Structural Steel Bolting and Connection Inspection

Bolted connection inspection verifies that the correct bolt, hole, joint preparation, and pretensioning method were used. High-strength bolts are typically ASTM F3125, which consolidated A325 and A490; grade markings, lubricant, washers, and coating must match the specification. The inspector checks hole type and alignment, faying-surface condition, snugging, pretensioning, and final condition.

Pretensioning methods

  • Turn-of-nut: snug the joint, match-mark, then apply the code-required rotation.
  • Calibrated wrench: verify daily with a tension calibrator.
  • DTI: compress the washer gaps to the specified feeler-gauge limit.
  • Twist-off: tighten until the splined end shears.

Worked example

A turn-of-nut joint uses bolts shorter than four diameters. After snugging and match-marking, the crew applies the required one-third turn. The inspector verifies that all match marks show the full rotation and that the joint was snugged first. Reasoning: rotation applied before snugging is not pretension; the match marks document the actual rotation.

Traps

  • Counting impact-wrench “tightening” as pretension without a qualified method.
  • Inspecting rotation without verifying snugging.
  • Using damaged or mismatched DTI washers.
  • Painting faying surfaces with a coating not qualified for slip-critical service.
  • Ignoring oversized or slotted holes and cover plates.