ICC B3 · Keep the key ideas within reach.

Quick reference

Administration

  • A building permit is required for erection, construction, enlargement, alteration, repair, move, demolition, or change of occupancy; ordinary repairs are exempt.

  • A permit is abandoned if work does not commence within 180 days of issuance or is suspended for 180 days; the building official may then revoke it.

  • Construction documents must be approved before a permit is issued, and an approved set must be kept on the site while work is in progress.

  • A certificate of occupancy is issued after final inspection confirms compliance and is required before a building may be occupied; a change of occupancy requires a new certificate.

  • The board of appeals hears appeals of building official interpretations and code variances; filing an appeal does not stay enforcement unless the board orders a stay.

  • Stop work orders must be in writing and remain in effect until the cited conditions are corrected and the order is rescinded.

  • The building official may order repair, vacation, or demolition of a structure found to be unsafe or dangerous to life or health.

  • Permit fees are established by the jurisdiction and are typically based on the valuation of the work as determined by the building official.

Quick reference

Scope and General Provisions

  • Occupancy groups are A (assembly), B (business), E (educational), F (factory), H (high hazard), I (institutional), M (mercantile), R (residential), S (storage), and U (utility).

  • H occupancies subdivide H-1 through H-5, I occupancies I-1 through I-4, and A occupancies A-1 through A-5 according to hazard or use.

  • An accessory occupancy must be ancillary to the main occupancy and may not exceed 10 percent of the floor area of the story on which it is located.

  • Incidental uses listed in Table 509 must be separated from the remainder of the building but are not classified as separate occupancies.

  • Building height is the vertical distance from grade plane to the average height of the highest roof surface.

  • Grade plane is a reference plane representing the average finished ground level adjoining the building at exterior walls.

  • A story above grade plane is one whose floor is more than 6 feet above grade plane or more than 6 feet above the lowest adjacent exterior grade.

  • A mezzanine is an intermediate level with a floor area not exceeding one-third of the floor area of the room or space it occupies.

Quick reference

Building Planning and Construction Types

  • Construction Types I through V are each split into A (protected) and B (unprotected); Type IA is the most restrictive and Type VB the least.

  • Table 601 fire-resistance ratings: Type IA structural frame 3 hours, IB 2 hours, IIA 1 hour, IIB 0 hours, IV heavy timber, VA 1 hour, VB 0 hours.

  • Allowable building area: Aa = At + (At x If) + (At x Is), where At is the tabular area from Table 506.2.

  • Frontage increase: If = (F/P - 0.25) x W/30, where F is the perimeter on open frontage, P is total perimeter, and W is the open width (maximum 30 feet); If may not exceed 0.75.

  • Sprinkler increase: Is = 2.0 (200 percent) for a fully sprinklered one-story building and 3.0 (300 percent) for a fully sprinklered multistory building.

  • Fire walls divide a building into separate buildings, must be continuous from the foundation to at least 30 inches above the roof, and are rated 2 to 4 hours.

  • Occupancy separations are determined from Table 508.4; mixed occupancies are regulated by Section 508.

  • Exterior wall fire-resistance ratings and opening limits depend on the fire separation distance per Table 602 and Table 705.8.

  • Unlimited area buildings are permitted only under the specific conditions of Section 507, which generally require sprinklers and open frontage.

Quick reference

Fire and Smoke Protection Features

  • Fire-resistance ratings of assemblies are established by testing to ASTM E119 or UL 263, or by approved prescriptive methods in Chapter 7.

  • Opening protective ratings are selected from Table 716.5; fire door assemblies must comply with NFPA 80 and fire windows with NFPA 80.

  • Shaft enclosures are required for stairways, elevators, chutes, and ducts under Section 713, with rated construction and opening protectives at each floor.

  • Fireblocking is required in concealed combustible spaces to inhibit flame spread; draftstopping must subdivide combustible attics and crawl spaces into areas not exceeding 3,000 square feet.

  • Through-penetration firestop systems are tested to ASTM E814 or UL 1479; fire-resistive joint systems are tested to ASTM E1966 or UL 2079.

  • Smoke barriers must have at least a 1-hour fire-resistance rating and be continuous from the floor to the underside of the floor or roof deck above.

  • Smoke partitions have no fire-resistance rating requirement but must resist smoke movement and extend from the floor to the ceiling above.

  • Exterior wall openings must be limited by fire separation distance, and protected where required, in accordance with Table 705.8.

Quick reference

Means of Egress and Accessibility

  • Occupant load equals floor area divided by the occupant load factor in Table 1004.5; business use is 150 gross square feet per occupant.

  • Egress width is 0.2 inch per occupant for level components and 0.3 inch per occupant for stairs in unsprinklered buildings; 0.15 and 0.2 inch respectively where sprinklered.

  • The number of required exits is set by Table 1006.2.1 based on occupant load and number of stories, with two exits commonly required at 50 or more occupants.

  • Dead-end corridors are limited to 20 feet in unsprinklered buildings and 50 feet in sprinklered buildings for Groups B, E, F, M, R-1, S, and U.

  • Exit signs are required where the path of egress travel is not readily apparent, and means of egress must be illuminated to at least 1 footcandle average and 0.1 footcandle minimum at the floor.

  • The accessible route must be at least 36 inches clear; clear floor space for a wheelchair is 30 by 48 inches and turning space is a 60-inch circle or T-shape.

  • Doors in an accessible route must provide at least 32 inches clear width and the required maneuvering clearance on each side.

  • Ramps have a maximum slope of 1:12, a maximum rise of 30 inches between landings, and landings at least 60 inches long.

  • Accessible parking requires a 96-inch-wide space with a 60-inch access aisle; van-accessible spaces require a 96-inch aisle or a 132-inch-wide space.

Quick reference

Structural

  • Design live loads come from Table 1607.1: office 50 psf, residential 40 psf, public corridors 100 psf, light storage 125 psf.

  • Dead load consists of the weight of all materials, equipment, and fixed partitions supported by the structure.

  • Basic strength (LRFD) load combination: 1.2D + 1.6L + 0.5(Lr or S or R).

  • Wind design uses ultimate design wind speeds from the code maps, adjusted for exposure category, risk category, and height above grade.

  • Seismic design category is assigned from mapped spectral accelerations Ss and S1, the site class, and the risk category, and ranges from A through F.

  • Deflection limits: floor members L/360 under live load where supporting plaster or stucco ceilings and L/240 otherwise; roof members L/180 under live load.

  • Structural materials are governed by ACI 318 for concrete, AISC 360 for steel, NDS for wood, and TMS 402 for masonry.

  • Special inspections under Chapter 17 cover items such as welding, high-strength bolting, concrete placement, and soils, performed by an approved agency.

Quick reference

Envelope

  • Fire separation distance is measured from the exterior wall face to the lot line, the centerline of a street or alley, or the nearest wall of another building on the same lot.

  • Exterior walls must be rated and protected in accordance with Table 602 based on occupancy group and fire separation distance.

  • A weather-resistant barrier must be installed behind exterior wall cladding, with flashing at openings, penetrations, and wall bases.

  • Combustible exterior wall coverings are limited by height, fire separation distance, and sprinkler protection in accordance with Chapter 14 tables.

  • Roof coverings are classified A, B, or C by ASTM E108 testing; the required class depends on occupancy and fire separation distance.

  • The exterior wall envelope must be designed to prevent water accumulation within the assembly, using drainage planes, weep holes, and vapor retarders as appropriate.

  • Glazing in hazardous locations, including glazing adjacent to walking surfaces and in doors, must be safety glazing per Section 2406.

Quick reference

Energy and Life-Safety Systems

  • Automatic sprinkler systems are required by occupancy, area, and height; NFPA 13 applies to most buildings, NFPA 13R to residential occupancies up to four stories, and NFPA 13D to one- and two-family dwellings.

  • Fire alarm and detection systems are required by Chapter 9 and include manual pull stations, occupant notification appliances, and automatic detection where specified.

  • Standpipes are Class I (2.5-inch fire department outlets), Class II (1.5-inch occupant hose), or Class III (both), installed per Section 905.

  • Smoke control uses pressurization, exhaust, or passive separation to maintain tenable conditions along egress paths during a fire.

  • Portable fire extinguishers must be provided in accordance with IFC Section 906, with spacing and classification based on the hazard.

  • A high-rise building has an occupied floor more than 75 feet above the lowest level of fire department vehicle access and triggers additional features such as a fire command center.

  • Chapter 13 adopts the International Energy Conservation Code, regulating envelope, mechanical, lighting, and power requirements by climate zone 1 through 8.

  • Fire department access roads and fire department connections must be provided and maintained for the building's fire protection systems.