IA Electrician study materials
IA Electrician study resources

IA Electrician key terms

IA Electrician · Get comfortable with the vocabulary.

Ohm's Law

The relationship in a DC circuit where voltage equals current multiplied by resistance (E = I × R). Knowing any two values lets you calculate the third, making it basic to troubleshooting and sizing.

Related: Impedance, Voltage Drop
Impedance

The total opposition a circuit offers to alternating current, combining resistance with inductive and capacitive reactance. Measured in ohms and written as Z, it determines current flow in AC systems.

Related: Ohm's Law, Power Factor
Power Factor

The ratio of true power in watts to apparent power in volt-amperes in an AC circuit. A value of one means a purely resistive load; lower values mean more current is needed for the same useful work.

Related: Impedance
Ampacity

The maximum current a conductor can carry continuously under stated conditions without exceeding its temperature rating. Values come from code tables and are adjusted for ambient temperature and the number of current-carrying conductors.

Related: Derating, Conductor Insulation Rating
Derating

Reducing the allowable current of conductors or devices below the table value to account for real conditions, such as high ambient temperature, more than three current-carrying conductors in a raceway, or unusual installation circumstances.

Related: Ampacity, Conduit Fill
Circular Mil

A unit of area equal to a circle one-thousandth of an inch in diameter, used to express conductor cross section. One thousand circular mils equals one kcmil, and larger areas mean lower resistance.

Related: Ampacity, Voltage Drop
Voltage Drop

The loss of voltage along circuit conductors caused by their resistance and reactance as current flows. Excessive drop leaves equipment with low voltage and can cause poor operation or overheating.

Related: Circular Mil, Ampacity
Conductor Insulation Rating

The maximum temperature in degrees Celsius that a conductor's insulation can withstand continuously, such as 60, 75, or 90 degrees. This rating sets the ampacity column used and limits termination temperature.

Related: Ampacity, Derating
Branch Circuit

The circuit conductors between the final overcurrent device protecting the circuit and the outlets or equipment it supplies. Branch circuits feed receptacles, lighting, and individual appliances.

Related: Feeder, Circuit Breaker
Feeder

All circuit conductors between the service equipment, a separately derived source, or another supply source and the final branch-circuit overcurrent devices. Feeders supply panelboards and distribution points.

Related: Branch Circuit, Service Drop
Service Drop

The overhead conductors running from the utility's last pole or transformer to the service point at the building. Service-entrance conductors begin where the drop ends.

Related: Feeder, Grounded Conductor
Grounded Conductor

A circuit conductor intentionally connected to earth, commonly called the neutral. It carries return current during normal operation and must be identified by white or gray finish.

Related: Polarity, Grounding Electrode
Continuous Load

A load expected to operate at maximum current for three hours or longer. Branch-circuit and overcurrent device sizing must generally include 125 percent of a continuous load.

Related: Branch Circuit, Demand Factor
Raceway

An enclosed channel of metal or nonmetallic material designed to hold wires, cables, or busbars. Examples include rigid conduit, electrical metallic tubing, and PVC conduit.

Related: Conduit Fill, Supporting and Securing
Conduit Fill

The portion of a raceway's cross section occupied by conductors. Codes limit fill so wires can be pulled without damage and heat can dissipate properly.

Related: Raceway, Derating
Nonmetallic-Sheathed Cable

A factory assembly of insulated conductors covered by an overall nonmetallic jacket, used mainly in dry interior locations such as dwellings. Type NM-B is a common example.

Related: Supporting and Securing, Knockout
Supporting and Securing

Code requirements for fastening cables and raceways to the building structure and holding them in place along the run at specified intervals, preventing strain and damage.

Related: Raceway, Nonmetallic-Sheathed Cable
Box Fill

The calculated volume of an outlet, device, or junction box compared with the space needed by conductors, devices, fittings, and grounding. It prevents overcrowding that could damage insulation.

Related: Knockout, Conduit Fill
Knockout

A removable tab or precut opening in the wall of a box or enclosure that is punched out to accept a conduit or cable connector. Unused openings must be closed.

Related: Box Fill, Raceway
Grounding-Type Receptacle

A receptacle with a third, U-shaped slot connected to the equipment grounding conductor. It provides a fault path for the metal enclosures of cord-and-plug connected equipment.

Related: Equipment Grounding Conductor, Ground Fault
Switch Leg

The conductor running from a switch to the controlled outlet or luminaire. It carries switched power rather than constant unswitched power.

Related: Branch Circuit, Polarity
Polarity

Correct identification of which circuit conductor is grounded versus ungrounded, so that screw shells and identified terminals are wired as intended. Reversed polarity is a shock and safety hazard.

Related: Grounded Conductor, Switch Leg
Arc-Fault Circuit Interrupter

A device that senses the signature of dangerous arcing in branch-circuit wiring and opens the circuit to prevent fire. AFCIs are required for many dwelling branch circuits.

Related: Circuit Breaker, Overcurrent Protective Device
Circuit Breaker

An overcurrent device that opens automatically on excess current and can be reset by hand. Types include thermal-magnetic and electronic, and some include GFCI or AFCI protection.

Related: Overcurrent Protective Device, Arc-Fault Circuit Interrupter
Overcurrent Protective Device

A fuse or circuit breaker intended to open a circuit when current exceeds a chosen value for a chosen time. It protects conductors and equipment from damaging overheating.

Related: Circuit Breaker, Ampacity
Grounding Electrode

A conductive object in direct contact with the earth, such as a rod, pipe, plate, or concrete-encased electrode. It ties the electrical system's grounding point to earth.

Related: Equipment Grounding Conductor, Ground Fault
Equipment Grounding Conductor

The conductive path connecting normally non-current-carrying metal parts of equipment to the system grounding point. It lets fault current return so the overcurrent device trips.

Related: Bonding Jumper, Ground Fault
Bonding Jumper

A conductor, screw, or strap that ensures electrical continuity between metal parts that must stay at the same potential. Bonding prevents dangerous voltage differences during faults.

Related: Equipment Grounding Conductor, Grounding Electrode
Ground Fault

An unintended path of current from an ungrounded conductor to ground through a person, equipment, or the earth instead of the intended circuit. It can cause shock or fire.

Related: Equipment Grounding Conductor, Arc-Fault Circuit Interrupter
Motor Full-Load Current

The current a motor draws at its rated load and rated voltage, taken from code tables rather than the nameplate. It is the basis for sizing conductors, overcurrent devices, and disconnects.

Related: Motor Overload Protection, Disconnecting Means
Motor Overload Protection

A device that protects a motor from sustained excess current and resulting overheating by opening the circuit. It is separate from short-circuit and ground-fault protection.

Related: Motor Full-Load Current, Service Factor
Service Factor

A multiplier, often 1.15, applied to a motor's nameplate horsepower showing how much above rated load it can carry continuously under rated conditions. It affects overload protection sizing.

Related: Motor Full-Load Current, Motor Overload Protection
Disconnecting Means

A device or group of devices that can safely disconnect all circuit conductors or equipment from the supply for servicing. It must be rated for the load and readily accessible.

Related: Lockout/Tagout, Motor Full-Load Current
Hazardous (Classified) Location

An area where fire or explosion risk exists because of flammable gases, vapors, dusts, or fibers. Wiring methods and equipment there are restricted by class and division or zone.

Related: Intrinsically Safe, Raceway
Intrinsically Safe

Equipment and wiring designed so available energy and surface temperature are too low to ignite a hazardous atmosphere under normal or fault conditions. It is permitted in classified locations.

Related: Hazardous (Classified) Location
Lockout/Tagout

A safety procedure in which each energy source is shut off, locked, and tagged by the worker so equipment cannot be re-energized while someone is servicing it.

Related: Arc Flash, Disconnecting Means
Arc Flash

A sudden release of energy from an electrical arc, producing intense heat, light, pressure, and molten metal. It requires arc-rated protective equipment and safe work practices.

Related: Lockout/Tagout, Working Space
Working Space

The clear, dedicated area in front of electrical equipment that must stay unobstructed so workers can safely operate and service it. Its depth depends on voltage and conditions.

Related: Arc Flash, Panel Schedule
Panel Schedule

A chart, usually inside a panelboard door or on plans, listing each branch circuit's number, rating, and the loads it serves. It is used for balancing and identifying circuits.

Related: Branch Circuit, Demand Factor
Demand Factor

The ratio of maximum demand over a period to the total connected load. Applying it lets service and feeder conductors be sized to realistic loads rather than every load at once.

Related: Continuous Load, Panel Schedule