ICC P2 flashcards
ICC P2 · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Plumbing permit
- Official authorization required before installing or altering a plumbing system, except for minor repairs listed in the code; work without it is a violation.
- Stop-work order
- Written notice requiring work to halt when the code official finds work unsafe, contrary to code, or without a permit; work resumes only after rescission.
- Final inspection
- Inspection after plumbing work is complete and accessible; approval is needed before the system is placed in service or occupancy is allowed.
- Board of appeals
- Local body that hears appeals of code official decisions and may grant variances only when strict application causes practical difficulty.
- Approved plans
- Plans reviewed and stamped by the code official; plumbing must be installed in accordance with them, and changes require reapproval.
- Approved
- A material, method, or product acceptable to the code official because it conforms to the code or an approved standard.
- Potable water
- Water free from impurities in quantities that could cause disease or harmful physiological effects, acceptable for drinking and domestic use.
- Cross-connection
- Any actual or potential physical connection between a potable water supply and a nonpotable source that could allow contamination.
- Air gap
- Unobstructed vertical distance between the lowest opening of a water outlet and the flood level rim of the fixture it supplies.
- Fixture unit
- A dimensionless measure of the probable load a plumbing fixture places on the drainage system or water supply system.
- Water closet clearance
- At least 15 inches from centerline to sidewall, 15 inches to adjacent fixture, and 21 inches in front to wall or obstruction.
- Trap seal
- Vertical depth of water in a trap that prevents sewer gas from entering the building; must be between 2 and 4 inches.
- T&P relief valve
- Device on a water heater that opens at excessive temperature or pressure to prevent explosion; discharge must be piped to a safe location.
- Hose bibb vacuum breaker
- Backflow preventer installed on a hose connection to stop contaminated water from being siphoned into the potable water supply.
- Flammable vapor ignition
- Water heaters in garages must be elevated 18 inches above the floor unless listed as flammable vapor ignition resistant.
- Grease interceptor
- Plumbing appurtenance that separates fats, oils, and grease from wastewater before discharge, required for many food service establishments.
- Residual pressure
- Pressure remaining at a fixture or outlet while water flows; code sets minimums such as 8 psi for tank-type water closets.
- Pressure-reducing valve
- Device required when static water pressure exceeds 80 psi to lower pressure and protect the plumbing system.
- RPZ assembly
- Reduced pressure zone backflow preventer providing high-hazard protection; includes two check valves and a relief valve.
- Water service pipe
- Pipe from the water main or source to the building, sized for demand and buried below frost line or protected.
- Thermal expansion tank
- Device installed on a closed water heater system to absorb expanded water and prevent excessive pressure.
- Velocity limit
- Maximum water flow speed in distribution piping, commonly 8 fps for cold water and 5 fps for hot water.
- Drainage slope
- Horizontal drainage pipe must slope 1/4 inch per foot for 2 1/2 inch and smaller, and 1/8 inch per foot for 3 inch and larger.
- Trap arm
- Pipe section between a fixture trap and its vent; its maximum length depends on trap size and is limited by code.
- Cleanout
- Access opening in a drainage pipe for clearing stoppages; required at base of stacks and at specified intervals and changes of direction.
- Vent termination
- Vent pipe must extend at least 6 inches above the roof and away from windows, doors, or air intakes.
- Backwater valve
- Device installed on a drainage line to prevent sewage from reversing into the building when the public sewer surcharges.
- Wet vent
- A vent that also serves as a drain for one or more fixtures, allowed only where code permits and sized accordingly.
- Roof drain
- Drain fitting that receives rainwater from a roof and connects to storm drainage piping sized by roof area and rainfall rate.
- Secondary roof drainage
- Backup drainage such as overflow drains or scuppers required to handle rainwater if primary roof drains become blocked.
- Storm sewer connection
- Storm drainage must discharge to an approved storm system or receiving water and must not connect to the sanitary sewer unless approved.
- Sump pump
- Pump that removes accumulated water from a sump or pit and discharges it to an approved location, not the sanitary sewer without approval.