ICC F1 flashcards
ICC F1 · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Fire code official authority
- The fire code official enforces the fire code, may inspect premises at reasonable times, issue permits, and order correction of violations or hazardous conditions.
- Operational permit
- A permit for an ongoing activity rather than construction, such as an assembly occupancy, hazardous material storage, hot work, or open burning.
- Certificate of occupancy
- Issued before a building may be occupied; it verifies the structure meets code for its classified occupancy group and intended use.
- Board of appeals
- Body that hears appeals of fire code official decisions; applications typically must be filed within 30 days of the decision being appealed.
- Stop work order
- A written order directing that work contrary to code cease; the work may not resume until the fire code official authorizes it.
- Imminent danger authority
- The fire code official may order immediate evacuation or closing of a premises that presents an imminent danger to life or property.
- Group A occupancy
- Assembly occupancy for gatherings of 50 or more persons, subdivided A-1 through A-5 into theaters, restaurants, worship, arenas, and outdoor venues.
- Group H occupancy
- High-hazard occupancy involving quantities of hazardous materials above code limits, subdivided H-1 through H-5 by material type and degree of hazard.
- Group I-2 occupancy
- Institutional occupancy providing medical or custodial care where occupants are incapable of self-preservation, such as hospitals and nursing homes.
- Occupant load factor
- Floor area per occupant taken from Table 1004.5; occupant load equals floor area divided by the factor, using net or gross area as specified.
- Accessory occupancy
- A subordinate use incidental to the main occupancy; allowed only within limited area and height, otherwise classified as a mixed occupancy.
- Mixed occupancy methods
- Multiple occupancies in one building are handled by the separated method with rated separations, or the nonseparated method where the most restrictive requirements govern.
- Change of occupancy
- A new use that requires evaluation against requirements for the new occupancy group, including egress, fire protection, height, and area limits.
- Means of egress components
- The continuous path from any point in a building to the public way: exit access, the exit, and exit discharge, each unobstructed and sized for the load.
- Type I-A construction
- The most fire-resistive construction type; the structural frame typically requires 3-hour protection, with 2-hour floors and heavily rated exterior walls.
- Egress width factors
- Capacity sizing uses 0.2 inch per occupant for doors and level egress components, and 0.3 inch per occupant for stairways.
- Common path of travel
- The portion of exit access where occupants must travel in a single direction before two distinct paths to exits become available.
- Dead-end corridor
- A corridor segment with only one direction of escape; limited to 20 feet, with limited sprinklered exceptions extending to 50 feet.
- Panic hardware requirement
- Doors serving 50 or more occupants in Group A or Group E occupancies must have panic hardware and swing in the direction of travel.
- Travel distance measurement
- Measured along the natural, unobstructed path of travel from the most remote point on a floor to the nearest exit door.
- Sprinkler deflector clearance
- Deflectors must be at least 18 inches below the ceiling unless listed for a reduced clearance, and storage cannot obstruct the sprinkler spray pattern.
- NFPA 13R system
- Sprinkler standard for residential occupancies up to four stories in height; it omits some protections that a full NFPA 13 system would require.
- Class K extinguisher
- Required in cooking areas involving vegetable or animal oils; the travel distance from the cooking appliance to the extinguisher is limited to 30 feet.
- Manual fire alarm box
- Located within 5 feet of each required exit door and within 200 feet of travel distance from any point on the floor it serves.
- Fire apparatus access road
- Must be at least 20 feet wide, provide 13.5 feet of vertical clearance, and be positioned within 150 feet of the building.
- Standpipe Class I
- Provides 2.5-inch outlets intended for fire department hose use, required in buildings based on height and floor area thresholds.
- NFPA 704 diamond
- Hazard marking using blue for health, red for flammability, yellow for instability, and white for special hazards such as oxidizers or water reactivity.
- Class I flammable liquid
- A liquid with a flash point below 100 F, subdivided into IA, IB, and IC by flash point and boiling point ranges.
- Maximum allowable quantity
- The amount of a hazardous material permitted per control area before additional permits, separation, and protection requirements are triggered.
- Extinguisher inspection schedule
- Extinguishers require a monthly visual inspection, annual maintenance, a 6-year internal examination, and a 12-year hydrostatic test.
- Occupant load posting
- Group A, Group B, and other occupancies as required must post the occupant load conspicuously near the main exit of the space.
- Inspection report contents
- Records the date, inspector, address, occupancy, code section violated, condition observed, corrective action required, and the reinspection date.