- Latent heat of vaporization
- Related: Evaporator, Superheat
The quantity of heat absorbed when a liquid changes to vapor at constant temperature and pressure, without any change in temperature. In a heat pump this heat is absorbed in the evaporator.
- Sensible heat
- Related: Total capacity, Dry-bulb temperature
Heat that changes the temperature of a substance without changing its state. In air conditioning it is the portion of capacity that lowers or raises dry-bulb temperature.
- Evaporator
- Related: Superheat, Latent heat of vaporization
The indoor coil in heating mode and outdoor coil in cooling mode where low-pressure refrigerant boils and absorbs heat from the surrounding air, producing the cooling or heating effect.
- Condenser
- Related: Subcooling, Reversing valve
The coil where high-pressure refrigerant vapor rejects heat to the surrounding air and condenses to liquid. In heating mode this is the indoor coil.
- Compressor
- Related: Metering device, Compression ratio
The pump that raises refrigerant pressure and temperature, moving vapor from the low-side evaporator to the high-side condenser. It is the component that creates the pressure difference driving the whole cycle.
- Metering device
- Related: Superheat, Evaporator
A fixed orifice, piston, or thermostatic expansion valve that drops refrigerant pressure between the condenser and evaporator and regulates how much liquid refrigerant enters the evaporator.
- Superheat
- Related: Subcooling, Metering device
The number of degrees a refrigerant vapor is above its saturation temperature at a given pressure. Measured at the evaporator outlet, it confirms the coil is fully flooded with liquid without carrying liquid back to the compressor.
- Subcooling
- Related: Superheat, Condenser
The number of degrees a liquid refrigerant is below its saturation temperature at a given pressure. Measured at the condenser outlet, it indicates how much liquid is stacked in the condenser and verifies charge on TXV systems.
- Saturation temperature
- Related: Superheat, Subcooling
The temperature at which a refrigerant boils or condenses at a specific pressure. On a pressure-temperature chart, it is the temperature read straight across from a given pressure.
- Compression ratio
- Related: Compressor, Suction pressure
Absolute discharge pressure divided by absolute suction pressure. High ratios raise discharge temperature and reduce capacity, and are a common reason a compressor overheats or trips on overload.
- Reversing valve
- Related: Defrost cycle, Condenser
A four-way solenoid-operated valve that swaps the evaporator and condenser roles by redirecting discharge and suction gas, allowing one refrigerant circuit to both heat and cool.
- Defrost cycle
- Related: Reversing valve, Outdoor fan
A timed or demand-initiated sequence that temporarily reverses the cycle or stops the outdoor fan to melt frost from the outdoor coil, then returns the unit to normal heating.
- Auxiliary heat
- Related: Balance point, Emergency heat
Supplemental electric resistance or fossil-fuel heat that energizes when the heat pump cannot meet the load, such as during defrost or very low outdoor temperatures.
- Balance point
- Related: Auxiliary heat, Emergency heat
The outdoor temperature at which heat pump capacity exactly equals the building heat loss. Below it, supplemental heat must make up the difference to hold setpoint.
- Emergency heat
- Related: Auxiliary heat, Balance point
A mode in which the compressor is locked out and only supplemental resistance heat is used, typically selected manually when the compressor or outdoor unit has failed.
- Crankcase heater
- Related: Compressor, Accumulator
A small resistance heater wrapped around or inserted in the compressor sump that keeps oil warm so refrigerant does not migrate and dilute the oil during the off cycle.
- Accumulator
- Related: Crankcase heater, Superheat
A vessel on the suction line of some heat pumps that traps liquid refrigerant and oil and meters them back to the compressor as vapor, protecting it from liquid slugging.
- Contactor
- Related: Defrost control board, Lockout
A heavy-duty relay whose coil is energized by the thermostat or control board to close high-amperage line-voltage contacts feeding the compressor or outdoor fan motor.
- Defrost control board
- Related: Defrost cycle, Reversing valve
The electronic control that monitors coil temperature and run time, initiates and terminates defrost, and energizes the reversing valve and auxiliary heat during defrost.
- Low-voltage thermostat
- Related: Contactor, Defrost control board
A control operating typically on 24 volts that switches compressor, reversing valve, fan, and auxiliary heat circuits through the indoor unit's control board and terminal strip.
- Line set
- Related: Suction line, Liquid line
The pair of copper tubes connecting the outdoor unit to the indoor coil, consisting of an insulated larger suction line and a smaller liquid line.
- Suction line
- Related: Line set, Superheat
The larger, insulated vapor line carrying low-pressure refrigerant gas from the evaporator back to the compressor. It must be sized and insulated to limit pressure drop and prevent condensation.
- Liquid line
- Related: Filter drier, Subcooling
The smaller line carrying high-pressure liquid refrigerant from the condenser to the metering device. A liquid-line filter drier is installed here to remove moisture and debris.
- Filter drier
- Related: Liquid line, Metering device
A device in the liquid line containing a desiccant and screen that traps moisture, acid, and particulate matter to protect the metering device and compressor.
- Nitrogen purge
- Related: Filter drier, Evacuation
Flowing dry nitrogen through piping while brazing to displace oxygen and prevent internal oxidation, which would otherwise form scale that contaminates the system.
- Evacuation
- Related: Micron gauge, Weigh-in charging
Pulling a deep vacuum with a pump to remove air, nitrogen, and moisture from the system before charging. A standing vacuum decay test confirms the system is leak-free and dry.
- Micron gauge
- Related: Evacuation, Weigh-in charging
An electronic vacuum instrument that reads absolute pressure in microns, used to confirm evacuation below about 500 microns and to verify the vacuum holds.
- Weigh-in charging
- Related: Subcooling, Superheat
Adding refrigerant by weight using a scale and the manufacturer's nameplate charge or line-set adjustment, the most accurate method for systems with fixed metering devices.
- Target subcooling
- Related: Subcooling, Weigh-in charging
The manufacturer-specified subcooling value used to set charge on TXV systems. Measured subcooling above target means overcharge; below target means undercharge.
- Target superheat
- Related: Superheat, Dry-bulb temperature
A value calculated from indoor wet-bulb and outdoor dry-bulb temperatures, used to set charge on fixed-orifice systems when conditions fall outside the charging chart's normal range.
- Dry-bulb temperature
- Related: Wet-bulb temperature, Total capacity
Air temperature measured by an ordinary thermometer, unaffected by moisture content. It is used with wet-bulb to determine airflow and system capacity.
- Wet-bulb temperature
- Related: Dry-bulb temperature, Target superheat
The temperature of air measured with a wetted thermometer bulb, reflecting moisture content and evaporative cooling potential. It is essential for calculating target superheat and airflow.
- External static pressure
- Related: Total external static pressure, Temperature rise
The resistance to airflow measured in inches of water column across the air handler, including ductwork and accessories. It is used with a fan table to determine delivered airflow.
- Temperature rise
- Related: External static pressure, Total capacity
The difference between return-air and supply-air dry-bulb temperatures in heating mode. Combined with airflow, it verifies that the unit is delivering rated heating capacity.
- Total capacity
- Related: Sensible heat, Wet-bulb temperature
The combined sensible and latent heat a system moves, expressed in Btuh. It is verified in the field using airflow and the enthalpy difference across the coil.
- Superheat method
- Related: Target superheat, Subcooling
A charging and diagnostic procedure that compares measured superheat with a target derived from indoor wet-bulb and outdoor dry-bulb, used on fixed-orifice systems and to check TXV operation.
- Lockout
- Related: High-pressure switch, Low-pressure switch
A control state in which the unit is prevented from running, often after repeated safety trips such as high-pressure or low-pressure switches, requiring manual or automatic reset.
- High-pressure switch
- Related: Low-pressure switch, Lockout
A safety control that opens the compressor circuit when discharge pressure exceeds a set limit, protecting against overcharge, restricted airflow, or a failed condenser fan.
- Low-pressure switch
- Related: High-pressure switch, Lockout
A safety control that opens the compressor circuit when suction pressure falls too low, indicating loss of charge, a restriction, or low ambient operation.
- Section 608 certification
- Related: Recovery machine, Filter drier
The EPA credential required for technicians who service, repair, or dispose of appliances containing regulated refrigerants, with Type II covering most residential split heat pumps.
- Recovery machine
- Related: Section 608 certification, Evacuation
Equipment that removes refrigerant from a system into a recovery cylinder for reuse, recycling, or disposal, required before opening a circuit or scrapping equipment.