  • A plumbing permit is required before installing, altering, repairing, or replacing a plumbing system, except for minor work specifically exempted by the code.

  • Typical permit exemptions include clearing stoppages, replacing a faucet washer, and other minor repairs that do not change the piping arrangement.

  • Plans and specifications must be submitted for review when required by the code official, and installed work must match the approved plans.

  • Required inspections commonly include rough-in of water supply and drain-waste-vent piping, water heater installation, building sewer, and final inspection.

  • Drain-waste-vent piping must be tested before concealment; the code specifies water or air test methods, pressures, and durations.

  • A stop-work order may be issued for work that is unsafe, contrary to code, or performed without a permit, and work must stop until the order is rescinded.

  • The code official may approve alternative materials or methods when they are equivalent in quality, strength, effectiveness, fire resistance, durability, and safety.

  • A certificate of occupancy is not issued until the final plumbing inspection has been approved.

Quick reference

General Provisions and Definitions

  • "Approved" means acceptable to the code official because the material, method, or product conforms to the code or an approved standard.

  • "Plumbing" includes the water supply and distribution pipes, fixtures, drainage pipes, vents, and related appurtenances installed in a building.

  • "Potable water" is water free from impurities in amounts that could cause disease or harmful physiological effects.

  • A "cross-connection" is any actual or potential physical connection between a potable water supply and a nonpotable source.

  • "Backflow" is the reverse flow of water or other substances into the potable water system from a nonpotable source.

  • An "air gap" is the unobstructed vertical distance between the lowest opening of a water outlet and the flood level rim of the fixture it supplies.

  • A "fixture unit" is a measure of the probable load that a plumbing fixture imposes on the drainage system or water supply system.

  • A "trap" is a fitting that retains a water seal to prevent sewer gas from entering a building.

  • "Developed length" is the length measured along the centerline of pipe and fittings, including allowances for fittings.

Quick reference

Fixtures, Fixture Fittings, and Water Heaters

  • Water closets require at least 15 inches from centerline to sidewall, 15 inches between adjacent fixtures, and 21 inches in front of the fixture.

  • Each fixture trap must have a water seal of at least 2 inches and not more than 4 inches.

  • Water heaters require a temperature and pressure relief valve, and the discharge pipe must be full size, gravity-drained, and terminate in a safe location.

  • The relief valve discharge pipe must not be reduced in size and must not contain valves or traps.

  • Water heaters installed in garages must have ignition sources elevated at least 18 inches above the floor unless listed as flammable vapor ignition resistant.

  • Hose bibbs and similar outlets require backflow protection such as a vacuum breaker where a hose can be connected.

  • Grease interceptors are required for many food service establishments to separate fats, oils, and grease from wastewater before discharge.

  • Fixtures must be installed with clearance for cleaning and use, and fixtures must be accessible for inspection and repair.

Quick reference

Water Supply and Distribution

  • Minimum fixture supply pressure is typically 8 psi for tank-type fixtures and 15 psi for flushometer valves.

  • Static water pressure exceeding 80 psi requires a pressure-reducing valve to protect the plumbing system.

  • Maximum water velocity in distribution piping is commonly 8 feet per second for cold water and 5 feet per second for hot water.

  • Backflow prevention must match the hazard; air gaps and reduced pressure zone assemblies provide high-hazard protection.

  • Water service pipes must be buried below the frost line or otherwise protected from freezing.

  • A thermal expansion tank is required on a closed water heater system to absorb expanded water and prevent excessive pressure.

  • Water distribution piping is sized using fixture units, developed length, pressure available, and elevation changes.

  • The water supply system must be tested under working pressure or with air, and leaks must be repaired before approval.

Quick reference

Sanitary Drainage, Traps, and Vents

  • Horizontal drainage pipe must slope at least 1/4 inch per foot for 2 1/2 inch and smaller pipe, and 1/8 inch per foot for 3 inch and larger pipe.

  • Drainage pipe size must not be reduced in the direction of flow.

  • Trap seals must be at least 2 inches and not more than 4 inches deep.

  • The trap arm length between a trap and its vent is limited by code and depends on the trap size.

  • Cleanouts are required at the base of stacks, at changes of direction of 135 degrees or more, and at specified horizontal intervals such as every 100 feet.

  • Vent pipes must extend at least 6 inches above the roof and must be located away from windows, doors, and air intakes.

  • A wet vent serves as both a drain and a vent and is permitted only where the code allows and when properly sized.

  • A backwater valve may be required where fixtures are subject to sewage backflow from a surcharging public sewer.

  • Air admittance valves may be used only where permitted by the code and must be installed in accessible locations.

Quick reference

Storm Drainage and Special Plumbing Systems

  • Storm water must discharge to an approved storm drainage system or receiving water and must not connect to a sanitary sewer unless an approved combined system exists.

  • Roof drains are sized using the roof area and the local design rainfall rate.

  • Roofs with parapet walls often require secondary drainage such as overflow drains or scuppers to handle rainwater if primary drains block.

  • Storm drainage piping must be sized and sloped so that water drains freely without ponding on the roof.

  • Sump pumps must discharge to an approved location and must not discharge to the sanitary sewer without approval.

  • Special plumbing systems such as nonpotable water systems must be identified and protected against cross-connections with potable water.

  • Subsoil drains collect groundwater and must discharge to an approved location.