HKIE Professional Assessment - Control, Automation & Instrumentation Discipline key terms
HKIE Professional Assessment - Control, Automation & Instrumentation Discipline · Get comfortable with the vocabulary.
- Negative feedback
- Related: Proportional-integral-derivative (PID) control, Loop tuning
A control arrangement in which the measured output is subtracted from the setpoint to produce an error signal that drives the controller, reducing deviation and making the loop self-correcting.
- Proportional-integral-derivative (PID) control
- Related: Negative feedback, Integral windup, Loop tuning
A control algorithm that combines a term proportional to the current error, a term integrating past error, and a term anticipating error trend, giving fast response with offset removal and damping.
- Integral windup
- Related: Proportional-integral-derivative (PID) control, Bumpless transfer
The condition where the integral term accumulates while the final element is saturated, so the controller output overshoots badly when the error finally reverses; prevented by anti-windup limits or back-calculation.
- Bumpless transfer
- Related: Integral windup, Cascade control
A technique that aligns controller output with the manipulated variable at the moment of switching between manual and automatic, or between cascade modes, so the final element does not jump.
- Cascade control
- Related: Bumpless transfer, Feedforward control
A structure where a primary controller's output becomes the setpoint of a faster secondary controller, isolating the main process from disturbances in an inner loop such as flow or valve position.
- Feedforward control
- Related: Cascade control, Dead time
Control that acts on a measured disturbance before it affects the controlled variable, using a process model to compute corrective action; it complements rather than replaces feedback correction.
- Dead time
- Related: Loop tuning, Process gain
The transport delay between a change at the controller output and the first detectable response in the measurement; large dead time limits achievable loop gain and stability.
- Process gain
- Related: Dead time, Loop tuning
The ratio of steady-state change in the measured variable to a unit change in controller output, indicating how strongly the process responds and therefore how much controller gain is tolerable.
- Loop tuning
- Related: Proportional-integral-derivative (PID) control, Dead time
Selecting controller gain, integral time and derivative time so the loop meets stability and response requirements; open-loop reaction-curve and closed-loop ultimate-gain methods are common starting points.
- Phase margin
- Related: Loop tuning, Negative feedback
The amount by which open-loop phase exceeds minus 180 degrees at the gain crossover frequency; it indicates relative stability and tolerance to delay in a feedback loop.
- Split-range control
- Related: Cascade control, Control valve fail-safe action
Coordinating two final elements so one handles the lower half of the controller output and the other the upper half, used for heating/cooling or for sequenced valve capacity.
- Instrumentation symbol standards
- Related: Piping and instrumentation diagram (P&ID), Loop (control loop)
Agreed conventions, notably the ISA-5.1 instrument identification and loop diagram scheme, that give every tag a function letter code and consistent graphical representation on P&IDs.
- Loop (control loop)
- Related: Piping and instrumentation diagram (P&ID), Instrumentation symbol standards
The complete set of field instrument, wiring or network, controller function and final element that together regulates one controlled variable; its boundaries define testing and documentation scope.
- Piping and instrumentation diagram (P&ID)
- Related: Instrumentation symbol standards, Loop (control loop)
A schematic showing process equipment, piping, instruments with tag numbers, and control loops; it is the master reference for instrument scope, interlock logic and commissioning checks.
- Transmitter
- Related: Two-wire loop, Measurement uncertainty
A field device that converts a sensor signal into a standardised output, commonly 4-20 mA or a digital protocol, for transmission to a control system or indicator.
- Two-wire loop
- Related: Transmitter, Intrinsic safety
A wiring arrangement in which a single pair carries both the 24 V DC supply and the 4-20 mA signal, with the transmitter regulating loop current to represent the measurement.
- Live zero
- Related: Two-wire loop, Transmitter
The practice of representing zero measurand by a nonzero signal such as 4 mA, so that a broken wire or dead transmitter reads below zero and is distinguishable from a genuine zero value.
- Measurement uncertainty
- Related: Calibration traceability, Accuracy versus precision
A quantified statement of the range within which the true value lies, combining contributions from calibration reference, repeatability, drift, installation effects and environment, usually at a stated confidence level.
- Accuracy versus precision
- Related: Measurement uncertainty, Calibration traceability
Accuracy describes closeness to the true value while precision describes repeatability of successive readings; a device can be precise yet consistently offset and therefore inaccurate.
- Calibration traceability
- Related: Measurement uncertainty, Calibration certificate
An unbroken chain of comparisons, each with stated uncertainty, linking the instrument under test through working and reference standards to a national or international metrology standard.
- Calibration certificate
- Related: Calibration traceability, Loop (control loop)
A record stating the instrument identity, test points, as-found and as-left readings, reference standard used, environmental conditions and uncertainty, supporting traceability and audit requirements.
- Orifice plate and differential pressure flow
- Related: Transmitter, Measurement uncertainty
A flow measurement method where a restriction creates a pressure drop related to flow by a square-root law, requiring square-root extraction and attention to straight pipe runs and tap locations.
- Coriolis mass flowmeter
- Related: Orifice plate and differential pressure flow, Measurement uncertainty
A meter that vibrates a tube and measures the phase shift caused by mass flow, giving direct mass flow and density; it is largely independent of fluid profile and conductivity.
- Radar level measurement
- Related: Transmitter, Measurement uncertainty
Non-contact level measurement using time-of-flight of microwave reflections from the product surface, affected by dielectric constant, foam, and false echoes requiring suppression mapping.
- Thermocouple and resistance temperature detector (RTD)
- Related: Transmitter, Two-wire loop
Two common temperature sensors: a thermocouple generates a small voltage at a junction of dissimilar metals, while an RTD changes resistance with temperature and is generally more stable and linear.
- Programmable logic controller (PLC) scan cycle
- Related: Ladder logic, Distributed control system (DCS)
The repeating sequence of reading inputs, executing the user program, and updating outputs; scan time affects response to fast events and must suit interlock timing requirements.
- Ladder logic
- Related: Programmable logic controller (PLC) scan cycle, Cause and effect matrix
A graphical programming language representing relay contacts and coils, standardised in IEC 61131-3, widely used for discrete interlocks and motor control because electricians read it easily.
- Distributed control system (DCS)
- Related: Programmable logic controller (PLC) scan cycle, Supervisory control and data acquisition (SCADA)
An integrated architecture of controllers, operator stations and I/O distributed around a plant, optimised for continuous modulating control, history and alarm management rather than fast discrete interlocking.
- Supervisory control and data acquisition (SCADA)
- Related: Distributed control system (DCS), Remote terminal unit (RTU)
A system that gathers telemetry from remote sites and issues commands from a central master station, typically over wide-area communications, with emphasis on visibility rather than local loop control.
- Remote terminal unit (RTU)
- Related: Supervisory control and data acquisition (SCADA), Industrial control system (ICS) cybersecurity
Rugged field device at a remote site that acquires inputs, stores data, executes local logic and communicates with a SCADA master, often using low-bandwidth or intermittent links.
- Cause and effect matrix
- Related: Safety integrity level (SIL), Safety instrumented function (SIF)
A table cross-referencing each initiating cause with the resulting outputs and actions, used to specify, test and document interlock and shutdown behaviour unambiguously.
- Safety instrumented function (SIF)
- Related: Safety integrity level (SIL), Safety instrumented system (SIS)
A defined protective action, with a specified integrity level, that brings the process to a safe state when a detected condition exceeds limits; each SIF is implemented by a safety instrumented system.
- Safety instrumented system (SIS)
- Related: Safety instrumented function (SIF), Safety integrity level (SIL), Proof test
The collection of sensors, logic solver and final elements that executes safety instrumented functions independently of the basic process control system, designed and maintained to a target integrity.
- Safety integrity level (SIL)
- Related: Safety instrumented function (SIF), Proof test, Functional safety lifecycle
A discrete target measure of risk reduction assigned to a safety function, expressed as a range of probability of failure on demand or failure rate, with requirements on hardware, diagnostics and process safety management.
- Proof test
- Related: Safety instrumented system (SIS), Safety integrity level (SIL)
A periodic test that reveals undetected dangerous failures in a safety function and restores its integrity, with test interval and coverage directly affecting achieved probability of failure on demand.
- Functional safety lifecycle
- Related: Safety instrumented function (SIF), Safety integrity level (SIL)
The staged process from hazard and risk assessment through safety requirements specification, design, installation, validation, operation and decommissioning, with verification and documentation at each stage.
- Intrinsic safety
- Related: Hazardous area classification, Two-wire loop
A protection concept limiting energy in hazardous-area circuits so that no spark or hot surface can ignite the atmosphere, using barriers or galvanic isolators and entity or system parameter checks.
- Hazardous area classification
- Related: Intrinsic safety, Explosion protection (flameproof enclosure)
The zoning of areas by likelihood and duration of flammable atmosphere, together with gas or dust group and temperature class, which determines permitted apparatus marking and installation methods.
- Explosion protection (flameproof enclosure)
- Related: Hazardous area classification, Intrinsic safety
A protection method in which an enclosure contains any internal ignition without transmitting flame to the surrounding atmosphere and keeps surface temperatures below the class limit.
- Foundation Fieldbus and PROFIBUS
- Related: Industrial Ethernet, Terminator and segment power
Digital fieldbus standards replacing point-to-point wiring: Foundation Fieldbus supports distributed function blocks in devices, while PROFIBUS DP is widely used for discrete and drive communication.
- Industrial Ethernet
- Related: Defence in depth (OT security), Foundation Fieldbus and PROFIBUS
Ethernet adapted for plant use with rugged cabling, deterministic protocols and redundancy, carrying controller, HMI and drive traffic; network topology and segmentation strongly affect availability.
- Defence in depth (OT security)
- Related: Industrial demilitarised zone (DMZ), Industrial control system (ICS) cybersecurity
Layering technical, procedural and physical controls across zones and conduits so that compromise of one layer does not expose the whole operational technology estate, following IEC 62443 principles.
- Industrial demilitarised zone (DMZ)
- Related: Defence in depth (OT security), Industrial control system (ICS) cybersecurity
A buffer network between plant control networks and enterprise IT that terminates and inspects traffic, hosts replicated data, and prevents direct connections across the boundary.
- Industrial control system (ICS) cybersecurity
- Related: Defence in depth (OT security), Industrial demilitarised zone (DMZ)
Protecting control systems from unauthorised access and disruption while preserving availability of physical processes, requiring asset inventory, patching strategy, access control and incident response.
- Control valve flow characteristic
- Related: Control valve sizing (Cv), Control valve fail-safe action
The relationship between valve opening and flow capacity, commonly equal-percentage or linear, chosen so installed characteristic combined with process and piping effects gives acceptable loop gain.
- Control valve sizing (Cv)
- Related: Control valve flow characteristic, Cavitation and flashing
Selecting valve capacity so it passes design flow at the available pressure drop with adequate margin, avoiding excessive oversizing that causes poor low-lift control and instability.
- Control valve fail-safe action
- Related: Control valve flow characteristic, Safety instrumented function (SIF)
The spring-driven position a valve takes on loss of air or signal, air-to-open or air-to-close, chosen so the process fails safe while respecting the safety function's required direction.
- Cavitation and flashing
- Related: Control valve sizing (Cv), Control valve flow characteristic
Liquid flow conditions where pressure falls below vapour pressure: flashing stays vapour downstream, while cavitation collapses bubbles and causes noise, vibration and erosion, requiring different valve selection.
- Valve positioner
- Related: Control valve fail-safe action, Loop tuning
A device that compares actuator travel with the control signal and adjusts air supply to reduce positioning error, improving response to friction and packing load.
- Building management system (BMS)
- Related: BACnet, Demand-controlled ventilation
A supervisory system monitoring and controlling building services such as air handling, chillers, lighting and energy metering, usually integrating multiple proprietary protocols through gateways.
- BACnet
- Related: Building management system (BMS), Demand-controlled ventilation
An open building automation protocol standardised internationally, defining objects, services and network layers so controllers and workstations from different vendors can interoperate.
- Demand-controlled ventilation
- Related: Building management system (BMS), BACnet
Ventilation control that adjusts fresh-air quantity to measured occupancy indicators such as carbon dioxide, reducing energy while maintaining indoor air quality.
- Project quality plan
- Related: Factory acceptance test (FAT) and site acceptance test (SAT), Commissioning
A project document defining responsibilities, inspection and test activities, hold points, acceptance criteria and records needed to demonstrate that delivered work meets specified requirements.
- Factory acceptance test (FAT) and site acceptance test (SAT)
- Related: Commissioning, Project quality plan
Staged verification of a control system: FAT proves functionality at the vendor's works against an agreed procedure, and SAT confirms correct operation after installation and integration on site.
- Commissioning
- Related: Factory acceptance test (FAT) and site acceptance test (SAT), Project quality plan
The structured process of checking, energising, testing and proving installed systems, including loop checks and interlock tests, before handover and operation.
- Hazard and risk assessment
- Related: Safety instrumented function (SIF), Functional safety lifecycle
A structured study identifying hazards, estimating consequence and likelihood, and defining risk reduction measures, providing the basis for safety requirements and design decisions.
- Alarm management
- Related: Distributed control system (DCS), Management of change (MOC)
The disciplined design and review of alarms against rationalisation criteria so that operators receive timely, meaningful and prioritised alerts rather than an unmanageable flood.
- Management of change (MOC)
- Related: Alarm management, Commissioning
A controlled process for reviewing, approving, implementing and recording modifications to plant, control systems or procedures so that hazards and documentation stay aligned with the as-built state.
- Professional code of conduct
- Related: Management of change (MOC), Duty of care in design
The ethical obligations of an engineering institution member, including honesty, competence, public safety, avoiding conflicts of interest and reporting matters that endanger people or the environment.
- Duty of care in design
- Related: Professional code of conduct, Hazard and risk assessment
The professional and legal obligation to exercise reasonable skill so that designed systems are safe to construct, operate and maintain, including foreseeable misuse and lifecycle considerations.