ICC Commercial B2 · Get comfortable with the vocabulary.

Occupancy Classification

The process of assigning a building or portion of it to a use group based on the character of the activities expected inside, which then sets allowable height, area, egress, and fire protection requirements.

Related: Use Group, Mixed Occupancy
Use Group

A lettered category such as A, B, E, F, I, M, R, S, or U that groups buildings by hazard and function, controlling which code provisions apply to each part of a structure.

Related: Occupancy Classification, Incidental Use Area
Mixed Occupancy

A building containing two or more use groups, either separated by fire barriers that allow each part to be treated independently or treated as a single nonseparated occupancy with stricter overall limits.

Related: Use Group, Fire Barrier
Incidental Use Area

A space of a secondary function, such as a boiler room or storage room, that is accessory to the main occupancy and must be separated from it by fire-resistant construction of a specified rating.

Related: Use Group, Fire Partition
Type of Construction

The classification, Type I through Type V, describing how much fire resistance the structural frame, exterior walls, and floor and roof assemblies must have, with subtypes A and B for noncombustible types.

Related: Fire-Resistance Rating, Allowable Building Area
Allowable Building Area

The maximum floor area permitted per story, found in a table indexed by construction type and occupancy, then adjusted for frontage, sprinklers, and multistory conditions.

Related: Type of Construction, Frontage Increase
Allowable Building Height

The maximum number of stories and feet above grade permitted for a given construction type and occupancy, determined from tables and modified by automatic sprinkler protection.

Related: Type of Construction, Mezzanine
Frontage Increase

An allowance that increases permitted building area when the building perimeter faces a public way or open space of adequate width, rewarding sites with more accessible exterior exposure.

Related: Allowable Building Area, Open Space
Mezzanine

An intermediate level within a room or story, limited in area relative to the floor below, that is not counted as a story and is treated as part of the space it occupies.

Related: Allowable Building Height, Floor Area
Floor Area, Gross

The area within the surrounding exterior walls of a building or portion of it, used in calculations of allowable area, occupant load, and other code thresholds.

Related: Allowable Building Area, Occupant Load
Occupant Load

The total number of persons a space is designed to hold, calculated by dividing floor area by a use-specific factor or by counting fixed seats, and used to size exits.

Related: Egress Width, Means of Egress
Means of Egress

A continuous and unobstructed path of travel from any point in a building to a public way, comprising the exit access, the exit, and the exit discharge.

Related: Exit Access, Exit Discharge
Exit Access

The portion of the egress path that leads from the occupied space to an exit, including aisles, corridors, and the travel distance before reaching a protected exit.

Related: Means of Egress, Travel Distance
Exit Discharge

The portion of the egress system between the exit and the public way, often a lobby, vestibule, or exterior court that must remain open and unobstructed.

Related: Means of Egress, Exit Access
Travel Distance

The measured length along the natural path of travel from the most remote point in a space to an exit, limited by occupancy and sprinkler protection.

Related: Exit Access, Common Path of Egress Travel
Common Path of Egress Travel

The distance a occupant must travel before reaching a point where two separate routes to exits become available, limited to keep single-direction travel short.

Related: Travel Distance, Exit Access
Egress Width

The clear width of an exit component, sized by multiplying occupant load by a capacity factor, with minimums for corridors, stairs, and doors.

Related: Occupant Load, Means of Egress
Accessible Route

A continuous, unobstructed path connecting accessible elements and spaces, complying with slope, width, surface, and change-of-level requirements so people with disabilities can use the building.

Related: Accessible Means of Egress, Clear Floor Space
Accessible Means of Egress

A path of travel usable by persons with disabilities, including areas of refuge and accessible routes to them, required where the building is not fully sprinklered or otherwise exempted.

Related: Area of Refuge, Accessible Route
Area of Refuge

A space protected from fire and smoke where persons unable to use stairs can wait for assistance, typically adjacent to an exit stairway and equipped with two-way communication.

Related: Accessible Means of Egress, Exit Stairway
Fire-Resistance Rating

The period, in hours or fractions of an hour, that a building element resists fire exposure when tested to a standard fire test, expressed on assemblies and structural members.

Related: Fire Barrier, Type of Construction
Fire Barrier

A fire-resistance-rated wall assembly, continuous from floor to floor or roof, designed to restrict the spread of fire and typically used to separate occupancies or exit enclosures.

Related: Fire Partition, Fire-Resistance Rating
Fire Partition

A fire-resistance-rated wall with a lower rating than a fire barrier, used to separate dwelling units, guest rooms, or corridors from other spaces within a story.

Related: Fire Barrier, Smoke Barrier
Smoke Barrier

A continuous membrane or assembly designed to resist the passage of smoke, used to protect means of egress and smoke compartments in occupancies such as health care and malls.

Related: Smoke Compartment, Fire Barrier
Smoke Compartment

A space enclosed by smoke barriers so that smoke migration is limited, allowing occupants to relocate horizontally to a protected zone during a fire.

Related: Smoke Barrier, Area of Refuge
Interior Finish Classification

The rating of wall and ceiling materials as Class A, B, or C based on flame spread and smoke development in a standard test, with limits varying by occupancy and location.

Related: Flame Spread Index, Smoke-Developed Index
Flame Spread Index

A numerical result from a standard surface burning test that ranks how quickly flames spread across a material, used to assign interior finish classes.

Related: Interior Finish Classification, Smoke-Developed Index
Smoke-Developed Index

A numerical result from the same surface burning test measuring how much smoke a material produces, used alongside flame spread to classify interior finishes.

Related: Flame Spread Index, Interior Finish Classification
Structural Frame

The columns, girders, beams, trusses, and other members that support floors and roofs, required to have fire resistance based on the building construction type.

Related: Type of Construction, Fire-Resistance Rating
Live Load

The load produced by occupancy and use, including people, furniture, and movable equipment, assigned values by occupancy in the structural design provisions.

Related: Dead Load, Load Combinations
Dead Load

The permanent weight of the building itself, including structure, finishes, partitions, and fixed equipment, that the structural system must carry throughout its life.

Related: Live Load, Load Combinations
Load Combinations

Prescribed ways of adding dead, live, wind, seismic, snow, and other loads together with factors to ensure the structure performs safely under realistic worst cases.

Related: Live Load, Dead Load
Foundation

The system of footings, piles, mats, or walls that transfers building loads to the ground, designed using soil bearing capacity and settlement considerations from a geotechnical report.

Related: Footing, Allowable Soil Bearing Pressure
Footing

The widened base of a foundation element that spreads structural loads over a larger soil area to keep bearing pressure within allowable limits.

Related: Foundation, Allowable Soil Bearing Pressure
Allowable Soil Bearing Pressure

The maximum pressure a soil can safely support, usually established by geotechnical investigation and used to size footings and other foundation elements.

Related: Footing, Foundation
Building Envelope

The exterior shell of a building, including walls, roofs, windows, doors, and foundations, that separates conditioned interior space from the outdoors and controls heat, air, and moisture.

Related: Thermal Envelope, Air Barrier
Thermal Envelope

The boundary of the conditioned space, defined by insulation, glazing, and sealed assemblies, that determines where energy code requirements for heat transfer apply.

Related: Building Envelope, U-Factor
U-Factor

A measure of how readily an assembly conducts heat, equal to the inverse of its R-value, used in energy code tables to limit heat loss through walls, roofs, and windows.

Related: R-Value, Thermal Envelope
R-Value

A measure of thermal resistance, indicating how well a material or assembly slows heat flow, with higher values meaning better insulating performance.

Related: U-Factor, Thermal Envelope
Air Barrier

A continuous system of materials that resists uncontrolled air leakage through the building envelope, required to be sealed and verified in energy code compliance.

Related: Building Envelope, Thermal Envelope
Vapor Retarder

A material installed to slow the movement of water vapor through building assemblies, placed according to climate to reduce condensation and moisture damage.

Related: Building Envelope, Air Barrier
Daylight Responsive Control

A device that automatically adjusts artificial lighting output in response to available daylight, required in certain spaces to reduce energy use.

Related: Occupancy Sensor, Lighting Power Density
Lighting Power Density

The maximum permitted lighting wattage per unit of floor area, used by the energy code to limit installed lighting power in buildings and spaces.

Related: Daylight Responsive Control, Occupancy Sensor
Occupancy Sensor

A control that turns lights off or reduces them when a space is unoccupied, required in many rooms as part of energy code lighting controls.

Related: Daylight Responsive Control, Lighting Power Density
Special Construction

Building elements outside conventional scope, such as membrane structures, towers, and pedestrian walkways, governed by dedicated code chapters with their own criteria.

Related: Building Envelope, Type of Construction