ICC F2 flashcards
ICC F2 · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Fire Code Official Authority
- The fire code official enforces the code, issues permits, conducts inspections, and may order correction of hazardous conditions or stop work.
- Permit Required
- A permit is required for operations such as open burning, fireworks, flammable liquid storage, and installation of fire protection systems.
- Inspection Warrant
- If entry is refused, the fire code official may seek an inspection warrant to conduct a required inspection.
- Notice of Violation
- A written notice must specify the code section violated, the corrective action required, and a compliance deadline.
- Stop-Work Order
- Issued when work proceeds without a required permit or violates approved plans; work must cease immediately.
- Board of Appeals
- A board that reviews appeals of fire code official decisions; appeals must be filed within a specified time, often 30 days.
- Penalties for Violations
- Violations may result in fines, imprisonment, or both; each day of violation may be a separate offense.
- Combustible Waste Storage
- Must be stored in approved containers and removed from the premises at frequent intervals to prevent fire spread.
- Hot Work Prohibition
- Open flames, smoking, and hot work are prohibited in areas where flammable vapors or dusts may be present.
- Fire Lane Maintenance
- Fire lanes and apparatus access roads must be kept clear and marked; parking is prohibited to ensure emergency access.
- Exit Sign Illumination
- Exit signs must be illuminated and visible; emergency lighting must provide illumination for at least 90 minutes.
- Hydrant Clear Space
- Fire hydrants must be accessible and maintained with a clear space of at least 3 feet (914 mm) around them.
- Flammable Liquid Storage
- Flammable and combustible liquids must be stored in approved containers and cabinets, with limits on quantities per control area.
- Combustible Decorations Limits
- In means of egress, combustible decorations are limited to 10% of wall area unless sprinklered, and must not obstruct exits.
- Type I Construction
- Noncombustible construction with high fire-resistance ratings, such as a 2-hour structural frame, used for high-rise buildings.
- Type V Construction
- Wood-frame construction with the most restrictive allowable heights and areas due to combustible materials.
- Fire Wall Rating
- A fire wall must have a fire-resistance rating of at least 2 hours and extend continuously from foundation to roof.
- Fire Barrier Rating
- Fire barriers separating different occupancies typically require a 1-hour or 2-hour rating depending on the occupancy classification.
- Opening Protectives
- Fire doors and fire windows must have a fire-protection rating corresponding to the fire-resistance rating of the wall.
- Fireblocking
- Required in concealed spaces to inhibit the spread of fire; draftstopping is required in floor/ceiling assemblies.
- Allowable Area Increases
- The allowable area of a building may be increased with sprinklers, frontage, and separation distances per code formulas.
- Sprinkler Design Density
- Automatic sprinkler systems must be designed to provide a minimum density (gpm/ft²) over a specified area of operation.
- Water Supply Requirements
- Sprinkler systems require a water supply with adequate pressure and duration; fire flow is based on building size and occupancy.
- Standpipe System Requirement
- Standpipes are required in buildings where the highest floor is more than 30 feet above fire department access.
- Fire Alarm Monitoring
- Fire alarm systems must be monitored by an approved supervising station or provide equivalent protection.
- Extinguisher Selection
- Portable fire extinguishers must be selected based on hazard class (A, B, C, D, K) and located within specified travel distances.
- Hazardous Materials Limits
- Storage limits are based on physical state, flash point, and toxicity, and are tabulated by control area.
- Sprinkler Control Valves
- Control valves must be supervised and clearly identified; main drain tests verify water supply adequacy.
- Means of Egress Components
- The means of egress consists of three parts: exit access, exit, and exit discharge.
- Number of Exits
- At least two exits are required for most occupancies; one exit is allowed for small spaces with limited occupant load and travel distance.
- Travel Distance Limits
- Travel distance to an exit is limited (e.g., 200 feet for unsprinklered business occupancies) and may be increased with sprinklers.
- Exit Door Swing
- Exit doors must swing in the direction of egress travel when serving an occupant load of 50 or more.
- Interior Finish Classification
- Interior finish is classified by flame spread index: Class A (0-25), Class B (26-75), Class C (76-200).