SFP flashcards
SFP · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Triple bottom line
- Sustainability accounting framework that evaluates decisions against three bottom lines - social (people), environmental (planet), and economic (profit) - so facility choices are judged on combined impact rather than financial return alone.
- Materiality
- A topic is material when it significantly affects the organization's environmental, social, or economic performance and could influence stakeholder decisions; material topics determine what a sustainability report must prioritize.
- Sustainability charrette
- A facilitated workshop held early in project planning where owner, designers, operators, and community stakeholders agree on sustainability goals and performance targets before design decisions lock in cost and performance.
- ISO 14001
- International standard for environmental management systems built on Plan-Do-Check-Act; it requires an environmental policy, identification of aspects and impacts, a legal compliance register, objectives, and management review.
- Simple payback
- Simple payback in years equals initial project cost divided by annual savings; it ignores the time value of money, so it is paired with life-cycle cost or net present value for long-horizon facility investments.
- Influence-interest grid
- Stakeholder mapping tool: high influence plus high interest receives close engagement; high influence with low interest is kept satisfied; low influence with high interest is kept informed; low with low is monitored.
- GRI standards
- Global Reporting Initiative standards are a widely used framework for sustainability reporting; universal standards cover reporting principles and disclosures, with topic-specific standards for economic, environmental, and social subjects.
- GRESB benchmark
- Global ESG benchmark for real estate and infrastructure portfolios that scores funds and assets on management and performance indicators; institutional investors use it to compare sustainability performance across property portfolios.
- Green lease clause
- Lease provision allocating responsibility between landlord and tenant for energy data sharing, submetering, cost recovery of efficiency improvements, and minimum operating standards, so split incentives do not block upgrades.
- CDP disclosure
- Formerly the Carbon Disclosure Project: a disclosure system through which companies and cities report climate, water, and forest data to investors and customers using standardized questionnaires and a scoring methodology.
- Baseline year
- Reference year chosen for tracking energy, water, waste, or emissions performance; it must be representative and documented, and is recalculated when significant organizational or methodological changes occur.
- Life-cycle assessment
- Method that quantifies environmental impacts of a product or building across raw material extraction, manufacture, transport, use, maintenance, and end of life, using a defined functional unit and system boundary.
- Owner's Project Requirements
- Written document stating the owner's intended use, performance criteria, and expectations for a building; the commissioning process verifies that installed systems and assemblies satisfy it.
- Retro-commissioning
- Commissioning applied to an existing building that was never commissioned or has drifted from design; it investigates, tests, and tunes systems and produces a prioritized list of low-cost operational fixes.
- IPMVP Option C
- Measurement and verification approach using whole-building utility meter data compared against a weather- and occupancy-adjusted baseline to estimate total savings from an entire facility energy management program.
- Waste hierarchy
- Ordered preference for material management: prevent or reduce generation first, then reuse, then recycle or compost, then recover energy, and dispose in landfill only as a last resort.
- ASHRAE 62.1
- Ventilation standard for acceptable indoor air quality; it sets minimum outdoor air rates based on occupancy category and floor area and defines the ventilation rate procedure used in design and audits.
- ASHRAE 55
- Standard defining acceptable thermal comfort conditions from temperature, humidity, air speed, clothing, and metabolic rate, expressed through predicted mean vote and predicted percentage of dissatisfied occupants.
- LEED O+M
- LEED rating system for existing buildings in operation and maintenance; it awards points for measured energy and water performance, purchasing, waste, indoor environmental quality, and site management.
- Functional unit
- The quantified performance of a product or system used as the reference basis in a life-cycle assessment, allowing alternative options to be compared on an equivalent, defensible basis.
- Environmentally preferable purchasing
- Procurement that compares products on recycled content, energy and water use, emissions, durability, and end-of-life take-back, verified through specifications or third-party certifications rather than marketing claims.
- WELL Building Standard
- Certification focused on occupant health and well-being, with features covering air, water, light, thermal comfort, sound, materials, movement, and community rather than building energy performance.
- Energy use intensity
- Annual energy consumption divided by conditioned floor area, expressed in kBtu per square foot or kWh per square meter; it normalizes for building size so performance can be compared and trended.
- ENERGY STAR score
- A one-to-hundred rating from EPA Portfolio Manager comparing a building's weather-normalized source energy use with similar buildings; a score of 75 or higher qualifies for certification.
- Air-side economizer
- HVAC control that uses cool outdoor air for free cooling when outdoor temperature or enthalpy is below return air conditions, reducing mechanical cooling load during mild weather.
- Demand-controlled ventilation
- Control strategy that modulates outdoor air intake using carbon dioxide sensors or occupancy counters so ventilation tracks actual occupancy instead of design maximum, saving fan and conditioning energy.
- Lighting power density
- Installed lighting watts divided by floor area; energy codes cap it, and reducing it with LEDs and controls also lowers cooling load because lighting heat gain decreases.
- Integrated pest management
- Strategy that monitors pests and sets action thresholds, then applies sanitation, exclusion, and least-hazardous treatments before chemical pesticides, reducing occupant and environmental exposure.
- Green cleaning program
- Cleaning program using certified low-emission products, dilution control, microfiber tools, entryway matting, and procedure scheduling that protects indoor air quality and cleaning staff health.
- Cycles of concentration
- Ratio of dissolved solids in cooling tower water to those in makeup water; higher cycles reduce blowdown and water use but raise scaling risk, so conductivity and treatment are monitored together.
- Universal waste
- Regulated category for commonly generated hazardous items such as fluorescent lamps, batteries, and mercury thermostats, which carry simplified handling and recycling requirements instead of full hazardous waste rules.
- Measurement and verification
- Documented process using metered data and an adjusted baseline to quantify the savings actually delivered by an energy or water efficiency project, supporting budget justification and performance reporting.