Boiler horsepower
A unit of boiler capacity equal to 33,475 Btu/h, roughly the heat needed to evaporate 15.65 kg of water per hour at atmospheric pressure.
MAWP
Maximum allowable working pressure, the highest gauge pressure at which a boiler may be operated, stamped on the nameplate and set as the safety valve limit.
Latent heat of vaporization
The heat absorbed when a unit mass changes from saturated liquid to saturated vapor at constant temperature and pressure; about 2,257 kJ/kg at 100 °C.
Superheated steam
Steam heated above its saturation temperature at a given pressure; it carries no moisture and gives up sensible heat as it cools.
LMTD
Logarithmic mean temperature difference, the effective driving temperature difference for heat transfer in a boiler or heat exchanger, used in Q = U·A·LMTD.
Fire-tube boiler
A boiler in which hot combustion gases pass through tubes surrounded by water; limited to moderate pressure and capacity, common in packaged heating plants.
Water-tube boiler
A boiler in which water circulates inside tubes surrounded by hot gas; used for high pressure and large capacity in utility and industrial service.
Economizer
A heat exchanger that preheats boiler feedwater using heat from the flue gas before the gas leaves the stack, raising overall thermal efficiency.
Steam drum
The upper pressure vessel that separates steam from water, holds the water level, and provides space for steam release and chemical addition.
Safety valve capacity
The maximum mass flow a safety valve can discharge at its set pressure; it must equal or exceed the boiler's maximum steam-generating capacity.
Excess air
The percentage of combustion air supplied above the theoretical stoichiometric amount; typically 10–20% for gas firing to ensure complete combustion.
Turndown ratio
The ratio of a burner's maximum firing rate to its minimum stable firing rate; a 10:1 burner can fire from full rate down to one-tenth.
Pre-purge
A timed period of air flow through the furnace before ignition that removes any accumulated combustible gas, typically 15–60 seconds.
Flame scanner
A sensor, usually ultraviolet or a flame rod, that proves the presence of flame; loss of signal trips the fuel valve within the flame-failure response time.
Makeup water
Treated water added to the boiler to replace steam and condensate losses; it is softened and demineralized to prevent scale and corrosion.
Deaerator
A vessel that heats feedwater and strips dissolved oxygen and carbon dioxide, reducing corrosion in the boiler and condensate system.
Scale
A hard deposit of calcium and magnesium salts on boiler surfaces that insulates tubes, reduces heat transfer, and can cause overheating and tube failure.
Carryover
The entrainment of boiler water droplets and dissolved solids into the steam, detected by high conductivity in condensed steam and controlled by blowdown.
Low-water fuel cutoff
A safety device that shuts off fuel to the burner when the water level falls below the safe limit, preventing overheating and tube damage.
Burner management system
The control system that sequences pre-purge, ignition, main flame, and shutdown, and interlocks all safety devices to prevent unsafe firing.
High gas pressure switch
A safety switch that trips the burner when fuel gas pressure rises above its set point, protecting the burner and fuel train from overpressure.
Gauge glass
A transparent tube connected to the boiler at the steam and water space that shows the water level; its normal level mark is the operating datum.
Bottom blowdown
Opening the mud drum valve to discharge sludge and sediment; done at low fire with the boiler under steady load and the valve fully opened and closed.
Priming
A condition in which boiler water is carried over into the steam line, often caused by high water level, foaming, or rapid load changes.
Hydrostatic test
A pressure test with water at 1.5 times MAWP for new boilers, with safety valves removed or gagged, to verify strength and tightness.
Ultrasonic thickness test
A non-destructive method that measures tube and shell wall thickness to detect corrosion or erosion loss and determine whether replacement is required.
Flue gas analysis
Measurement of oxygen, carbon monoxide, carbon dioxide, and stack temperature used to set excess air and calculate combustion efficiency.
ASME Section I
The section of the ASME Boiler and Pressure Vessel Code that sets rules for construction of power boilers, including materials, design, and stamping.
ASME Section IV
The ASME code section covering construction of heating boilers, which operate at lower pressure and temperature than power boilers.
ASME CSD-1
The ASME standard for controls and safety devices on automatically fired boilers, covering interlocks, flame safeguards, and limit controls.
NFPA 85
The National Fire Protection Association standard for boiler and combustion systems hazards, covering fuel trains, purging, and burner safety.
Lockout/tagout
A procedure that isolates and locks energy sources, including fuel, electricity, and steam, before maintenance to prevent unexpected startup or release.