Assam HS Skill Electrical Mechanics and Electrician flashcards
Assam HS Skill Electrical Mechanics and Electrician · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Ohm's law
- Current through a conductor is directly proportional to voltage and inversely proportional to resistance, expressed as V = I × R, valid for linear resistive circuits at constant temperature.
- RMS value
- The effective value of an alternating quantity that produces the same heating as an equal DC value; for a sine wave it equals peak divided by root two, about 0.707 times peak.
- Power factor
- The cosine of the phase angle between voltage and current in an AC circuit; it equals true power in watts divided by apparent power in volt-amperes.
- Kirchhoff's voltage law
- Around any closed loop of a circuit, the algebraic sum of source EMFs equals the algebraic sum of resistive and reactive voltage drops, so the net loop voltage is zero.
- Three-phase power formula
- Total active power in a balanced three-phase load equals root three times line voltage times line current times power factor, giving watts when voltage and current are RMS line values.
- Cable colour code
- In Indian wiring practice the phase is red or brown, neutral is black or blue, and protective earth is green or green-yellow, enabling safe identification at every accessory.
- Western Union joint
- A soldered joint for solid conductors made by twisting the ends, binding with a third wire, soldering and insulating; it is compact and used inside junction boxes.
- Married joint
- A high-strength soldered joint for stranded conductors where strands are fanned, interlocked, bound with a binding wire and soldered, then insulated with tape or sleeving.
- Insulation resistance test
- A DC test using a 500 V megger between live conductors and earth; a healthy low-voltage installation reads at least one megohm, while lower values indicate moisture or damage.
- Conduit fill rule
- The total cross-sectional area of conductors in a conduit should not exceed about forty percent of the conduit internal area, allowing heat dissipation and easy drawing of wires.
- Transformer EMF equation
- The RMS induced EMF in a winding equals 4.44 times frequency times turns times maximum flux, where 4.44 is the form factor of a sine wave multiplied by two pi.
- Slip of induction motor
- The difference between synchronous speed and actual rotor speed expressed as a fraction of synchronous speed; typical full-load slip for standard motors is two to five percent.
- Synchronous speed
- The speed of the rotating magnetic field, calculated as 120 times supply frequency divided by the number of poles; a four-pole motor on 50 Hz runs at 1500 rpm.
- Star-delta starter
- A starter that runs the motor in star during starting, reducing phase voltage to 57.7 percent and starting torque and line current to one-third of direct-on-line values.
- DC series motor caution
- A series motor must never be started without load because flux falls to a small value and speed rises dangerously, risking mechanical destruction of the armature.
- Back EMF
- The voltage induced in a rotating armature that opposes the supply voltage; it equals supply voltage minus armature current times armature resistance, and it limits motor current.
- PMMC instrument
- A permanent-magnet moving-coil meter whose deflection is proportional to current; it responds only to DC and has a linear scale, so rectifiers are used for AC measurement.
- Moving iron instrument
- An instrument where a soft iron vane is attracted or repelled by a coil's field; it works on AC and DC, reads RMS values, and has a non-linear scale.
- Energy meter constant
- The number of revolutions the disc makes per kilowatt-hour consumed; energy in kWh equals revolutions counted divided by this constant, used to check meter accuracy.
- Megger
- A high-resistance insulation tester that applies a DC test voltage, commonly 500 V or 1000 V, and indicates insulation resistance in megohms on a hand-cranked or electronic scale.
- Current transformer
- An instrument transformer whose primary carries the load current and whose secondary supplies a standard five-ampere signal to meters, also isolating them from high voltage.
- Earthing resistance limit
- For domestic installations earth resistance should be low, commonly one to five ohms depending on supply conditions, and is measured by the fall-of-potential method.
- MCB trip types
- Type B trips at three to five times rated current, type C at five to ten times, and type D at ten to twenty times, chosen according to load inrush current.
- RCCB
- A residual current device that compares live and neutral currents and trips when the imbalance exceeds its sensitivity, commonly thirty milliamperes for personal protection.
- Pipe earthing
- An earth electrode made of a galvanised iron pipe about 38 millimetres diameter driven vertically into moist soil, surrounded by charcoal and salt, with a watering funnel.
- Class C fire
- A fire involving energised electrical equipment; carbon dioxide or dry powder extinguishers are used, and water or foam must never be applied until the supply is isolated.
- Single-line diagram
- A drawing that represents a power system with one line per circuit, showing sources, transformers, busbars and protective devices with their ratings, omitting individual wiring.
- Bill of quantities
- A tabulated list of every item of work with description, unit of measurement, quantity and rate, forming the basis of an electrical installation estimate and tender.
- Diversity factor
- The ratio of the maximum demand of an installation to the sum of individual connected loads, used to size main switches and cables realistically rather than by total load.
- SCR
- A silicon controlled rectifier conducts from anode to cathode only after a gate pulse and remains on until anode current drops below the holding current value.
- TRIAC and DIAC
- A TRIAC conducts in both directions for AC phase control, while a DIAC is a bidirectional trigger device used to fire the TRIAC symmetrically in dimmer and fan regulator circuits.
- VFD
- A variable frequency drive converts AC to DC and back to adjustable-frequency AC, controlling induction motor speed because speed is proportional to frequency divided by poles.