- Mechanical permit requirement
- A permit is required before installing, altering, or replacing regulated mechanical equipment. The permit must be obtained from the authority having jurisdiction and work must follow approved plans.
- Concealment inspection
- Mechanical work cannot be covered or concealed until it has been inspected and approved. The contractor requests inspection before drywall, insulation, or other coverings are installed over the work.
- Certificate of occupancy
- Issued after final inspection confirms the mechanical installation complies with the approved plans and code. It authorizes occupancy or use of the completed building or space.
- Stop-work order
- An enforcement action by the AHJ halting work that is unsafe or noncompliant. Work may not resume until the cited condition is corrected and the order is lifted.
- Board of appeals
- The body established by local ordinance to hear appeals of AHJ decisions and interpretations. Appeals must be filed within the time and manner the jurisdiction specifies.
- Approved plans on site
- Approved drawings and the permit must be kept available at the job site for the inspector. Deviations from approved plans require a revised permit before proceeding.
- AHJ authority
- The authority having jurisdiction enforces the mechanical code, reviews plans, conducts inspections, and may revoke permits or order corrections for code violations.
- Combustion air requirement
- Appliances must receive adequate air for combustion, dilution, and ventilation. The code permits prescriptive opening methods or engineered designs that demonstrate sufficient air supply.
- Plenum installation listing
- Equipment and materials installed in air plenums must be listed for that use and meet limits on combustibility and smoke developed, reducing fire and smoke spread risk.
- Garage equipment protection
- Mechanical equipment in garages must be protected from vehicle damage and, where required, elevated so ignition sources sit above the floor to reduce vapor ignition.
- Appliance access opening
- Appliances in attics, crawl spaces, or closets need a service access opening sized to the equipment. Access must not pass through another tenant's space.
- Refrigerant safety group
- Refrigerants are classified by toxicity and flammability, such as A1, A2L, A3, and B1. Higher-risk groups face stricter charge limits, ventilation, and occupancy restrictions.
- Condensate drain trap
- Condensate drains require a trap where specified, must slope to a disposal point, and must be protected from freezing. Secondary drain or pan protection prevents overflow damage.
- Duct pressure class
- Ducts are classified by static pressure and velocity into pressure classes. Construction, sealing, and leakage class must match the class required for the system.
- Equipment sizing load calculation
- Sensible and latent loads are calculated by an accepted method to size equipment. Oversizing causes short cycling, poor dehumidification, and comfort problems.
- External static pressure limit
- Total external static pressure equals duct friction loss plus component pressure drops. It must not exceed the air handler's rated capability or airflow will fall short of design.
- Refrigerant line sizing
- Line size depends on capacity, equivalent length, and oil return. Suction lines must keep velocity high enough for oil return while liquid lines limit pressure drop.
- Category IV venting
- Condensing appliances are Category IV and require listed plastic venting installed with slope back to the appliance so condensate drains properly and does not pool.
- Gas piping sizing methods
- Gas piping is sized using the longest length or branch length method with the code tables, accounting for gas specific gravity and allowable pressure drop.
- Flexible duct installation
- Flexible duct runs should be short and straight. Compression and sharp bends reduce delivered airflow and effective capacity and should be avoided.
- Outdoor unit clearance
- Outdoor units need clearances for airflow and service per the listing. Recirculating discharge air reduces capacity and can trip high-pressure controls.
- Return air restrictions
- Return air cannot be drawn from bathrooms, kitchens, or garages. These spaces require dedicated exhaust, and return paths must have adequate free area.
- Refrigerant pressure test
- Refrigerant piping is pressure tested with dry nitrogen or as the code allows before evacuation. The system is then evacuated to a specified micron level and held.
- Gas piping test
- Gas piping is tested with air or inert gas at the code-specified pressure for the required duration. The test medium and gauge must be visible to the inspector.
- Duct leakage testing
- Where the code requires it, duct leakage is measured and must not exceed the leakage class for the duct's pressure class and seal level.
- Combustion analysis
- Combustion testing measures steady-state efficiency, flue and ambient carbon monoxide, and draft. Elevated CO indicates incomplete combustion or a venting problem.
- Superheat and subcooling
- High superheat with low subcooling suggests undercharge. High subcooling with high head pressure suggests overcharge or restricted airflow. These measurements verify charge.
- Airflow verification
- Airflow is measured with a duct traverse or flow hood and compared to design. Dampers or fan speed are adjusted to balance supply and return.
- Plan review focus
- Reviewers check equipment listings, clearances, combustion air, venting, duct class, and refrigerant safety group against code provisions before issuing a permit.
- Notice of violation
- A written enforcement notice identifies the code section, the specific defect, the required correction, and a reinspection date for the noncompliant installation.
- Unsafe condition order
- Blocked combustion air, disconnected vents, or refrigerant leaks into occupied space may be ordered corrected immediately, with equipment shut off until repaired.
- Inspection documentation
- Inspectors record findings with photographs, measurements, and test results. This record supports enforcement actions, reinspections, and any subsequent appeal.