IAPMO Green Plumber study materials
IAPMO Green Plumber study resources

IAPMO Green Plumber key terms

IAPMO Green Plumber · Get comfortable with the vocabulary.

WaterSense labeled fixture

A plumbing product independently certified to meet the U.S. EPA's water-saving and performance criteria, such as a toilet using 1.28 gallons or less per flush. The label helps buyers compare fixtures by verified efficiency rather than marketing claims.

Related: Gallons per flush (gpf), Maximum performance (MaP) score, Uniform North American Requirements (UNAR)
Gallons per flush (gpf)

The volume of water a toilet or urinal consumes in a single flush cycle, measured in U.S. gallons. It is the primary metric used to compare flush fixture efficiency and to verify compliance with plumbing code maximums.

Related: WaterSense labeled fixture, Dual-flush toilet, Flow rate (gpm)
Flow rate (gpm)

The volume of water passing a point per minute, usually expressed in gallons per minute for faucets, showerheads, and appliances. Codes and efficiency programs set maximum rates to limit consumption without sacrificing user performance.

Related: Gallons per flush (gpf), Aerator, Pressure-compensating aerator
Aerator

A small screw-on fitting at a faucet outlet that mixes air into the water stream, reducing flow while maintaining a wet, usable stream. Aerators are a low-cost retrofit that cuts lavatory water use noticeably.

Related: Flow rate (gpm), Pressure-compensating aerator, Low-flow showerhead
Pressure-compensating aerator

A faucet insert that holds a nearly constant flow rate across a wide range of supply pressures, so a fixture does not waste water when pressure is high. It helps ensure rated flow limits are actually achieved in the field.

Related: Aerator, Flow rate (gpm), Pressure-reducing valve
Dual-flush toilet

A toilet offering two flush volumes, typically a smaller flush for liquid waste and a larger one for solids. It reduces average water use per use compared with a single-flush fixture while meeting performance standards.

Related: Gallons per flush (gpf), Maximum performance (MaP) score, WaterSense labeled fixture
Maximum performance (MaP) score

A test result reporting the mass of solid waste a toilet can reliably clear in a single flush, expressed in grams. Higher scores indicate stronger drainline carry and help specifiers pair low flush volumes with dependable performance.

Related: Gallons per flush (gpf), Dual-flush toilet, Drainline carry
Drainline carry

The ability of a reduced flush volume to transport waste through a building drain and sewer over distance. Low-flow fixtures can fail to move solids if pipe slope or sizing is poor, so carry is evaluated during design.

Related: Maximum performance (MaP) score, Graywater, Sewer connection
Low-flow showerhead

A shower fixture designed to deliver a reduced flow rate, commonly 2.0 gallons per minute or less under current standards. Efficient models use spray pattern and orifice design rather than volume to maintain a satisfying shower.

Related: Flow rate (gpm), Aerator, Water heating energy factor
Graywater

Wastewater from bathtubs, showers, lavatories, and laundry that has not been contaminated by toilet discharge or kitchen waste. It can be treated and reused for subsurface irrigation or flushing where local rules allow.

Related: Blackwater, Rainwater harvesting, Drainline carry
Blackwater

Wastewater containing toilet discharge or significant organic and pathogen loading, including kitchen sink waste in many jurisdictions. It requires full treatment before reuse and is regulated more strictly than graywater.

Related: Graywater, Rainwater harvesting, Onsite wastewater treatment system
Rainwater harvesting

The collection and storage of roof runoff for nonpotable uses such as irrigation, cooling tower makeup, or toilet flushing. Systems typically include first-flush diversion, filtration, and backflow protection to safeguard the potable supply.

Related: Graywater, Backflow preventer, Cistern
Cistern

A tank, above or below ground, that stores harvested rainwater or treated graywater for later use. Sizing depends on catchment area, rainfall patterns, and demand, and the tank must be protected from contamination and mosquito breeding.

Related: Rainwater harvesting, Graywater, Backflow preventer
Water meter

A device that measures the volume of water delivered to a building or submetered zone. Metering enables leak detection, consumption benchmarking, and billing that rewards conservation, and is often required for green certification.

Related: Submeter, Water audit, Leak detection
Submeter

A secondary meter installed downstream of the main meter to track water use by a specific tenant, building system, or end use. Submetering supports accountability and helps operators identify abnormal consumption quickly.

Related: Water meter, Water audit, Leak detection
Water audit

A structured accounting of all water entering and leaving a facility, used to find losses, leaks, and inefficient end uses. Results guide retrofit priorities and establish a baseline for measuring conservation savings.

Related: Water meter, Leak detection, Submeter
Leak detection

The process of finding unintended water loss in piping, fixtures, and equipment using metering, acoustic listening, pressure testing, or flow monitoring. Early detection protects water efficiency gains and prevents property damage.

Related: Water audit, Water meter, Pressure-reducing valve
Pressure-reducing valve

A device that lowers incoming supply pressure to a safe, stable level for downstream fixtures and piping. Correct pressure control reduces waste from high-flow leakage and protects fittings from premature failure.

Related: Pressure-compensating aerator, Leak detection, Thermal expansion tank
Water heating energy factor

A measure of a water heater's overall efficiency, relating delivered hot water energy to total energy consumed, including standby losses. Higher values indicate a more efficient unit, though ratings vary by test method and product class.

Related: Uniform energy factor (UEF), Heat pump water heater, Solar thermal water heating
Uniform energy factor (UEF)

The current federal efficiency metric for residential water heaters, replacing the energy factor and based on a standardized daily draw profile. It allows comparison across storage, instantaneous, and heat pump types under one framework.

Related: Water heating energy factor, Heat pump water heater, Recirculating hot water system
Heat pump water heater

A water heater that moves heat from surrounding air into stored water using a vapor-compression cycle rather than direct electric resistance. It can cut water heating energy substantially but needs adequate space and affects space conditioning.

Related: Uniform energy factor (UEF), Solar thermal water heating, Condensate management
Solar thermal water heating

A system that uses solar collectors to heat water or a transfer fluid, often backed up by a conventional heater. Design must address freeze protection, stagnation, and proper orientation to deliver expected savings.

Related: Heat pump water heater, Recirculating hot water system, Uniform energy factor (UEF)
Recirculating hot water system

A pump-and-return arrangement that keeps hot water circulating near fixtures to reduce the wait for hot water. It saves water wasted during warm-up but consumes pump and reheating energy, so controls and insulation matter.

Related: Structured plumbing, Insulation of hot water piping, Demand-initiated recirculation
Demand-initiated recirculation

A hot water control strategy that starts the circulation pump only when a user requests hot water, rather than running continuously. It captures most of the water savings of recirculation while limiting standby energy loss.

Related: Recirculating hot water system, Structured plumbing, Insulation of hot water piping
Insulation of hot water piping

Thermal wrapping applied to hot water lines to reduce heat loss between the heater and fixtures. Well-insulated runs shorten warm-up time, saving both water and the energy used to reheat cooled water in the pipe.

Related: Recirculating hot water system, Demand-initiated recirculation, Structured plumbing
Structured plumbing

A manifold-and-home-run piping layout that places small-diameter lines to each fixture from a central distribution point. It reduces the volume of water sitting in pipes, shortening hot water wait times and limiting wasted draw.

Related: Recirculating hot water system, Demand-initiated recirculation, PEX piping
Condensate management

The collection and safe disposal of water produced by condensing appliances such as high-efficiency furnaces, heat pump water heaters, and air conditioners. Neutralization or proper drainage protects piping and drains from corrosion.

Related: Heat pump water heater, Condensing boiler, Trap primer
Condensing boiler

A boiler designed to recover latent heat from flue gas by condensing water vapor, achieving higher efficiency than non-condensing models. It produces acidic condensate that must be neutralized or piped to a suitable drain.

Related: Condensate management, Combustion air, Uniform energy factor (UEF)
Combustion air

The air supplied to fuel-burning appliances for safe, complete combustion. Green building practice requires adequate, often sealed, combustion air to protect indoor air quality and prevent backdrafting of flue gases.

Related: Condensing boiler, Backdrafting, Makeup air
Backdrafting

The reverse flow of combustion products down a vent into occupied space, often caused by depressurization or blocked flues. It is a serious health hazard that efficient envelope design and proper venting must guard against.

Related: Combustion air, Makeup air, Trap primer
Makeup air

Outdoor air supplied to replace air exhausted by fans, dryers, or vent hoods so building pressure stays balanced. Adequate makeup air prevents backdrafting and helps exhaust systems perform as designed.

Related: Combustion air, Backdrafting, Ventilation rate
Backflow preventer

A device that stops reverse flow of contaminated water into the potable supply, using air gaps, check valves, or reduced-pressure zones. It is required for irrigation, boilers, and any cross-connection risk.

Related: Cross-connection, Air gap, Rainwater harvesting
Cross-connection

Any actual or potential link between the potable water system and a source of contamination. Eliminating or protecting cross-connections is a core public health requirement in plumbing codes and green reuse systems.

Related: Backflow preventer, Air gap, Graywater
Air gap

An unobstructed vertical separation between a water supply outlet and the flood level of a receiving fixture. It provides the highest level of backflow protection because no mechanical parts can fail.

Related: Backflow preventer, Cross-connection, Indirect waste receptor
Indirect waste receptor

A fixture or fitting that receives discharged waste through an air gap rather than a direct pipe connection. It protects the potable supply and drainage system from contamination while allowing needed drainage.

Related: Air gap, Condensate management, Trap primer
Trap primer

A device that automatically adds a small amount of water to a floor drain trap to maintain the seal. Green buildings with efficient fixtures and low traffic can let traps evaporate, allowing sewer gas into occupied space.

Related: Indirect waste receptor, Condensate management, Makeup air
Uniform North American Requirements (UNAR)

A harmonized set of minimum water efficiency and performance requirements for plumbing fixtures, developed to align programs across North America. It gives manufacturers and specifiers one consistent benchmark.

Related: WaterSense labeled fixture, Gallons per flush (gpf), Leadership in Energy and Environmental Design (LEED)
Leadership in Energy and Environmental Design (LEED)

A voluntary green building rating system that awards points across categories including water efficiency, energy, materials, and indoor environmental quality. Plumbing choices such as efficient fixtures and metering contribute to credits.

Related: Uniform North American Requirements (UNAR), Water audit, Volatile organic compound (VOC) limit
Volatile organic compound (VOC) limit

A cap on the amount of volatile organic compounds emitted by products such as pipe cement, primers, and sealants. Low-VOC products protect indoor air quality and installer health and are favored by green rating systems.

Related: Leadership in Energy and Environmental Design (LEED), PEX piping, Lead-free solder
Lead-free solder

Solder used for potable water piping that meets current low-lead content limits, typically lead-free alloys. Its use prevents lead leaching into drinking water and is required by plumbing codes for potable systems.

Related: Volatile organic compound (VOC) limit, Cross-connection, PEX piping
PEX piping

Flexible crosslinked polyethylene tubing widely used for potable water distribution. It resists corrosion and scale, allows fewer fittings, and supports home-run layouts, though it must be protected from sunlight and freezing.

Related: Structured plumbing, Lead-free solder, Volatile organic compound (VOC) limit
Onsite wastewater treatment system

A system that treats sewage at or near the point of generation, such as a septic system or advanced treatment unit, before dispersal or reuse. Proper siting, sizing, and maintenance protect groundwater and public health.

Related: Blackwater, Graywater, Waterless urinal
Waterless urinal

A urinal that uses a liquid seal or cartridge instead of flushing water to control odors and carry waste to the drain. It eliminates flush water entirely but requires correct cartridge maintenance and drainline design.

Related: Onsite wastewater treatment system, Drainline carry, Gallons per flush (gpf)