OFTEC Solid Fuel flashcards
OFTEC Solid Fuel · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Stoichiometric air for kerosene
- Approximately 12.5 kg of air is needed to completely burn 1 kg of kerosene; flue CO2 near 12% indicates near-stoichiometric combustion with modest excess air.
- Smoke number interpretation
- Smoke number 0-1 indicates clean combustion, 2 is acceptable, and 3 or above indicates poor atomisation, incorrect air setting or a fouled appliance needing attention.
- Nozzle flow versus pressure
- Nozzle flow rate varies with the square root of pressure; doubling the pressure increases flow by a factor of about 1.41, not by two.
- Nozzle rating pressure
- Oil nozzle flow markings (such as 0.60) are US gallons per hour at the standard rating pressure of 100 psi, approximately 7 bar.
- Oil line vacuum limit
- Vacuum at the burner should not exceed about 0.4 bar (roughly 12 in Hg); higher values suggest a blocked filter, restricted line or faulty foot valve.
- Cad cell resistance meaning
- A photocell (cad cell) shows low resistance, typically under 1-2 kOhm, when it sees a good flame; high resistance indicates weak flame or a dirty cell.
- One-pipe versus two-pipe oil
- One-pipe lift systems with a de-aerator suit tanks below the burner; two-pipe gravity systems suit tanks above the burner where oil flows by gravity.
- Condensing boiler flue temperature
- For condensing operation the flue gas temperature should be only about 20-40 C above the boiler return temperature, keeping the appliance in condensing mode.
- Solid fuel combustion air
- Solid fuel appliances need a permanent, unobstructed combustion air supply, with a ventilator sized to the appliance's rated input as required by building regulations.
- Chimney draught principle
- Draught is created by the temperature difference between hot flue gases and outside air; a cold flue produces weak draught and poor appliance performance.
- Wood fuel moisture target
- Wood should be seasoned to around 20% moisture or lower; wetter fuel causes creosote and tar deposition and reduces net efficiency.
- Smoke control area fuels
- In smoke control areas only authorised smokeless fuels such as anthracite may be burned; bituminous coal is generally prohibited unless an exempt appliance is used.
- Open vent on solid fuel
- A solid fuel boiler must be arranged as an open-vented system with a cold feed and open vent; a closed unvented arrangement is unsafe.
- Solid fuel service tasks
- Servicing includes sweeping the flue, checking baffles, door gaskets and seals, and verifying the draught stabiliser operates correctly.
- Over-firing versus under-firing
- Over-firing from excessive primary air shortens appliance life; under-firing causes incomplete combustion, soot and creosote build-up in the flue.
- Flue termination requirement
- A solid fuel flue should terminate above the roof line and clear adjacent windows and openings in accordance with building regulations.
- Draught stabiliser function
- A draught stabiliser admits air to the flue to limit excessive draught, protecting the appliance from over-firing and improving combustion stability.
- RCD protection for heating
- Domestic final circuits are protected by 30 mA RCDs; a 6 A MCB commonly protects a 1.0-1.5 mm2 control or lighting circuit.
- Cable derating factors
- Cable current-carrying capacity must be derated for grouping, ambient temperature and thermal insulation using the factors given in BS 7671.
- Switched live versus permanent live
- The permanent live supplies power for pump overrun and frost protection, while the switched live comes from the programmer or room thermostat to call for heat.
- Earth loop impedance
- Earth loop impedance must be low enough for the protective device to disconnect within the required time at the prospective fault current.
- SELV control separation
- SELV controls such as 24 V or 0-10 V signals must be kept physically separate from mains wiring, with barriers and correct cable colours.
- Three-port valve mid-position
- A three-port mid-position valve can supply heating and hot water simultaneously when in its mid-position, unlike a two-port zone valve.
- Appliance isolation requirement
- Each heating appliance needs a means of functional switching and a double-pole isolator for safe maintenance isolation.
- Extraneous conductive part bonding
- Metallic pipework that is an extraneous conductive part must be main bonded; supplementary bonding may be needed in bathroom locations.
- Heat pump COP formula
- COP equals heat output in kW divided by electrical input in kW; the seasonal performance factor is the same ratio measured over a full season.
- Carnot COP limit
- The theoretical maximum COP equals T_hot divided by (T_hot minus T_cold), with both temperatures expressed in kelvin.
- Flow temperature and COP
- Lower flow temperatures, around 35-45 C, improve heat pump COP; underfloor heating suits these temperatures better than high-temperature radiators.
- Heat pump sizing basis
- A heat pump must be sized to the building's heat loss at the design external temperature, not simply to the rating of the existing boiler.
- Ground source collector choice
- Ground-source systems use horizontal collectors where land is available or boreholes where land is limited; loop length depends on ground thermal conductivity.
- Solar thermal orientation
- In the UK, solar thermal collectors are typically mounted facing south at a tilt of about 30-45 degrees to maximise annual yield.
- Thermal store purpose
- A thermal store buffers heat between generation and demand, helping heat pumps and biomass boilers run efficiently without short cycling.