IL Plumber study materials
IL Plumber study resources

IL Plumber key terms

IL Plumber · Get comfortable with the vocabulary.

Air gap

The unobstructed vertical distance through free atmosphere between the lowest opening of a water supply outlet and the flood-level rim of the receiving fixture or vessel. It is the strongest form of backflow prevention because no mechanical part can fail.

Related: Backflow, Flood-level rim, Cross-connection
Backflow

The unwanted reversal of water flow in a piping system, carrying nonpotable water or other substances toward the potable supply. It occurs either by backsiphonage, driven by negative pressure, or by backpressure, driven by a downstream pressure higher than supply pressure.

Related: Backsiphonage, Backpressure, Cross-connection
Backsiphonage

Backflow caused by a drop in supply pressure below atmospheric or below downstream pressure, which pulls contaminants into the potable system. Main breaks, heavy firefighting demand, or nearby high-volume use can create the vacuum that triggers it.

Related: Backflow, Vacuum breaker, Air gap
Backpressure

Backflow caused when pressure downstream of a connection exceeds the pressure in the potable supply, pushing nonpotable fluid backward. Pumps, boilers, thermal expansion, and elevated tanks are common sources of the higher downstream pressure.

Related: Backflow, Backflow preventer, Thermal expansion
Cross-connection

Any actual or potential physical link between a potable water system and a source of contamination or pollution. Even a temporarily connected hose, submerged inlet, or jumper can create one, and each must be eliminated or protected by an approved method.

Related: Backflow, Air gap, Vacuum breaker
Reduced pressure zone backflow preventer

An assembly with two independently acting check valves and a hydraulically operating differential relief valve between them. It protects against both backsiphonage and backpressure at high hazard and must be tested in place after installation and at required intervals.

Related: Backflow, Double check valve assembly, Cross-connection
Double check valve assembly

Two independently acting check valves in series, with test cocks, used to protect against backflow where the hazard is low and backpressure may occur. It is not approved for high-hazard or toxic connections and must be field tested.

Related: Reduced pressure zone backflow preventer, Backpressure, Cross-connection
Vacuum breaker

A device that admits air into a pipe to break a vacuum and stop backsiphonage. Pressure-type and atmospheric-type models serve different fixtures, and the atmospheric type must be installed at least six inches above the highest downstream outlet.

Related: Backsiphonage, Air gap, Flood-level rim
Flood-level rim

The edge of the receptacle from which water overflows, such as the top of a fixture or the top of a standpipe. It is the reference point for measuring air gaps and setting the critical level of backflow assemblies.

Related: Air gap, Critical level, Vacuum breaker
Critical level

The marked line on a backflow assembly or plumbing fixture that establishes the minimum height above which the device must be installed. It is the reference elevation that keeps the device above the flood-level rim so discharge or venting works correctly.

Related: Flood-level rim, Air gap, Reduced pressure zone backflow preventer
Potable water

Water that is safe for human consumption and meets applicable bacteriological, chemical, radiological, and physical quality standards. Plumbing must deliver it without contamination from fixtures, equipment, or nonpotable sources.

Related: Cross-connection, Nonpotable water, Backflow
Nonpotable water

Water not approved for drinking or culinary use, including reclaimed, gray, rain, and industrial water. Its piping must be identified, separated from potable lines, and protected so that no cross-connection can occur.

Related: Potable water, Cross-connection, Air gap
Thermal expansion

The increase in water volume as it is heated in a closed system, which raises pressure and can cause relief valve discharge or backflow. Control is provided by an expansion tank, a thermal expansion valve, or an approved relief arrangement.

Related: Backpressure, Water heater, Backflow preventer
Water heater temperature and pressure relief valve

A safety device that opens to discharge water when tank pressure or temperature exceeds its setpoint, preventing rupture. It must be rated for the heater, piped to a safe discharge point, and never capped or plugged.

Related: Thermal expansion, Water heater, Discharge pipe
Water heater

An appliance that heats potable water for domestic use, commonly by gas, electric, or indirect means. It requires a temperature and pressure relief valve, a drain pan where leakage could cause damage, and correct venting and combustion air for fuel-fired units.

Related: Water heater temperature and pressure relief valve, Thermal expansion, Backflow preventer
Backflow preventer

A device or assembly installed to stop reverse flow between systems. Selection depends on hazard level, whether backpressure or backsiphonage is possible, and local code requirements for testing and inspection.

Related: Reduced pressure zone backflow preventer, Double check valve assembly, Backflow
Fixture unit

A dimensionless measure of the load a plumbing fixture places on the drainage or water supply system relative to a standard fixture. Fixture units let designers size pipes from total demand rather than by simply adding fixture flows.

Related: Drainage fixture unit, Water supply fixture unit, Developed length
Drainage fixture unit

A value assigned to a fixture reflecting its probable discharge rate and waste load for sizing drainage piping. Values are tabulated by fixture type, and branch and building drain sizes are selected from total drainage fixture units.

Related: Fixture unit, Building drain, Trap arm
Water supply fixture unit

A value reflecting a fixture's probable hot and cold water demand for sizing supply piping. Because not all fixtures operate at once, total water supply fixture units are converted to probable flow for pipe sizing.

Related: Fixture unit, Developed length, Water service
Developed length

The total measured length of pipe along its run, including fittings and changes of direction, used to size pipe and select pumps. Fittings add equivalent length, so a short straight run with many elbows can behave like a much longer pipe.

Related: Water supply fixture unit, Pressure loss, Water service
Water service

The pipe and appurtenances carrying potable water from the public main or private source to the building. It includes the meter, valves, and backflow protection, and is sized for peak demand and available pressure.

Related: Water supply fixture unit, Developed length, Water main
Building drain

The lowest piping of a drainage system that receives waste from soil and waste stacks and conveys it to the building sewer. It extends to a point outside the building wall, where it becomes the building sewer.

Related: Building sewer, Drainage fixture unit, Vent stack
Building sewer

The drainage pipe carrying sewage from the building drain to the public sewer or private disposal system. It begins outside the building foundation and is sized and sloped to maintain scouring velocity.

Related: Building drain, Slope, Cleanout
Trap

A fitting that holds a water seal to prevent sewer gas from entering a building. Each fixture must have a trap unless specifically exempted, and traps must be vented and protected from siphonage and evaporation.

Related: Trap seal, Vent stack, Trap arm
Trap seal

The vertical depth of water in a trap that blocks the passage of air and gas. It must be maintained at the code-required depth, and shallower seals can be lost by evaporation, siphonage, or turbulence.

Related: Trap, Trap arm, Vent stack
Trap arm

The portion of a drainage pipe between the fixture trap and the point where the pipe connects to a stack or branch. Its length and fall are limited so that the trap is not siphoned and the trap arm remains self-cleaning.

Related: Trap, Trap seal, Fixture unit
Vent stack

A vertical pipe that provides air to a drainage system so traps keep their seals and flow is smooth. It extends through the roof or connects to an approved vent terminal and must be sized with the drainage it serves.

Related: Trap seal, Vent terminal, Building drain
Vent terminal

The open end of a vent pipe that admits air and releases gases above the building. It must be located where gases will not enter windows, doors, or air intakes and at the height required by code.

Related: Vent stack, Trap seal, Air gap
Cleanout

An access fitting that allows a drain or sewer to be cleared of blockages. It must be the same size as the pipe it serves, accessible, and provided at required locations such as changes in direction and long runs.

Related: Building drain, Building sewer, Slope
Slope

The fall of a drainage pipe per unit of horizontal run, expressed in inches per foot or as a percentage. Correct slope keeps solids moving and prevents both clogging from too little pitch and self-siphoning from too much.

Related: Building sewer, Trap arm, Cleanout
Plumbing

The practice of installing, altering, repairing, and maintaining piping, fixtures, and appurtenances that supply water and remove waste. It includes drainage, vents, water heating, and related systems that affect health and safety.

Related: Plumbing contractor, Plumber, Permit
Plumber

A person licensed under Illinois law to perform plumbing work. The license is issued by the State and may be a journeyman or master level, with different authority to supervise and contract for work.

Related: Master plumber, Journeyman plumber, Plumbing contractor
Master plumber

A plumber licensed at the highest level, authorized to design, supervise, and contract for plumbing work and to employ or supervise journeymen and apprentices. A master license is generally required to hold a plumbing contractor license.

Related: Journeyman plumber, Plumbing contractor, Apprentice plumber
Journeyman plumber

A licensed plumber qualified to perform plumbing work under the supervision of a master plumber or licensed contractor. The journeyman may not independently contract for plumbing work.

Related: Master plumber, Apprentice plumber, Plumbing contractor
Apprentice plumber

A person learning the trade under a registered apprenticeship and the supervision of a licensed plumber. Apprentices may perform plumbing work only within the terms of their apprenticeship and applicable law.

Related: Journeyman plumber, Master plumber, Plumber
Plumbing contractor

A business entity licensed to engage in the plumbing business in Illinois, operating through a licensed master plumber. The contractor is responsible for permits, code compliance, and the work performed under its license.

Related: Master plumber, Permit, Plumbing
Permit

Written authorization from the authority having jurisdiction to install, alter, or repair plumbing work. Work must not begin before the permit is issued, and inspections are required at specified stages of construction.

Related: Inspection, Authority having jurisdiction, Plumbing
Inspection

The official review of plumbing work at required stages to confirm compliance with the code and approved plans. Concealed work must be inspected before covering, and final inspection follows completion and testing.

Related: Permit, Authority having jurisdiction, Rough-in
Rough-in

The stage of plumbing installation when piping is in place but fixtures and trim are not, before walls and floors are closed. Rough-in must be inspected and tested before concealment.

Related: Inspection, Permit, Final inspection
Final inspection

The last inspection after fixtures, trim, and equipment are installed and the system is tested and operational. Approval at final inspection closes the permit and confirms the work is complete and code compliant.

Related: Inspection, Rough-in, Permit
Authority having jurisdiction

The official or agency responsible for enforcing the plumbing code and issuing permits and inspections. Its approved interpretations govern local compliance and may add requirements beyond the statewide minimum.

Related: Permit, Inspection, Illinois Plumbing Code
Illinois Plumbing Code

The statewide plumbing regulation adopted under Illinois law that sets minimum requirements for plumbing materials, design, installation, and inspection. Local governments may adopt stricter rules but may not weaken the statewide minimum.

Related: Authority having jurisdiction, Plumbing, Permit
Plumbers Licensing Code

The administrative rules implementing the Illinois Plumbing License Law, covering licensing, examinations, continuing education, and disciplinary procedures. It works together with the statute to govern who may perform plumbing work.

Related: Illinois Plumbing License Law, Plumber, Master plumber
Illinois Plumbing License Law

The Illinois statute, 225 ILCS 320, that establishes licensing requirements for plumbers and plumbing contractors and authorizes enforcement and discipline. It defines unlawful practice and the scope of regulated plumbing work.

Related: Plumbers Licensing Code, Plumber, Plumbing contractor
Unlawful practice

Performing plumbing work without the required license or outside its authorized scope. It can lead to cease-and-desist orders, fines, and discipline, and it exposes the unlicensed person and any enabling contractor to liability.

Related: Plumber, Plumbing contractor, Illinois Plumbing License Law
Continuing education

Required coursework a licensee must complete to renew a plumbing license. It keeps practitioners current on code changes, safety, and public health protection, and completion must be documented for renewal.

Related: Plumbers Licensing Code, Plumber, Illinois Plumbing License Law