IL Plumber flashcards
IL Plumber · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Illinois Plumbing Code citation
- The Illinois Plumbing Code is codified at 77 Ill. Adm. Code 890 and is administered by the Illinois Department of Public Health, which adopts and enforces its provisions statewide.
- Drainage fixture unit value
- A drainage fixture unit (DFU) expresses the load a fixture places on a drainage system; a water closet is 3 DFU, a lavatory 1 DFU, and a bathtub 2 DFU under the code tables.
- Trap arm length limit
- The developed length of a trap arm from the trap weir to the vent connection may not exceed the code table value, such as 5 feet for a 2-inch trap arm.
- Air gap definition
- An air gap is the unobstructed vertical distance between the lowest opening of a water supply outlet and the flood-level rim of a fixture or receptacle, providing absolute backflow protection.
- Minimum air gap dimension
- An air gap must be at least twice the effective diameter of the discharge pipe and never less than 1 inch above the flood-level rim of the receiving fixture.
- Vent terminal location
- A vent terminal must extend at least 2 inches above the roof and be located at least 10 feet from any window, door, or air intake, or 2 feet above the roof line if closer.
- Water closet clear space
- A water closet compartment must provide at least 15 inches from the bowl centerline to any side wall and at least 21 inches of clear space in front of the bowl.
- Building drain slope
- A building drain must slope at least 1/4 inch per foot for pipe 3 inches and smaller, and at least 1/8 inch per foot for pipe 4 inches and larger.
- Plumber license types
- Illinois issues apprentice, journeyman, and master plumber licenses; a master plumber may supervise work and serve as the responsible licensed plumber for a plumbing contractor.
- Plumbing contractor license
- A plumbing contractor license is issued to a business entity and requires a licensed plumber as the responsible person; the license is not transferable.
- Homeowner plumbing exemption
- A homeowner may perform plumbing work on a single-family residence the homeowner occupies, subject to permit and inspection requirements of the local authority.
- Licensing law citation
- The Illinois Plumbing License Law is 225 ILCS 320; it authorizes the Department of Public Health to license plumbers and to adopt rules for plumbing work.
- Apprentice supervision
- An apprentice plumber must work under the direct supervision of a licensed plumber and must accumulate the required experience hours before taking the journeyman examination.
- Grounds for discipline
- The Department may refuse, suspend, or revoke a license for gross negligence, incompetence, unlicensed practice, or fraud in obtaining a license, after a hearing.
- Permit requirement
- A plumbing permit must be obtained from the local authority having jurisdiction before new installation, alteration, or replacement of piping and fixtures begins.
- Plumber license renewal
- A plumber license must be renewed on the schedule set by the Department, and any applicable continuing education requirements must be satisfied before renewal is granted.
- Rough-in inspection
- Rough-in inspection occurs after piping is installed but before it is covered; the building drain and water distribution system must be tested and approved for concealment.
- Water system test pressure
- A water distribution system must be tested at working pressure or at least 100 psi for at least 30 minutes without loss of pressure before acceptance.
- Drainage system test
- A drainage system is tested with a water test providing at least 10 feet of head, or with an air test of 5 psi held for 15 minutes.
- Alteration compliance rule
- An alteration or extension must conform to the code as it applies to new work; the altered portion must comply even where unchanged existing work may remain.
- Repair load evaluation
- A repair that increases the load on a drain or vent must be evaluated to confirm the existing pipe sizing and venting remain adequate under the code.
- Approved materials
- Plumbing materials must be approved and listed; PVC and ABS may be used for drainage where permitted, and PEX may be used for water distribution where allowed.
- Final inspection
- A final inspection is required after the system is complete and fixtures are set; the authority having jurisdiction may reject nonconforming work and require reinspection.
- Maintenance obligation
- Fixtures, traps, and vents must remain functional; a leaking trap or an obstructed vent is a code violation that must be corrected to maintain the system.
- Cross-connection
- A cross-connection is any actual or potential connection between a potable water supply and a source of contamination, and it must be eliminated or protected against backflow.
- Backsiphonage versus backpressure
- Backsiphonage results from negative pressure in the supply, while backpressure occurs when downstream pressure exceeds supply pressure; the protection method must address the applicable type.
- Reduced pressure principle assembly
- A reduced pressure principle backflow prevention assembly (RPZ) is required for high-hazard connections such as boilers, irrigation, and chemical feed systems.
- Double check valve assembly
- A double check valve assembly may protect low-hazard connections, while a pressure vacuum breaker or atmospheric vacuum breaker serves specific low-hazard applications such as hose bibbs.
- Backflow assembly testing
- Backflow prevention assemblies must be tested at installation and annually by a certified tester, with results reported to the local water authority.
- Trap seal protection
- A maintained trap seal prevents sewer gas and pathogens from entering a building, so traps must be kept primed and vents kept open and unobstructed.
- Water heater relief piping
- A water heater must have a temperature and pressure relief valve piped to a safe discharge point, and a closed system requires thermal expansion control.
- Lead-free requirement
- Potable water systems must use lead-free materials, including lead-free solder and flux, and pipes and fittings must meet the code lead content limits.