IAAI-FIT case studies
IAAI-FIT · Put your knowledge to work in context.
The IAAI-FIT® is one of the credentials offered by the International Association of Arson Investigators, Inc., which describes itself as the world's premiere professional association for fire, arson, and explosion investigation professionals. According to the association's own description, the FIT credential is intended for personnel who have general experience in fire scene investigation without exclusive fire investigation specialization, such as fire officer, fire marshal, and insurance adjuster. It is therefore a natural step for people whose duties bring them to fire scenes regularly but who do not investigate fires full time, and who want a recognized marker of that competence before, or instead of, pursuing the more demanding IAAI-CFI® certification. The association states that the designation is based in job performance requirements in NFPA 1021, NFPA 1033, and NFPA 1037, so candidates should expect content grounded in fire officer duties, the professional practice of fire investigation, and fire marshal responsibilities rather than in a single specialty. The IAAI-FIT case studies are 5 cases and about 3,182 words.
1Duplex Fire with Hoarding and a Reported Missing Occupant
At 02:14, Engine 3 arrives at a two-story wood-frame duplex, 1,800 square feet, with heavy smoke from the first-floor windows and a report of a missing 78-year-old man who uses a walker and sleeps in the rear bedroom. The first-floor rear bedroom is packed with newspapers and plastic totes to a depth of four feet.
713 words, about 4 min2Vehicle Fire in a Detached Garage with Aftermarket Wiring
A 2019 pickup truck burned inside a 24-foot by 30-foot detached garage. The garage has no electrical service.
631 words, about 3 min3Assembly Occupancy Inspection and a Requested Waiver
The fire marshal inspects a 4,800-square-foot restaurant and banquet hall licensed for 180 occupants. The building was constructed in 1968 and has no automatic sprinkler system.
618 words, about 3 min4Fatal Fire with a Premature Cause Determination
A 68-year-old man died in a 1,200-square-foot single-family home. Fire damage is confined to the living room, where the victim was found.
607 words, about 3 min5SCBA Low-Air Event During Overhaul
After a live-fire exercise in a concrete burn building, a firefighter's SCBA low-air alarm activates at 1,100 psi during overhaul. He had been assigned to ventilation and was working alone in a 12-foot by 16-foot room.
613 words, about 3 min