type.
- Chlorine demand
- The difference between chlorine dose applied and chlorine residual remaining after a set contact time. Demand comes from reducing agents, ammonia, organics, and metals in the water.
- Breakpoint chlorination
- The chlorine dose at which combined chlorine residual is destroyed and free chlorine residual begins to rise, occurring roughly at a 7.6 to 1 weight ratio of chlorine to ammonia nitrogen.
- Jar test purpose
- A bench test that varies coagulant dose and pH to find the lowest chemical dose producing acceptable settled turbidity, simulating rapid mix, flocculation, and sedimentation.
- Surface overflow rate
- Clarifier flow in gallons per minute divided by clarifier surface area in square feet, expressed in gpm/ft². It governs particle settling performance independent of basin depth.
- Detention time formula
- Detention time in hours equals basin volume in gallons divided by flow in gallons per day, then divided by 24. Use actual basin volume, not footprint.
- Combined filter effluent limit
- Under conventional treatment, combined filter effluent turbidity must be 0.3 NTU or less in at least 95 percent of monthly samples and never exceed 1 NTU.
- Backwash rate and temperature
- Filter backwash rate is set by water temperature because cold water is more viscous and expands the bed less. Winter backwash rates are lower than summer rates.
- Pressure and head conversion
- One psi equals 2.31 feet of water head, and one foot of head equals 0.433 psi. These convert between pressure gauge readings and elevation head.
- Hazen-Williams head loss
- Head loss in a pipe increases with flow raised to the 1.852 power and decreases as the C factor rises. Rougher, older pipe has a lower C and more loss.
- Water hammer cause
- A pressure surge caused by rapid velocity change in a pipe, such as fast valve closure or pump trip. Mitigation includes slow closure, surge tanks, and air valves.
- Air gap backflow protection
- The only non-mechanical backflow protection: a physical separation between the supply outlet and the flood-level rim of the receiving fixture, preventing both backpressure and backsiphonage.
- RPZ assembly
- A reduced pressure zone backflow preventer with two check valves and a relief valve that discharges if pressure reverses, protecting against both backpressure and backsiphonage.
- Storage tank turnover
- Tank volume in million gallons divided by average daily demand in million gallons per day gives turnover time in days. Long turnover ages water and depletes disinfectant residual.
- Pipe haunch compaction
- Backfill placed and compacted in lifts around the lower sides of a pipe to support it and prevent ovaling, joint deflection, and settlement before the rest of the trench is filled.
- Minimum distribution residual
- A detectable disinfectant residual must be maintained throughout the distribution system; a common target is at least 0.2 mg/L free chlorine at the farthest sampling point.
- BOD5 definition
- Five-day biochemical oxygen demand measured at 20 degrees Celsius, estimating biodegradable organic matter consumed by microorganisms. Carbonaceous BOD excludes nitrogenous oxygen demand.
- F/M ratio
- Food to microorganism ratio: pounds of BOD applied per day divided by pounds of MLSS under aeration. Low F/M means long sludge age, favoring nitrification.
- MCRT formula
- Mean cell residence time in days equals pounds of MLSS in aeration divided by pounds of solids leaving daily through wasting plus effluent suspended solids.
- Sludge volume index
- SVI in mL/g equals the 30-minute settled sludge volume in mL/L times 1000 divided by MLSS in mg/L. Values above about 150 indicate poor settling and bulking.
- Nitrification oxygen demand
- Oxidizing ammonia to nitrate consumes about 4.6 mg of oxygen per mg of ammonia nitrogen and destroys roughly 7.1 mg/L alkalinity as calcium carbonate per mg of nitrogen.
- Secondary clarifier solids loading
- Solids loading rate in pounds per day per square foot equals flow plus return flow times MLSS times 8.34, divided by clarifier surface area. Overflow rate uses influent flow only.
- Anaerobic digester gas
- Volatile solids destruction in a heated, mixed anaerobic digester produces gas that is roughly 60 to 65 percent methane, with carbon dioxide making up most of the remainder.
- Fecal coliform limit
- Typical secondary treatment limit: monthly geometric mean of 200 colony-forming units per 100 mL, with no sample exceeding 400 per 100 mL.
- RAS and wasting control
- Return activated sludge rate controls MLSS concentration in the aeration basin, while the wasting rate controls mean cell residence time. More wasting lowers MCRT and MLSS.
- Manning's equation
- Velocity equals 1.486 divided by roughness n, times hydraulic radius raised to two-thirds, times slope raised to one-half. Hydraulic radius is flow area divided by wetted perimeter.
- Self-cleansing velocity
- A minimum design velocity of about 2 feet per second at design flow, keeping solids suspended and moving. Slower flow lets grit and solids deposit and cause blockages.
- Infiltration versus inflow
- Infiltration is groundwater entering through pipe defects and joints. Inflow is direct stormwater entering through downspouts, sump pumps, and manhole covers.
- Surcharge and SSO
- Surcharge is flow exceeding pipe capacity that raises the hydraulic grade line above the crown. If it reaches manholes or backups, a sanitary sewer overflow results.
- Confined space testing order
- Before sewer entry, test for oxygen (19.5 to 23.5 percent), flammable gas as LEL, hydrogen sulfide, and carbon monoxide, then monitor continuously during the entry.
- Smoke testing purpose
- Blowing smoke into a sewer section locates inflow sources and illegal connections where smoke escapes from roofs, downspouts, yard drains, or cracked pipe.
- Lift station wet well cycling
- Pump cycling frequency depends on wet well volume between lead and lag pump levels and inflow rate. Too little storage causes short cycling that overheats and damages motors.