ID Plumber flashcards
ID Plumber · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Fixture unit (drainage)
- A unit of measure expressing the probable load a fixture places on the drainage system; one drainage fixture unit equals 1 cubic foot per minute of flow, or 7.5 gallons per minute.
- Building drain
- The lowest pipe of a drainage system that receives soil and waste from inside the building and conveys it to the building sewer, which begins outside the foundation wall.
- Air gap
- An unobstructed vertical distance through free atmosphere between a potable water outlet and the flood-level rim of a receptor, equal to at least twice the pipe diameter or 1 inch, whichever is greater.
- Trap seal
- The vertical depth of water in a trap that prevents sewer gas from passing into the building; the seal must be at least 2 inches and not more than 4 inches deep.
- Grease interceptor
- A device that separates fats, oils, and grease from kitchen wastewater by gravity so that grease does not accumulate in the building drainage system or public sewer.
- Vent stack
- A vertical vent pipe that extends from the drainage stack to the outdoors, providing air to the drainage system and relieving pressure so trap seals are not siphoned.
- Developed length
- The total length of a pipe run measured along its centerline, including vertical and horizontal segments plus equivalent lengths for fittings and valves, used for sizing.
- Residual pressure
- The pressure remaining at a fixture or outlet while water is flowing; codes require a minimum of 8 psi at flush tanks and 15 psi at flushometer valves.
- Pressure-reducing valve
- A device installed where static water pressure exceeds 80 psi to reduce pressure to a safe level for the piping, fixtures, and appliances in the building.
- Backflow preventer
- A device or assembly that prevents the reverse flow of water into the potable supply; selection depends on the hazard level, and assemblies require annual testing.
- Temperature and pressure relief valve
- A safety valve on a water heater that opens when temperature or pressure exceeds set limits, with a discharge pipe terminating within 6 inches of the floor or to the exterior.
- Thermal expansion tank
- A tank installed on a closed water system to absorb the volume increase of heated water, preventing excessive pressure buildup and relief valve discharge.
- Water closet clearance
- The required spacing around a water closet: 15 inches from the centerline to a side wall and 30 inches of clear space in front of the fixture.
- High-efficiency toilet
- A water closet that flushes at 1.28 gallons or less per flush, compared with the standard maximum of 1.6 gallons per flush for water closets.
- Building sewer
- The pipe that carries sewage from the building drain, starting outside the building foundation, to the public sewer or private sewage disposal system.
- Cleanout
- An accessible fitting with a removable plug that allows a drain or sewer to be cleared; required at the base of stacks and at changes in direction over 45 degrees.
- Trap arm
- The portion of a fixture drain between the trap weir and the vent connection; its length is limited by trap size to prevent self-siphonage of the trap seal.
- Indirect waste receptor
- A fixture that receives wastewater from an indirect waste pipe through an air gap or air break, preventing backflow into the fixture or the potable water supply.
- Gray water
- Wastewater from lavatories, showers, bathtubs, and laundry that excludes toilet and kitchen sink waste, and may be reused for subsurface irrigation or flushing where approved.
- Reclaimed water
- Treated wastewater approved for nonpotable uses, conveyed in purple pipe with warning labels and separated from potable piping by approved backflow assemblies.
- Sediment trap
- A tee fitting with a capped nipple installed at the inlet of a gas appliance to collect debris and prevent it from entering the appliance controls.
- Gas pressure test
- A test of the gas piping system with air before it is placed in service; typical requirements are 10 psi for 30 minutes or 3 psi for 30 minutes depending on system pressure.
- Appliance connector
- A listed flexible connector that joins a gas appliance to the piping; it must not be concealed and cannot pass through walls, floors, or ceilings.
- Drainage slope
- The fall of a horizontal drain per unit of length; 2-inch and smaller pipe requires 1/4 inch per foot, while 3-inch and larger require at least 1/8 inch per foot.
- Rainfall to flow
- The conversion of roof area and rainfall intensity to flow: 1 inch per hour on 1 square foot equals 0.0104 cubic feet per second, or about 4.67 gallons per minute.
- Pipe volume formula
- The volume of water in a pipe in gallons equals 0.0408 times the diameter in inches squared times the length in feet; used for expansion and system sizing.
- First-hour rating
- The amount of hot water a water heater can supply in the first hour of use, starting with a full tank, used to match heater size to peak demand.
- Plan legend
- The key on a plumbing drawing that identifies symbols for water, drainage, vent, and gas lines, allowing the reader to interpret the piping layout correctly.
- Permit expiration
- A plumbing permit typically expires if work does not start within 180 days of issuance or is suspended for a set period, unless extended in writing.
- Authority having jurisdiction
- The organization or official responsible for enforcing the plumbing code, approving materials and methods, and conducting inspections of permitted work.
- Stop-work order
- A written notice issued by the code official requiring work to halt because it is unsafe or not in compliance, remaining in effect until corrected and re-inspected.
- Joist hole limit
- In solid sawn joists, bored holes must not exceed one-third the joist depth, must be located away from the middle third of the span, and at least 5/8 inch from edges.