Water Efficiency and Conservation

  • WaterSense maximum flush volume for tank-type toilets is 1.28 gallons per flush (gpf); high-efficiency toilets must not exceed 1.28 gpf, and single-flush HETs commonly run 1.28 gpf while dual-flush units average about 1.1-1.2 gpf.

  • WaterSense showerheads are rated at a maximum 2.0 gallons per minute (gpm) at 80 psi; federal standards allow 2.5 gpm, so a WaterSense-labeled head saves roughly 20 percent versus the federal maximum.

  • WaterSense bathroom faucets and aerators are limited to 1.5 gpm at 60 psi; standard kitchen faucets are 2.2 gpm, and public lavatory faucets are typically 0.5 gpm.

  • Urinal flush volumes: standard 1.0 gpf, high-efficiency 0.5 gpf or less, and WaterSense urinals at 0.5 gpf; waterless urinals use a cartridge or seal liquid instead of flush water.

  • A dual-flush toilet uses a reduced flush (about 0.8-1.1 gallons) for liquid waste and a full flush (about 1.28-1.6 gallons) for solids; the effective average depends on the ratio of reduced to full flushes.

  • Peak demand estimate: fixture units from a plumbing code table are converted to probable flow (gpm) using a demand curve, not by summing fixture flows; Hunter's method underlies most code demand tables.

  • Leak detection rule of thumb: a silent toilet leak can waste 200 gallons or more per day; dye-tablet testing of the tank and a water-meter dial check with all fixtures off are standard diagnostic steps.

  • Rainwater harvesting yield estimate: annual harvest = catchment area (sq ft) x rainfall (in) x 0.623 x runoff coefficient; a 1,000 sq ft roof with 12 in annual rain and 0.85 coefficient yields about 6,350 gallons.

  • Graywater from lavatories, showers, and laundry can supply subsurface irrigation or toilet flushing where the local code allows; kitchen sink, dishwasher, and toilet water are blackwater and excluded.

Quick reference

Energy Efficiency and Renewable Energy

  • Water heater storage setpoint: 120 degrees F is the common efficiency and scald-prevention setpoint; stored water at 140 degrees F or higher requires a tempering valve to limit delivery to about 120 degrees F at fixtures.

  • Heat trap requirement: 24-inch or 6-inch vertical heat traps (or equivalent integral traps) on inlet and outlet of a storage water heater reduce standby loss by limiting convection through the pipes.

  • Tankless (demand) water heaters are rated by maximum temperature rise and flow; a unit's capacity in gpm falls as the required temperature rise increases, so cold inlet temperatures reduce delivered flow.

  • Solar domestic hot water: an SRCC OG-300 certified system rating accounts for collector, storage, and climate; a typical residential system offsets 50-75 percent of annual water heating load depending on location.

  • Solar collector sizing rule of thumb: about 20 sq ft of flat-plate collector per person for a 50-60 percent solar fraction in moderate climates; storage is roughly 1.5-2 gallons per sq ft of collector.

  • Heat pump water heaters (HPWH) typically have a coefficient of performance (COP) of 2-3.5, meaning they move 2-3.5 units of heat per unit of electricity; they cool and dehumidify the space they draw air from.

  • Recirculation systems: a dedicated return line with a pump and aquastat or timer reduces waiting time and wasted water; an on-demand (demand-controlled) system avoids the standby losses of continuous recirculation.

  • Pipe insulation thermal rule: insulate the first 6 feet of hot and cold piping from a storage water heater and all accessible hot piping; insulating cold lines prevents condensation and protects against freezing.

Quick reference

Green Building Codes and Standards

  • The Uniform Plumbing Code (UPC) and International Plumbing Code (IPC) are the two model plumbing codes in the US; green plumbing provisions appear in the Uniform Solar, Hydronics and Geothermal Code and in state green building codes.

  • WaterSense is a voluntary EPA labeling program; labeled products meet efficiency and performance criteria and are often referenced by local green codes and utility rebate programs.

  • LEED v4.1 Water Efficiency credits include Outdoor Water Use Reduction, Indoor Water Use Reduction, and Water Metering; indoor reduction is measured against a calculated baseline using fixture flow rates and occupancy.

  • The International Green Construction Code (IgCC) and ASHRAE 189.1 set mandatory and prescriptive green requirements, including water-use reduction percentages and metering of large water uses.

  • CALGreen (California Green Building Standards Code) mandates 20 percent indoor water use reduction over the 2007 baseline for new construction, with additional tiers for voluntary higher performance.

  • Green plumbing code provisions commonly require separate metering for indoor and outdoor water, sub-metering for buildings over a threshold size, and pressure-reducing valves where supply pressure exceeds 80 psi.

  • Commissioning of plumbing systems verifies design flow rates, pressure, water heater performance, and controls; it is a prerequisite or credit in several green rating systems.

  • Backflow prevention and cross-connection control are prerequisites for any recycled or harvested water system; reduced-pressure-zone assemblies protect potable supply from contamination.

Quick reference

Sustainable Plumbing Systems and Materials

  • Rainwater and graywater systems require a cross-connection control assembly and clearly labeled nonpotable piping (often purple for reclaimed water) to prevent contamination of the potable supply.

  • Onsite water reuse system components typically include a storage tank, filtration, disinfection (UV or chlorine), and a pump; treatment level depends on the intended end use, with subsurface irrigation needing less than toilet flushing.

  • Pipe material selection: PEX and CPVC are common for hot and cold distribution; cast iron and PVC are used for drain, waste, and vent; copper remains common where code or local practice requires it.

  • Lead-free requirement: the Safe Drinking Water Act as amended in 2011 limits the weighted average lead content of wetted pipe, fittings, and fixtures to 0.25 percent.

  • Low-flow fixtures reduce hot water demand as well as total water use, which lowers the energy needed to heat water; the water-energy nexus means efficiency in one area supports the other.

  • Gravity-fed and low-pressure systems require careful pipe sizing; excessive velocity causes noise and erosion, and undersized drain lines cause backups, so fixture-unit tables and slope requirements must be followed.

  • Sustainable material selection considers recycled content, local sourcing, durability, and end-of-life recyclability; copper and cast iron have high recycled content and long service lives.

  • Permeable and infiltration-based stormwater practices reduce runoff and recharge groundwater; rain gardens and cisterns are common low-impact development (LID) components in plumbing-adjacent site design.

  • Pressure-reducing valves at the service entrance protect fixtures and piping from excessive pressure and reduce water waste from leaks and fixture wear.

Quick reference

Water Efficiency and Conservation

  • WaterSense maximum flush volume for tank-type toilets is 1.28 gallons per flush (gpf); high-efficiency toilets must not exceed 1.28 gpf, and single-flush HETs commonly run 1.28 gpf while dual-flush units average about 1.1-1.2 gpf.

  • WaterSense showerheads are rated at a maximum 2.0 gallons per minute (gpm) at 80 psi; federal standards allow 2.5 gpm, so a WaterSense-labeled head saves roughly 20 percent versus the federal maximum.

  • WaterSense bathroom faucets and aerators are limited to 1.5 gpm at 60 psi; standard kitchen faucets are 2.2 gpm, and public lavatory faucets are typically 0.5 gpm.

  • Urinal flush volumes: standard 1.0 gpf, high-efficiency 0.5 gpf or less, and WaterSense urinals at 0.5 gpf; waterless urinals use a cartridge or seal liquid instead of flush water.

  • A dual-flush toilet uses a reduced flush (about 0.8-1.1 gallons) for liquid waste and a full flush (about 1.28-1.6 gallons) for solids; the effective average depends on the ratio of reduced to full flushes.

  • Peak demand estimate: fixture units from a plumbing code table are converted to probable flow (gpm) using a demand curve, not by summing fixture flows; Hunter's method underlies most code demand tables.

  • Leak detection rule of thumb: a silent toilet leak can waste 200 gallons or more per day; dye-tablet testing of the tank and a water-meter dial check with all fixtures off are standard diagnostic steps.

  • Rainwater harvesting yield estimate: annual harvest = catchment area (sq ft) x rainfall (in) x 0.623 x runoff coefficient; a 1,000 sq ft roof with 12 in annual rain and 0.85 coefficient yields about 6,350 gallons.

  • Graywater from lavatories, showers, and laundry can supply subsurface irrigation or toilet flushing where the local code allows; kitchen sink, dishwasher, and toilet water are blackwater and excluded.

Quick reference

Energy Efficiency and Renewable Energy

  • Water heater storage setpoint: 120 degrees F is the common efficiency and scald-prevention setpoint; stored water at 140 degrees F or higher requires a tempering valve to limit delivery to about 120 degrees F at fixtures.

  • Heat trap requirement: 24-inch or 6-inch vertical heat traps (or equivalent integral traps) on inlet and outlet of a storage water heater reduce standby loss by limiting convection through the pipes.

  • Tankless (demand) water heaters are rated by maximum temperature rise and flow; a unit's capacity in gpm falls as the required temperature rise increases, so cold inlet temperatures reduce delivered flow.

  • Solar domestic hot water: an SRCC OG-300 certified system rating accounts for collector, storage, and climate; a typical residential system offsets 50-75 percent of annual water heating load depending on location.

  • Solar collector sizing rule of thumb: about 20 sq ft of flat-plate collector per person for a 50-60 percent solar fraction in moderate climates; storage is roughly 1.5-2 gallons per sq ft of collector.

  • Heat pump water heaters (HPWH) typically have a coefficient of performance (COP) of 2-3.5, meaning they move 2-3.5 units of heat per unit of electricity; they cool and dehumidify the space they draw air from.

  • Recirculation systems: a dedicated return line with a pump and aquastat or timer reduces waiting time and wasted water; an on-demand (demand-controlled) system avoids the standby losses of continuous recirculation.

  • Pipe insulation thermal rule: insulate the first 6 feet of hot and cold piping from a storage water heater and all accessible hot piping; insulating cold lines prevents condensation and protects against freezing.

Quick reference

Green Building Codes and Standards

  • The Uniform Plumbing Code (UPC) and International Plumbing Code (IPC) are the two model plumbing codes in the US; green plumbing provisions appear in the Uniform Solar, Hydronics and Geothermal Code and in state green building codes.

  • WaterSense is a voluntary EPA labeling program; labeled products meet efficiency and performance criteria and are often referenced by local green codes and utility rebate programs.

  • LEED v4.1 Water Efficiency credits include Outdoor Water Use Reduction, Indoor Water Use Reduction, and Water Metering; indoor reduction is measured against a calculated baseline using fixture flow rates and occupancy.

  • The International Green Construction Code (IgCC) and ASHRAE 189.1 set mandatory and prescriptive green requirements, including water-use reduction percentages and metering of large water uses.

  • CALGreen (California Green Building Standards Code) mandates 20 percent indoor water use reduction over the 2007 baseline for new construction, with additional tiers for voluntary higher performance.

  • Green plumbing code provisions commonly require separate metering for indoor and outdoor water, sub-metering for buildings over a threshold size, and pressure-reducing valves where supply pressure exceeds 80 psi.

  • Commissioning of plumbing systems verifies design flow rates, pressure, water heater performance, and controls; it is a prerequisite or credit in several green rating systems.

  • Backflow prevention and cross-connection control are prerequisites for any recycled or harvested water system; reduced-pressure-zone assemblies protect potable supply from contamination.

Quick reference

Sustainable Plumbing Systems and Materials

  • Rainwater and graywater systems require a cross-connection control assembly and clearly labeled nonpotable piping (often purple for reclaimed water) to prevent contamination of the potable supply.

  • Onsite water reuse system components typically include a storage tank, filtration, disinfection (UV or chlorine), and a pump; treatment level depends on the intended end use, with subsurface irrigation needing less than toilet flushing.

  • Pipe material selection: PEX and CPVC are common for hot and cold distribution; cast iron and PVC are used for drain, waste, and vent; copper remains common where code or local practice requires it.

  • Lead-free requirement: the Safe Drinking Water Act as amended in 2011 limits the weighted average lead content of wetted pipe, fittings, and fixtures to 0.25 percent.

  • Low-flow fixtures reduce hot water demand as well as total water use, which lowers the energy needed to heat water; the water-energy nexus means efficiency in one area supports the other.

  • Gravity-fed and low-pressure systems require careful pipe sizing; excessive velocity causes noise and erosion, and undersized drain lines cause backups, so fixture-unit tables and slope requirements must be followed.

  • Sustainable material selection considers recycled content, local sourcing, durability, and end-of-life recyclability; copper and cast iron have high recycled content and long service lives.

  • Permeable and infiltration-based stormwater practices reduce runoff and recharge groundwater; rain gardens and cisterns are common low-impact development (LID) components in plumbing-adjacent site design.

  • Pressure-reducing valves at the service entrance protect fixtures and piping from excessive pressure and reduce water waste from leaks and fixture wear.

Quick reference

Water Efficiency and Conservation

  • WaterSense maximum flush volume for tank-type toilets is 1.28 gallons per flush (gpf); high-efficiency toilets must not exceed 1.28 gpf, and single-flush HETs commonly run 1.28 gpf while dual-flush units average about 1.1-1.2 gpf.

  • WaterSense showerheads are rated at a maximum 2.0 gallons per minute (gpm) at 80 psi; federal standards allow 2.5 gpm, so a WaterSense-labeled head saves roughly 20 percent versus the federal maximum.

  • WaterSense bathroom faucets and aerators are limited to 1.5 gpm at 60 psi; standard kitchen faucets are 2.2 gpm, and public lavatory faucets are typically 0.5 gpm.

  • Urinal flush volumes: standard 1.0 gpf, high-efficiency 0.5 gpf or less, and WaterSense urinals at 0.5 gpf; waterless urinals use a cartridge or seal liquid instead of flush water.

  • A dual-flush toilet uses a reduced flush (about 0.8-1.1 gallons) for liquid waste and a full flush (about 1.28-1.6 gallons) for solids; the effective average depends on the ratio of reduced to full flushes.

  • Peak demand estimate: fixture units from a plumbing code table are converted to probable flow (gpm) using a demand curve, not by summing fixture flows; Hunter's method underlies most code demand tables.

  • Leak detection rule of thumb: a silent toilet leak can waste 200 gallons or more per day; dye-tablet testing of the tank and a water-meter dial check with all fixtures off are standard diagnostic steps.

  • Rainwater harvesting yield estimate: annual harvest = catchment area (sq ft) x rainfall (in) x 0.623 x runoff coefficient; a 1,000 sq ft roof with 12 in annual rain and 0.85 coefficient yields about 6,350 gallons.

  • Graywater from lavatories, showers, and laundry can supply subsurface irrigation or toilet flushing where the local code allows; kitchen sink, dishwasher, and toilet water are blackwater and excluded.

Quick reference

Energy Efficiency and Renewable Energy

  • Water heater storage setpoint: 120 degrees F is the common efficiency and scald-prevention setpoint; stored water at 140 degrees F or higher requires a tempering valve to limit delivery to about 120 degrees F at fixtures.

  • Heat trap requirement: 24-inch or 6-inch vertical heat traps (or equivalent integral traps) on inlet and outlet of a storage water heater reduce standby loss by limiting convection through the pipes.

  • Tankless (demand) water heaters are rated by maximum temperature rise and flow; a unit's capacity in gpm falls as the required temperature rise increases, so cold inlet temperatures reduce delivered flow.

  • Solar domestic hot water: an SRCC OG-300 certified system rating accounts for collector, storage, and climate; a typical residential system offsets 50-75 percent of annual water heating load depending on location.

  • Solar collector sizing rule of thumb: about 20 sq ft of flat-plate collector per person for a 50-60 percent solar fraction in moderate climates; storage is roughly 1.5-2 gallons per sq ft of collector.

  • Heat pump water heaters (HPWH) typically have a coefficient of performance (COP) of 2-3.5, meaning they move 2-3.5 units of heat per unit of electricity; they cool and dehumidify the space they draw air from.

  • Recirculation systems: a dedicated return line with a pump and aquastat or timer reduces waiting time and wasted water; an on-demand (demand-controlled) system avoids the standby losses of continuous recirculation.

  • Pipe insulation thermal rule: insulate the first 6 feet of hot and cold piping from a storage water heater and all accessible hot piping; insulating cold lines prevents condensation and protects against freezing.

Quick reference

Green Building Codes and Standards

  • The Uniform Plumbing Code (UPC) and International Plumbing Code (IPC) are the two model plumbing codes in the US; green plumbing provisions appear in the Uniform Solar, Hydronics and Geothermal Code and in state green building codes.

  • WaterSense is a voluntary EPA labeling program; labeled products meet efficiency and performance criteria and are often referenced by local green codes and utility rebate programs.

  • LEED v4.1 Water Efficiency credits include Outdoor Water Use Reduction, Indoor Water Use Reduction, and Water Metering; indoor reduction is measured against a calculated baseline using fixture flow rates and occupancy.

  • The International Green Construction Code (IgCC) and ASHRAE 189.1 set mandatory and prescriptive green requirements, including water-use reduction percentages and metering of large water uses.

  • CALGreen (California Green Building Standards Code) mandates 20 percent indoor water use reduction over the 2007 baseline for new construction, with additional tiers for voluntary higher performance.

  • Green plumbing code provisions commonly require separate metering for indoor and outdoor water, sub-metering for buildings over a threshold size, and pressure-reducing valves where supply pressure exceeds 80 psi.

  • Commissioning of plumbing systems verifies design flow rates, pressure, water heater performance, and controls; it is a prerequisite or credit in several green rating systems.

  • Backflow prevention and cross-connection control are prerequisites for any recycled or harvested water system; reduced-pressure-zone assemblies protect potable supply from contamination.

Quick reference

Sustainable Plumbing Systems and Materials

  • Rainwater and graywater systems require a cross-connection control assembly and clearly labeled nonpotable piping (often purple for reclaimed water) to prevent contamination of the potable supply.

  • Onsite water reuse system components typically include a storage tank, filtration, disinfection (UV or chlorine), and a pump; treatment level depends on the intended end use, with subsurface irrigation needing less than toilet flushing.

  • Pipe material selection: PEX and CPVC are common for hot and cold distribution; cast iron and PVC are used for drain, waste, and vent; copper remains common where code or local practice requires it.

  • Lead-free requirement: the Safe Drinking Water Act as amended in 2011 limits the weighted average lead content of wetted pipe, fittings, and fixtures to 0.25 percent.

  • Low-flow fixtures reduce hot water demand as well as total water use, which lowers the energy needed to heat water; the water-energy nexus means efficiency in one area supports the other.

  • Gravity-fed and low-pressure systems require careful pipe sizing; excessive velocity causes noise and erosion, and undersized drain lines cause backups, so fixture-unit tables and slope requirements must be followed.

  • Sustainable material selection considers recycled content, local sourcing, durability, and end-of-life recyclability; copper and cast iron have high recycled content and long service lives.

  • Permeable and infiltration-based stormwater practices reduce runoff and recharge groundwater; rain gardens and cisterns are common low-impact development (LID) components in plumbing-adjacent site design.

  • Pressure-reducing valves at the service entrance protect fixtures and piping from excessive pressure and reduce water waste from leaks and fixture wear.

Quick reference

Water Efficiency and Conservation

  • WaterSense maximum flush volume for tank-type toilets is 1.28 gallons per flush (gpf); high-efficiency toilets must not exceed 1.28 gpf, and single-flush HETs commonly run 1.28 gpf while dual-flush units average about 1.1-1.2 gpf.

  • WaterSense showerheads are rated at a maximum 2.0 gallons per minute (gpm) at 80 psi; federal standards allow 2.5 gpm, so a WaterSense-labeled head saves roughly 20 percent versus the federal maximum.

  • WaterSense bathroom faucets and aerators are limited to 1.5 gpm at 60 psi; standard kitchen faucets are 2.2 gpm, and public lavatory faucets are typically 0.5 gpm.

  • Urinal flush volumes: standard 1.0 gpf, high-efficiency 0.5 gpf or less, and WaterSense urinals at 0.5 gpf; waterless urinals use a cartridge or seal liquid instead of flush water.

  • A dual-flush toilet uses a reduced flush (about 0.8-1.1 gallons) for liquid waste and a full flush (about 1.28-1.6 gallons) for solids; the effective average depends on the ratio of reduced to full flushes.

  • Peak demand estimate: fixture units from a plumbing code table are converted to probable flow (gpm) using a demand curve, not by summing fixture flows; Hunter's method underlies most code demand tables.

  • Leak detection rule of thumb: a silent toilet leak can waste 200 gallons or more per day; dye-tablet testing of the tank and a water-meter dial check with all fixtures off are standard diagnostic steps.

  • Rainwater harvesting yield estimate: annual harvest = catchment area (sq ft) x rainfall (in) x 0.623 x runoff coefficient; a 1,000 sq ft roof with 12 in annual rain and 0.85 coefficient yields about 6,350 gallons.

  • Graywater from lavatories, showers, and laundry can supply subsurface irrigation or toilet flushing where the local code allows; kitchen sink, dishwasher, and toilet water are blackwater and excluded.

Quick reference

Energy Efficiency and Renewable Energy

  • Water heater storage setpoint: 120 degrees F is the common efficiency and scald-prevention setpoint; stored water at 140 degrees F or higher requires a tempering valve to limit delivery to about 120 degrees F at fixtures.

  • Heat trap requirement: 24-inch or 6-inch vertical heat traps (or equivalent integral traps) on inlet and outlet of a storage water heater reduce standby loss by limiting convection through the pipes.

  • Tankless (demand) water heaters are rated by maximum temperature rise and flow; a unit's capacity in gpm falls as the required temperature rise increases, so cold inlet temperatures reduce delivered flow.

  • Solar domestic hot water: an SRCC OG-300 certified system rating accounts for collector, storage, and climate; a typical residential system offsets 50-75 percent of annual water heating load depending on location.

  • Solar collector sizing rule of thumb: about 20 sq ft of flat-plate collector per person for a 50-60 percent solar fraction in moderate climates; storage is roughly 1.5-2 gallons per sq ft of collector.

  • Heat pump water heaters (HPWH) typically have a coefficient of performance (COP) of 2-3.5, meaning they move 2-3.5 units of heat per unit of electricity; they cool and dehumidify the space they draw air from.

  • Recirculation systems: a dedicated return line with a pump and aquastat or timer reduces waiting time and wasted water; an on-demand (demand-controlled) system avoids the standby losses of continuous recirculation.

  • Pipe insulation thermal rule: insulate the first 6 feet of hot and cold piping from a storage water heater and all accessible hot piping; insulating cold lines prevents condensation and protects against freezing.

Quick reference

Green Building Codes and Standards

  • The Uniform Plumbing Code (UPC) and International Plumbing Code (IPC) are the two model plumbing codes in the US; green plumbing provisions appear in the Uniform Solar, Hydronics and Geothermal Code and in state green building codes.

  • WaterSense is a voluntary EPA labeling program; labeled products meet efficiency and performance criteria and are often referenced by local green codes and utility rebate programs.

  • LEED v4.1 Water Efficiency credits include Outdoor Water Use Reduction, Indoor Water Use Reduction, and Water Metering; indoor reduction is measured against a calculated baseline using fixture flow rates and occupancy.

  • The International Green Construction Code (IgCC) and ASHRAE 189.1 set mandatory and prescriptive green requirements, including water-use reduction percentages and metering of large water uses.

  • CALGreen (California Green Building Standards Code) mandates 20 percent indoor water use reduction over the 2007 baseline for new construction, with additional tiers for voluntary higher performance.

  • Green plumbing code provisions commonly require separate metering for indoor and outdoor water, sub-metering for buildings over a threshold size, and pressure-reducing valves where supply pressure exceeds 80 psi.

  • Commissioning of plumbing systems verifies design flow rates, pressure, water heater performance, and controls; it is a prerequisite or credit in several green rating systems.

  • Backflow prevention and cross-connection control are prerequisites for any recycled or harvested water system; reduced-pressure-zone assemblies protect potable supply from contamination.

Quick reference

Sustainable Plumbing Systems and Materials

  • Rainwater and graywater systems require a cross-connection control assembly and clearly labeled nonpotable piping (often purple for reclaimed water) to prevent contamination of the potable supply.

  • Onsite water reuse system components typically include a storage tank, filtration, disinfection (UV or chlorine), and a pump; treatment level depends on the intended end use, with subsurface irrigation needing less than toilet flushing.

  • Pipe material selection: PEX and CPVC are common for hot and cold distribution; cast iron and PVC are used for drain, waste, and vent; copper remains common where code or local practice requires it.

  • Lead-free requirement: the Safe Drinking Water Act as amended in 2011 limits the weighted average lead content of wetted pipe, fittings, and fixtures to 0.25 percent.

  • Low-flow fixtures reduce hot water demand as well as total water use, which lowers the energy needed to heat water; the water-energy nexus means efficiency in one area supports the other.

  • Gravity-fed and low-pressure systems require careful pipe sizing; excessive velocity causes noise and erosion, and undersized drain lines cause backups, so fixture-unit tables and slope requirements must be followed.

  • Sustainable material selection considers recycled content, local sourcing, durability, and end-of-life recyclability; copper and cast iron have high recycled content and long service lives.

  • Permeable and infiltration-based stormwater practices reduce runoff and recharge groundwater; rain gardens and cisterns are common low-impact development (LID) components in plumbing-adjacent site design.

  • Pressure-reducing valves at the service entrance protect fixtures and piping from excessive pressure and reduce water waste from leaks and fixture wear.

Quick reference

Water Efficiency and Conservation

  • WaterSense maximum flush volume for tank-type toilets is 1.28 gallons per flush (gpf); high-efficiency toilets must not exceed 1.28 gpf, and single-flush HETs commonly run 1.28 gpf while dual-flush units average about 1.1-1.2 gpf.

  • WaterSense showerheads are rated at a maximum 2.0 gallons per minute (gpm) at 80 psi; federal standards allow 2.5 gpm, so a WaterSense-labeled head saves roughly 20 percent versus the federal maximum.

  • WaterSense bathroom faucets and aerators are limited to 1.5 gpm at 60 psi; standard kitchen faucets are 2.2 gpm, and public lavatory faucets are typically 0.5 gpm.

  • Urinal flush volumes: standard 1.0 gpf, high-efficiency 0.5 gpf or less, and WaterSense urinals at 0.5 gpf; waterless urinals use a cartridge or seal liquid instead of flush water.

  • A dual-flush toilet uses a reduced flush (about 0.8-1.1 gallons) for liquid waste and a full flush (about 1.28-1.6 gallons) for solids; the effective average depends on the ratio of reduced to full flushes.

  • Peak demand estimate: fixture units from a plumbing code table are converted to probable flow (gpm) using a demand curve, not by summing fixture flows; Hunter's method underlies most code demand tables.

  • Leak detection rule of thumb: a silent toilet leak can waste 200 gallons or more per day; dye-tablet testing of the tank and a water-meter dial check with all fixtures off are standard diagnostic steps.

  • Rainwater harvesting yield estimate: annual harvest = catchment area (sq ft) x rainfall (in) x 0.623 x runoff coefficient; a 1,000 sq ft roof with 12 in annual rain and 0.85 coefficient yields about 6,350 gallons.

  • Graywater from lavatories, showers, and laundry can supply subsurface irrigation or toilet flushing where the local code allows; kitchen sink, dishwasher, and toilet water are blackwater and excluded.

Quick reference

Energy Efficiency and Renewable Energy

  • Water heater storage setpoint: 120 degrees F is the common efficiency and scald-prevention setpoint; stored water at 140 degrees F or higher requires a tempering valve to limit delivery to about 120 degrees F at fixtures.

  • Heat trap requirement: 24-inch or 6-inch vertical heat traps (or equivalent integral traps) on inlet and outlet of a storage water heater reduce standby loss by limiting convection through the pipes.

  • Tankless (demand) water heaters are rated by maximum temperature rise and flow; a unit's capacity in gpm falls as the required temperature rise increases, so cold inlet temperatures reduce delivered flow.

  • Solar domestic hot water: an SRCC OG-300 certified system rating accounts for collector, storage, and climate; a typical residential system offsets 50-75 percent of annual water heating load depending on location.

  • Solar collector sizing rule of thumb: about 20 sq ft of flat-plate collector per person for a 50-60 percent solar fraction in moderate climates; storage is roughly 1.5-2 gallons per sq ft of collector.

  • Heat pump water heaters (HPWH) typically have a coefficient of performance (COP) of 2-3.5, meaning they move 2-3.5 units of heat per unit of electricity; they cool and dehumidify the space they draw air from.

  • Recirculation systems: a dedicated return line with a pump and aquastat or timer reduces waiting time and wasted water; an on-demand (demand-controlled) system avoids the standby losses of continuous recirculation.

  • Pipe insulation thermal rule: insulate the first 6 feet of hot and cold piping from a storage water heater and all accessible hot piping; insulating cold lines prevents condensation and protects against freezing.

Quick reference

Green Building Codes and Standards

  • The Uniform Plumbing Code (UPC) and International Plumbing Code (IPC) are the two model plumbing codes in the US; green plumbing provisions appear in the Uniform Solar, Hydronics and Geothermal Code and in state green building codes.

  • WaterSense is a voluntary EPA labeling program; labeled products meet efficiency and performance criteria and are often referenced by local green codes and utility rebate programs.

  • LEED v4.1 Water Efficiency credits include Outdoor Water Use Reduction, Indoor Water Use Reduction, and Water Metering; indoor reduction is measured against a calculated baseline using fixture flow rates and occupancy.

  • The International Green Construction Code (IgCC) and ASHRAE 189.1 set mandatory and prescriptive green requirements, including water-use reduction percentages and metering of large water uses.

  • CALGreen (California Green Building Standards Code) mandates 20 percent indoor water use reduction over the 2007 baseline for new construction, with additional tiers for voluntary higher performance.

  • Green plumbing code provisions commonly require separate metering for indoor and outdoor water, sub-metering for buildings over a threshold size, and pressure-reducing valves where supply pressure exceeds 80 psi.

  • Commissioning of plumbing systems verifies design flow rates, pressure, water heater performance, and controls; it is a prerequisite or credit in several green rating systems.

  • Backflow prevention and cross-connection control are prerequisites for any recycled or harvested water system; reduced-pressure-zone assemblies protect potable supply from contamination.

Quick reference

Sustainable Plumbing Systems and Materials

  • Rainwater and graywater systems require a cross-connection control assembly and clearly labeled nonpotable piping (often purple for reclaimed water) to prevent contamination of the potable supply.

  • Onsite water reuse system components typically include a storage tank, filtration, disinfection (UV or chlorine), and a pump; treatment level depends on the intended end use, with subsurface irrigation needing less than toilet flushing.

  • Pipe material selection: PEX and CPVC are common for hot and cold distribution; cast iron and PVC are used for drain, waste, and vent; copper remains common where code or local practice requires it.

  • Lead-free requirement: the Safe Drinking Water Act as amended in 2011 limits the weighted average lead content of wetted pipe, fittings, and fixtures to 0.25 percent.

  • Low-flow fixtures reduce hot water demand as well as total water use, which lowers the energy needed to heat water; the water-energy nexus means efficiency in one area supports the other.

  • Gravity-fed and low-pressure systems require careful pipe sizing; excessive velocity causes noise and erosion, and undersized drain lines cause backups, so fixture-unit tables and slope requirements must be followed.

  • Sustainable material selection considers recycled content, local sourcing, durability, and end-of-life recyclability; copper and cast iron have high recycled content and long service lives.

  • Permeable and infiltration-based stormwater practices reduce runoff and recharge groundwater; rain gardens and cisterns are common low-impact development (LID) components in plumbing-adjacent site design.

  • Pressure-reducing valves at the service entrance protect fixtures and piping from excessive pressure and reduce water waste from leaks and fixture wear.

Quick reference

Water Efficiency and Conservation

  • WaterSense maximum flush volume for tank-type toilets is 1.28 gallons per flush (gpf); high-efficiency toilets must not exceed 1.28 gpf, and single-flush HETs commonly run 1.28 gpf while dual-flush units average about 1.1-1.2 gpf.

  • WaterSense showerheads are rated at a maximum 2.0 gallons per minute (gpm) at 80 psi; federal standards allow 2.5 gpm, so a WaterSense-labeled head saves roughly 20 percent versus the federal maximum.

  • WaterSense bathroom faucets and aerators are limited to 1.5 gpm at 60 psi; standard kitchen faucets are 2.2 gpm, and public lavatory faucets are typically 0.5 gpm.

  • Urinal flush volumes: standard 1.0 gpf, high-efficiency 0.5 gpf or less, and WaterSense urinals at 0.5 gpf; waterless urinals use a cartridge or seal liquid instead of flush water.

  • A dual-flush toilet uses a reduced flush (about 0.8-1.1 gallons) for liquid waste and a full flush (about 1.28-1.6 gallons) for solids; the effective average depends on the ratio of reduced to full flushes.

  • Peak demand estimate: fixture units from a plumbing code table are converted to probable flow (gpm) using a demand curve, not by summing fixture flows; Hunter's method underlies most code demand tables.

  • Leak detection rule of thumb: a silent toilet leak can waste 200 gallons or more per day; dye-tablet testing of the tank and a water-meter dial check with all fixtures off are standard diagnostic steps.

  • Rainwater harvesting yield estimate: annual harvest = catchment area (sq ft) x rainfall (in) x 0.623 x runoff coefficient; a 1,000 sq ft roof with 12 in annual rain and 0.85 coefficient yields about 6,350 gallons.

  • Graywater from lavatories, showers, and laundry can supply subsurface irrigation or toilet flushing where the local code allows; kitchen sink, dishwasher, and toilet water are blackwater and excluded.

Quick reference

Energy Efficiency and Renewable Energy

  • Water heater storage setpoint: 120 degrees F is the common efficiency and scald-prevention setpoint; stored water at 140 degrees F or higher requires a tempering valve to limit delivery to about 120 degrees F at fixtures.

  • Heat trap requirement: 24-inch or 6-inch vertical heat traps (or equivalent integral traps) on inlet and outlet of a storage water heater reduce standby loss by limiting convection through the pipes.

  • Tankless (demand) water heaters are rated by maximum temperature rise and flow; a unit's capacity in gpm falls as the required temperature rise increases, so cold inlet temperatures reduce delivered flow.

  • Solar domestic hot water: an SRCC OG-300 certified system rating accounts for collector, storage, and climate; a typical residential system offsets 50-75 percent of annual water heating load depending on location.

  • Solar collector sizing rule of thumb: about 20 sq ft of flat-plate collector per person for a 50-60 percent solar fraction in moderate climates; storage is roughly 1.5-2 gallons per sq ft of collector.

  • Heat pump water heaters (HPWH) typically have a coefficient of performance (COP) of 2-3.5, meaning they move 2-3.5 units of heat per unit of electricity; they cool and dehumidify the space they draw air from.

  • Recirculation systems: a dedicated return line with a pump and aquastat or timer reduces waiting time and wasted water; an on-demand (demand-controlled) system avoids the standby losses of continuous recirculation.

  • Pipe insulation thermal rule: insulate the first 6 feet of hot and cold piping from a storage water heater and all accessible hot piping; insulating cold lines prevents condensation and protects against freezing.

Quick reference

Green Building Codes and Standards

  • The Uniform Plumbing Code (UPC) and International Plumbing Code (IPC) are the two model plumbing codes in the US; green plumbing provisions appear in the Uniform Solar, Hydronics and Geothermal Code and in state green building codes.

  • WaterSense is a voluntary EPA labeling program; labeled products meet efficiency and performance criteria and are often referenced by local green codes and utility rebate programs.

  • LEED v4.1 Water Efficiency credits include Outdoor Water Use Reduction, Indoor Water Use Reduction, and Water Metering; indoor reduction is measured against a calculated baseline using fixture flow rates and occupancy.

  • The International Green Construction Code (IgCC) and ASHRAE 189.1 set mandatory and prescriptive green requirements, including water-use reduction percentages and metering of large water uses.

  • CALGreen (California Green Building Standards Code) mandates 20 percent indoor water use reduction over the 2007 baseline for new construction, with additional tiers for voluntary higher performance.

  • Green plumbing code provisions commonly require separate metering for indoor and outdoor water, sub-metering for buildings over a threshold size, and pressure-reducing valves where supply pressure exceeds 80 psi.

  • Commissioning of plumbing systems verifies design flow rates, pressure, water heater performance, and controls; it is a prerequisite or credit in several green rating systems.

  • Backflow prevention and cross-connection control are prerequisites for any recycled or harvested water system; reduced-pressure-zone assemblies protect potable supply from contamination.

Quick reference

Sustainable Plumbing Systems and Materials

  • Rainwater and graywater systems require a cross-connection control assembly and clearly labeled nonpotable piping (often purple for reclaimed water) to prevent contamination of the potable supply.

  • Onsite water reuse system components typically include a storage tank, filtration, disinfection (UV or chlorine), and a pump; treatment level depends on the intended end use, with subsurface irrigation needing less than toilet flushing.

  • Pipe material selection: PEX and CPVC are common for hot and cold distribution; cast iron and PVC are used for drain, waste, and vent; copper remains common where code or local practice requires it.

  • Lead-free requirement: the Safe Drinking Water Act as amended in 2011 limits the weighted average lead content of wetted pipe, fittings, and fixtures to 0.25 percent.

  • Low-flow fixtures reduce hot water demand as well as total water use, which lowers the energy needed to heat water; the water-energy nexus means efficiency in one area supports the other.

  • Gravity-fed and low-pressure systems require careful pipe sizing; excessive velocity causes noise and erosion, and undersized drain lines cause backups, so fixture-unit tables and slope requirements must be followed.

  • Sustainable material selection considers recycled content, local sourcing, durability, and end-of-life recyclability; copper and cast iron have high recycled content and long service lives.

  • Permeable and infiltration-based stormwater practices reduce runoff and recharge groundwater; rain gardens and cisterns are common low-impact development (LID) components in plumbing-adjacent site design.

  • Pressure-reducing valves at the service entrance protect fixtures and piping from excessive pressure and reduce water waste from leaks and fixture wear.

Quick reference

Water Efficiency and Conservation

  • WaterSense maximum flush volume for tank-type toilets is 1.28 gallons per flush (gpf); high-efficiency toilets must not exceed 1.28 gpf, and single-flush HETs commonly run 1.28 gpf while dual-flush units average about 1.1-1.2 gpf.

  • WaterSense showerheads are rated at a maximum 2.0 gallons per minute (gpm) at 80 psi; federal standards allow 2.5 gpm, so a WaterSense-labeled head saves roughly 20 percent versus the federal maximum.

  • WaterSense bathroom faucets and aerators are limited to 1.5 gpm at 60 psi; standard kitchen faucets are 2.2 gpm, and public lavatory faucets are typically 0.5 gpm.

  • Urinal flush volumes: standard 1.0 gpf, high-efficiency 0.5 gpf or less, and WaterSense urinals at 0.5 gpf; waterless urinals use a cartridge or seal liquid instead of flush water.

  • A dual-flush toilet uses a reduced flush (about 0.8-1.1 gallons) for liquid waste and a full flush (about 1.28-1.6 gallons) for solids; the effective average depends on the ratio of reduced to full flushes.

  • Peak demand estimate: fixture units from a plumbing code table are converted to probable flow (gpm) using a demand curve, not by summing fixture flows; Hunter's method underlies most code demand tables.

  • Leak detection rule of thumb: a silent toilet leak can waste 200 gallons or more per day; dye-tablet testing of the tank and a water-meter dial check with all fixtures off are standard diagnostic steps.

  • Rainwater harvesting yield estimate: annual harvest = catchment area (sq ft) x rainfall (in) x 0.623 x runoff coefficient; a 1,000 sq ft roof with 12 in annual rain and 0.85 coefficient yields about 6,350 gallons.

  • Graywater from lavatories, showers, and laundry can supply subsurface irrigation or toilet flushing where the local code allows; kitchen sink, dishwasher, and toilet water are blackwater and excluded.

Quick reference

Energy Efficiency and Renewable Energy

  • Water heater storage setpoint: 120 degrees F is the common efficiency and scald-prevention setpoint; stored water at 140 degrees F or higher requires a tempering valve to limit delivery to about 120 degrees F at fixtures.

  • Heat trap requirement: 24-inch or 6-inch vertical heat traps (or equivalent integral traps) on inlet and outlet of a storage water heater reduce standby loss by limiting convection through the pipes.

  • Tankless (demand) water heaters are rated by maximum temperature rise and flow; a unit's capacity in gpm falls as the required temperature rise increases, so cold inlet temperatures reduce delivered flow.

  • Solar domestic hot water: an SRCC OG-300 certified system rating accounts for collector, storage, and climate; a typical residential system offsets 50-75 percent of annual water heating load depending on location.

  • Solar collector sizing rule of thumb: about 20 sq ft of flat-plate collector per person for a 50-60 percent solar fraction in moderate climates; storage is roughly 1.5-2 gallons per sq ft of collector.

  • Heat pump water heaters (HPWH) typically have a coefficient of performance (COP) of 2-3.5, meaning they move 2-3.5 units of heat per unit of electricity; they cool and dehumidify the space they draw air from.

  • Recirculation systems: a dedicated return line with a pump and aquastat or timer reduces waiting time and wasted water; an on-demand (demand-controlled) system avoids the standby losses of continuous recirculation.

  • Pipe insulation thermal rule: insulate the first 6 feet of hot and cold piping from a storage water heater and all accessible hot piping; insulating cold lines prevents condensation and protects against freezing.

Quick reference

Green Building Codes and Standards

  • The Uniform Plumbing Code (UPC) and International Plumbing Code (IPC) are the two model plumbing codes in the US; green plumbing provisions appear in the Uniform Solar, Hydronics and Geothermal Code and in state green building codes.

  • WaterSense is a voluntary EPA labeling program; labeled products meet efficiency and performance criteria and are often referenced by local green codes and utility rebate programs.

  • LEED v4.1 Water Efficiency credits include Outdoor Water Use Reduction, Indoor Water Use Reduction, and Water Metering; indoor reduction is measured against a calculated baseline using fixture flow rates and occupancy.

  • The International Green Construction Code (IgCC) and ASHRAE 189.1 set mandatory and prescriptive green requirements, including water-use reduction percentages and metering of large water uses.

  • CALGreen (California Green Building Standards Code) mandates 20 percent indoor water use reduction over the 2007 baseline for new construction, with additional tiers for voluntary higher performance.

  • Green plumbing code provisions commonly require separate metering for indoor and outdoor water, sub-metering for buildings over a threshold size, and pressure-reducing valves where supply pressure exceeds 80 psi.

  • Commissioning of plumbing systems verifies design flow rates, pressure, water heater performance, and controls; it is a prerequisite or credit in several green rating systems.

  • Backflow prevention and cross-connection control are prerequisites for any recycled or harvested water system; reduced-pressure-zone assemblies protect potable supply from contamination.

Quick reference

Sustainable Plumbing Systems and Materials

  • Rainwater and graywater systems require a cross-connection control assembly and clearly labeled nonpotable piping (often purple for reclaimed water) to prevent contamination of the potable supply.

  • Onsite water reuse system components typically include a storage tank, filtration, disinfection (UV or chlorine), and a pump; treatment level depends on the intended end use, with subsurface irrigation needing less than toilet flushing.

  • Pipe material selection: PEX and CPVC are common for hot and cold distribution; cast iron and PVC are used for drain, waste, and vent; copper remains common where code or local practice requires it.

  • Lead-free requirement: the Safe Drinking Water Act as amended in 2011 limits the weighted average lead content of wetted pipe, fittings, and fixtures to 0.25 percent.

  • Low-flow fixtures reduce hot water demand as well as total water use, which lowers the energy needed to heat water; the water-energy nexus means efficiency in one area supports the other.

  • Gravity-fed and low-pressure systems require careful pipe sizing; excessive velocity causes noise and erosion, and undersized drain lines cause backups, so fixture-unit tables and slope requirements must be followed.

  • Sustainable material selection considers recycled content, local sourcing, durability, and end-of-life recyclability; copper and cast iron have high recycled content and long service lives.

  • Permeable and infiltration-based stormwater practices reduce runoff and recharge groundwater; rain gardens and cisterns are common low-impact development (LID) components in plumbing-adjacent site design.

  • Pressure-reducing valves at the service entrance protect fixtures and piping from excessive pressure and reduce water waste from leaks and fixture wear.