- Decibel formula
- For power, dB = 10 log10(P2/P1); for voltage or current across equal impedance, dB = 20 log10(V2/V1). A 3 dB change halves or doubles power.
- dBm reference
- Absolute power relative to 1 milliwatt: dBm = 10 log10(P/1 mW). Thus 0 dBm is 1 mW, 30 dBm is 1 W, and โ30 dBm is 1 microwatt.
- Nyquist sampling theorem
- A band-limited signal with bandwidth B must be sampled at a rate of at least 2B samples per second, otherwise aliasing folds high frequencies onto low ones.
- Shannon capacity formula
- Maximum error-free rate C = B log2(1 + S/N) bit/s. Capacity grows linearly with bandwidth but only logarithmically with signal-to-noise ratio.
- Cat5e versus Cat6
- Cat5e supports 1 Gbit/s over 100 m; Cat6 supports 1 Gbit/s to 100 m and 10 Gbit/s to about 55 m, with tighter crosstalk specifications. Both are 100 ohm.
- Single-mode versus multimode fibre
- Single-mode has an 8 to 10 micrometre core and carries one mode over tens of kilometres. Multimode has a 50 or 62.5 micrometre core and suits short building or campus spans.
- OSI seven layers
- Physical, Data Link, Network, Transport, Session, Presentation, Application. The TCP/IP model collapses these into link, internet, transport and application layers.
- Circuit versus packet switching
- Circuit switching reserves a dedicated end-to-end path for the call duration. Packet switching shares links, buffers packets and suits bursty data but adds delay and jitter.
- Private IPv4 ranges
- 10.0.0.0/8, 172.16.0.0/12 and 192.168.0.0/16 are non-routable on the public Internet and require network address translation to reach external hosts.
- Subnet host count
- Usable hosts equal 2 to the power of host bits, minus two. A /24 gives 254 usable addresses, while a /30 gives 2 for point-to-point links.
- TCP three-way handshake
- The client sends SYN, the server replies SYN-ACK, and the client sends ACK. This establishes sequence numbers before data transfer begins.
- Cellular frequency reuse
- Cells form a cluster of N cells that reuse the same frequencies. The reuse ratio Q = D/R = square root of 3N; larger N means less interference but fewer channels per cell.
- Free-space path loss
- FSPL in dB = 32.44 + 20 log10(distance in km) + 20 log10(frequency in MHz). Loss rises with the square of both distance and frequency.
- GSM frame structure
- GSM uses 200 kHz carriers and TDMA frames of 4.615 ms containing eight time slots, each carrying one user burst.
- EIRP calculation
- Effective isotropic radiated power equals transmitter power in dBm plus antenna gain in dBi minus feeder loss in dB. It defines the radiated signal strength in the main beam.
- Fibre transmission windows
- 850 nm suits multimode LANs, 1310 nm gives zero dispersion in standard single-mode fibre, and 1550 nm gives the lowest attenuation, about 0.2 dB per kilometre.
- GPON rates
- Gigabit passive optical network delivers 2.488 Gbit/s downstream and 1.244 Gbit/s upstream, shared among users through passive splitters on one feeder fibre.
- Fusion versus mechanical splice
- Fusion splicing melts the fibre ends together and gives the lowest loss, typically 0.05 to 0.1 dB. Mechanical splices use an index-matching gel and show higher loss.
- OTDR function
- An optical time-domain reflectometer sends light pulses and plots backscattered power against distance, revealing splice loss, connector reflections, bends and breaks along the fibre.
- Horizontal cabling limit
- The permanent horizontal link from telecommunications room to outlet must not exceed 90 m; patch cords add up to 10 m, giving a 100 m channel.
- T568A and T568B
- These are the two standard RJ-45 pin assignments for UTP termination. A straight-through cable uses the same standard at both ends; a crossover cable uses different standards.
- Fibre bend radius rule
- Installed fibre should not be bent tighter than about ten times its cable diameter, and copper about four times, to avoid loss and mechanical damage.
- Wire-map test
- A cable tester verifies pin-to-pin continuity and reports opens, shorts, crossed pairs and split pairs, confirming the termination matches the intended standard.
- Optical link loss
- Link loss equals transmit power minus received power in dBm. It must stay within the power budget, which is transmit power minus receiver sensitivity.
- TDR fault location
- Time-domain reflectometry measures the round-trip delay of a reflection; distance equals propagation velocity times round-trip time divided by two.
- Demarcation point
- The boundary between the operator's network and the customer's premises wiring. Faults beyond it are the customer's responsibility and may attract a charge.
- Call detail record
- A record of a call or session containing calling and called numbers, start time, duration and charge. It is the evidence base for usage billing and disputes.
- Prepaid versus postpaid billing
- Prepaid deducts from a balance in real time and stops service at zero. Postpaid accumulates usage and issues a periodic invoice, requiring credit control.
- Lockout and tagout
- The safety procedure that isolates a circuit, locks the isolator and attaches a warning tag so equipment cannot be re-energised while work is in progress.
- Laser eye safety
- Never look into a fibre end or connector, even a dark one. Use an optical power meter to confirm whether light is present and label fibre links as laser sources.
- Break-even quantity
- Fixed costs divided by the difference between unit price and unit variable cost. Selling below this volume produces a loss even if each sale shows a margin.
- Active listening
- Concentrating fully on the speaker, not interrupting, and confirming understanding by restating the message. It reduces misunderstandings in fault reporting and customer handling.