Authorized Gas Tester (AGT) study materials
Authorized Gas Tester (AGT) study resources

Authorized Gas Tester (AGT) key terms

Authorized Gas Tester (AGT) · Get comfortable with the vocabulary.

Lower Explosive Limit (LEL)

The lowest concentration of a flammable gas or vapour in air at which a flame will still propagate through the mixture. Below this figure the mixture is too lean to burn, so readings are usually expressed as a percentage of this value.

Related: Upper Explosive Limit (UEL), Flammable Range
Upper Explosive Limit (UEL)

The highest concentration of a flammable gas or vapour in air that will still support flame propagation. Above this figure the mixture is too rich to burn, but dilution with air can bring it back into the flammable range.

Related: Lower Explosive Limit (LEL), Flammable Range
Flammable Range

The band of concentrations between the lower and upper explosive limits within which a gas or vapour mixed with air can ignite. Any reading inside this band represents an immediate fire or explosion risk.

Related: Lower Explosive Limit (LEL), Upper Explosive Limit (UEL)
Flash Point

The lowest temperature at which a liquid gives off enough vapour to form an ignitable mixture with air near its surface. Liquids with low flash points generate flammable atmospheres at ordinary working temperatures.

Related: Vapour Density, Auto-ignition Temperature
Auto-ignition Temperature

The lowest temperature at which a substance will ignite spontaneously in air without any external ignition source. Hot surfaces, such as exhausts or steam lines, can therefore ignite vapours even when no spark is present.

Related: Flash Point, Ignition Source
Vapour Density

The mass of a vapour compared with an equal volume of air at the same conditions. Values above one mean the gas tends to sink and collect in low-lying areas, pits, sumps and drains, which affects where samples must be taken.

Related: Stratification, Density
Density (Relative to Air)

How heavy a gas is compared with air, usually expressed as a ratio. Gases heavier than air accumulate at low points and lighter gases rise and gather near the roof, so this property drives sampling-point placement.

Related: Vapour Density, Stratification
Stratification

Layering of gases or vapours of different densities within an enclosed space, so that composition varies with height. A single sample at one level may miss a pocket of flammable or toxic gas elsewhere in the space.

Related: Vapour Density, Sample Point
Ignition Source

Any energy input capable of starting combustion, such as sparks, flames, hot work, static discharge, hot surfaces or non-intrinsically safe equipment. Identifying and controlling these is central to hot work and flammable-atmosphere planning.

Related: Auto-ignition Temperature, Hot Work
Toxic Gas

A gas or vapour that harms health when inhaled, even at low concentrations, for example hydrogen sulphide or carbon monoxide. Toxic limits are set separately from flammability limits and require their own measurement and controls.

Related: Occupational Exposure Limit, Oxygen Deficiency
Occupational Exposure Limit (OEL)

A regulatory or advisory airborne concentration considered safe for a worker over a defined exposure period, such as an eight-hour time-weighted average or a short-term limit. Gas detector alarm points are often based on these values.

Related: Toxic Gas, Time-Weighted Average
Time-Weighted Average (TWA)

The average concentration of a substance in air over a reference period, usually eight hours, reflecting total inhaled dose rather than peak level. It is used to judge whether long-term exposure to a toxic gas is acceptable.

Related: Occupational Exposure Limit, Short-Term Exposure Limit
Short-Term Exposure Limit (STEL)

The maximum average concentration permitted for a short period, commonly fifteen minutes, that must not be repeated excessively during a shift. It protects against sudden peaks of toxic gas that a TWA alone would not control.

Related: Time-Weighted Average, Occupational Exposure Limit
Confined Space

An enclosure that is not designed for continuous occupancy and has limited or restricted entry and exit, where serious injury can arise from hazardous atmosphere, engulfment or other hazards. Entry normally requires testing and a permit.

Related: Permit to Work, Confined Space Entry
Permit to Work (PTW)

A formal written authorisation that defines the scope of a task, the hazards, the controls required and the conditions that must be met before and during the work. It is signed by authorised people and closed out on completion.

Related: Confined Space Entry, Hot Work Permit
Confined Space Entry

The act of entering a confined space, including any part of the body, to carry out work or inspection. Entry is only permitted under a valid permit, with atmosphere testing, isolation and rescue arrangements in place.

Related: Confined Space, Pre-entry Testing
Hot Work

Work that can produce flames, sparks, hot surfaces or sufficient heat to ignite a flammable atmosphere, including welding, grinding and cutting. It requires a specific permit, gas testing and fire precautions.

Related: Hot Work Permit, Ignition Source
Hot Work Permit

A permit issued for tasks that introduce ignition sources, stating the area, duration, fire watch, gas test results and precautions required. It confirms the area has been made safe and that monitoring will continue while work proceeds.

Related: Hot Work, Permit to Work (PTW)
Authorised Gas Tester (AGT)

A competent person trained and appointed to select and use gas detection equipment, perform tests, interpret results and record readings before and during work. The role carries responsibility for stopping work when conditions fall outside permitted limits.

Related: Pre-entry Testing, Bump Test
Risk Assessment

A systematic process of identifying hazards, evaluating who could be harmed and how, and deciding on controls and residual risk. For gas testing it determines which gases to test for, where, when and with what alarm levels.

Related: Safe System of Work, Permit to Work (PTW)
Safe System of Work

A documented combination of procedures, controls, equipment and supervision that makes a task safe. It links the risk assessment to practical steps such as isolation, purging, testing, monitoring, communication and rescue readiness.

Related: Risk Assessment, Permit to Work (PTW)
Pre-entry Testing

Atmospheric testing carried out before anyone enters a confined space, covering oxygen, flammable gas and likely toxic gases. It must be done from outside, at representative levels, and repeated if conditions change or after a break.

Related: Confined Space Entry, Continuous Monitoring
Continuous Monitoring

Ongoing measurement of the atmosphere with detectors worn or positioned in the space while work proceeds. It provides early warning of changing conditions, such as gas ingress or oxygen depletion caused by the work itself.

Related: Pre-entry Testing, Alarm Set Point
Oxygen Deficiency

An atmosphere containing less than about 19.5 per cent oxygen by volume, which can cause impaired judgement, breathlessness and loss of consciousness. It may result from displacement by other gases or from consumption by rusting, combustion or biological activity.

Related: Oxygen Enrichment, Inerting
Oxygen Enrichment

An atmosphere containing more than about 23.5 per cent oxygen by volume, which sharply increases the speed and severity of combustion. Clothing and hair can absorb oxygen and burn fiercely, so enrichment is a serious fire hazard.

Related: Oxygen Deficiency, Flammable Range
Inerting

Replacing air in a vessel or space with an inert gas such as nitrogen or carbon dioxide to exclude oxygen and prevent combustion. The resulting atmosphere is immediately dangerous to life because it will not support breathing.

Related: Oxygen Deficiency, Purging
Purging

Displacing an unwanted gas or vapour from a space by flushing with air, steam or inert gas before entry or hot work. Effective purging depends on adequate flow, time and venting, and must be verified by testing afterwards.

Related: Inerting, Pre-entry Testing
Catalytic Combustion Sensor

A detector element that burns flammable gas on a heated catalyst and measures the heat released to indicate concentration as a percentage of the lower explosive limit. It needs oxygen to work and can be poisoned or desensitised by certain substances.

Related: Infrared Sensor, Bump Test
Infrared (IR) Sensor

A detector that measures absorption of infrared light at characteristic wavelengths to quantify a gas. It can work in oxygen-free atmospheres and is used for flammable gas and carbon dioxide measurement, but is gas-specific and can be affected by humidity.

Related: Catalytic Combustion Sensor, Electrochemical Sensor
Electrochemical Sensor

A cell in which the target gas reacts at an electrode to produce a small current proportional to concentration. It is widely used for toxic gases and oxygen, has a finite life, and responds slowly at low temperatures.

Related: Toxic Gas, Oxygen Deficiency
Bump Test

A brief check in which a known test gas is applied to a detector to confirm that sensors respond and alarms activate. It verifies function but not accuracy, and is normally done before each use or shift.

Related: Calibration, Functional Check
Calibration

Adjusting a detector's response against a certified reference gas of known concentration so that readings are accurate. It is performed at defined intervals and after sensor replacement, and differs from a bump test or functional check.

Related: Bump Test, Zero Calibration
Functional Check

A verification that a detector's alarms, display, battery and sampling system operate correctly, without necessarily exposing sensors to gas. It complements bump testing and calibration in an equipment assurance programme.

Related: Bump Test, Calibration
Zero Calibration

Setting the detector to read zero in clean, fresh air or with a certified zero gas, so that the baseline is correct. A poor zero setting causes inaccurate readings, particularly for oxygen and toxic sensors.

Related: Calibration, Span Calibration
Alarm Set Point

The concentration at which a detector sounds a warning, chosen in advance from risk assessment, exposure limits or a percentage of the lower explosive limit. Two-stage alarms give early warning before conditions become dangerous.

Related: Continuous Monitoring, Occupational Exposure Limit (OEL)
Sample Point

A chosen location from which an atmosphere sample is drawn, selected because gas is likely to accumulate there. Correct placement uses knowledge of gas density, ventilation and the geometry of the space.

Related: Stratification, Vapour Density
Aspirated Detector

An instrument that draws a sample through a probe and hose to a remote sensor using a pump. Sample lines must be purged and checked for leaks, and the response time depends on hose length and flow rate.

Related: Sample Point, Calibration
Intrinsically Safe Equipment

Electrical apparatus designed so that its energy and temperature cannot ignite a flammable atmosphere, allowing safe use in hazardous areas. Certified gas detectors and torches used for testing must meet this requirement.

Related: Ignition Source, Hot Work
Emergency Rescue Arrangement

The planned means of recovering a casualty from a space, including trained rescuers, breathing apparatus, communications and access equipment. Untrained emergency entry is a common cause of multiple fatalities and must never be attempted.

Related: Confined Space Entry, Pre-entry Testing
Standby Person

A competent person stationed outside a confined space to maintain communication, monitor conditions, operate equipment and summon or assist rescue. They must not enter the space and must remain at the entry point until relieved.

Related: Emergency Rescue Arrangement, Confined Space Entry