Permit exemption
Ordinary repairs and routine maintenance that do not alter the mechanical system's size, location, or type generally do not require a mechanical permit.
Construction documents
Scaled drawings and specifications submitted with a permit application that show the size, location, type, and details of the mechanical equipment and distribution systems.
Rough-in inspection
An inspection performed after the mechanical system is installed but before concealment by building finishes, verifying compliance before work is covered.
Stop-work order
A written notice issued by the code official that halts work on a project because the work is unsafe, noncompliant, or proceeding without required permits.
Listed material
Equipment or material included in a published list by an approved agency that maintains periodic inspection of production and certifies compliance with a standard.
Board of appeals
A body established by the adopting jurisdiction that hears and decides appeals of decisions made by the code official under the mechanical code.
Garage appliance ignition height
Ignition sources of appliances installed in private garages must be elevated at least 18 inches above the floor unless the appliance is listed for garage installation.
Equipment working clearance
A clear working space of at least 30 inches wide and 30 inches deep is generally required in front of heating and cooling equipment, or the larger manufacturer clearance.
Condensate drain trap
A trap on a cooling coil drain that prevents air from being drawn through the drain line, with discharge to an approved receptor.
Secondary drain protection
A secondary drain line or an overflow pan equipped with a switch that shuts off the unit when condensate accumulates, protecting the building from water damage.
Return air prohibition
Return air must not be drawn from bathrooms, kitchens, closets, or from one dwelling unit to serve another dwelling unit.
Attic appliance access
Appliances installed in attics require a permanently installed walkway or service platform and a lighting outlet near the service access point.
Outdoor unit clearance
Outdoor condensing units must be installed with airflow and service clearances specified by the manufacturer's listed instructions.
Bathroom exhaust discharge
Exhaust from bathrooms and toilet rooms must terminate outdoors and must not discharge into attics, crawl spaces, or other interior areas.
Dryer duct fasteners
Screws or fasteners that penetrate the interior of a clothes dryer exhaust duct are prohibited because they can collect lint and block airflow.
Dryer duct termination
Clothes dryer exhaust ducts must terminate outdoors with a backdraft damper and within the developed length limits established by the manufacturer and code.
Type I hood
A commercial kitchen hood designed to capture grease and smoke, requiring grease duct enclosure, clearance to combustibles, and a fire suppression system.
Type II hood
A commercial kitchen hood for capturing heat, moisture, and odors without grease or smoke, and it does not require grease duct protection.
Makeup air
Air supplied to replace air removed by exhaust systems, provided in quantities that maintain required pressure relationships and safe appliance draft.
Hazardous exhaust separation
Exhaust ducts conveying hazardous or noxious contaminants must not connect to other exhaust systems and must discharge where building openings are protected.
Duct insulation vapor retarder
Ducts in unconditioned spaces require insulation to the specified R-value with a vapor retarder on the exterior to limit condensation.
Flexible duct support
Factory-made flexible duct must be supported at intervals not exceeding 4 feet and installed without sharp bends or compression that restricts airflow.
Fire damper
A listed device installed in a duct penetration of a fire-rated assembly that closes on fire exposure to maintain the assembly's fire resistance rating.
Outdoor combustion air openings
Two permanent openings to outdoors are sized using the code's free-area ratio applied to the total Btu/h input rating of appliances in the space.
Indoor combustion air volume
Where combustion air is drawn from indoors, the space must meet the minimum volume per Btu/h of appliance input or be provided with outdoor air.
Duct sealing
Duct joints, seams, and connections must be sealed with approved materials, and tapes and mastics must be listed for the application.
Vent connector slope
A vent connector must slope upward toward the chimney at the code-required rate and must not be smaller than the appliance flue collar.
Category I appliance
A gas appliance that operates with negative vent pressure and produces flue gases that stay above the dew point, vented through a properly sized vertical vent.
Category IV appliance
A gas appliance that operates under positive vent pressure and produces corrosive condensate, requiring listed positive-pressure venting.
Vent termination height
The required height of a vent termination above the roof is determined by the roof pitch and its proximity to walls, dormers, and air intakes.
Refrigerant safety group
A classification of refrigerants by toxicity and flammability that determines allowable charge quantities and required safety provisions in occupied spaces.
Refrigeration machinery room
A room containing refrigeration equipment that must meet ventilation, refrigerant detection, and access requirements based on refrigerant class and charge.