Energy Management and Audit

  • Energy management hierarchy: measure and meter first, then account, then set targets, then implement; a target set without a metered baseline cannot be verified.

  • Specific energy consumption (SEC) = energy input / production output; track it on a common basis (kcal/kg, kWh/tonne, GJ/unit) and normalize for product mix, load, and ambient conditions before comparing periods.

  • Energy audit types: preliminary (walk-through, identifies focus areas), detailed (instrumented measurement, mass and energy balance, costed recommendations), and targeted (single system such as compressed air or steam).

  • Payback period = investment / annual net savings; simple payback ignores time value, so pair it with NPV or IRR for measures with life above three years.

  • Energy baseline must be adjusted with relevant variables (degree days, production volume, operating hours) using regression; an unadjusted baseline overstates or understates savings.

  • Instrumentation essentials: power analyzer for kW, kWh, PF and harmonics; ultrasonic flow meter for closed pipes; flue gas analyzer for O2, CO, CO2 and stack temperature; lux meter; thermal imager.

  • Measurement uncertainty rule: instrument accuracy plus installation error; clamp-on CT readings below 20% of range and low-flow ultrasonic readings are common sources of large error.

  • Energy cost breakdown by utility: electricity demand charge (kW) plus energy charge (kWh) plus power factor penalty; fuel cost plus steam/hot water cost per tonne; allocate to cost centres for accountability.

  • ISO 50001 structure: energy policy, energy review and baseline, EnPIs and EnBs, objectives and action plans, operational control, monitoring and measurement, management review.

Quick reference

Energy Efficiency in Thermal Utilities

  • Boiler efficiency by indirect (loss) method: efficiency = 100 - (dry flue gas loss + loss from H2 in fuel + moisture in fuel + moisture in air + unaccounted + radiation/convection); each loss is a percentage of heat input.

  • Dry flue gas loss rises roughly 1% per 22 °C rise in stack temperature for typical natural gas firing; every 15-20 °C reduction in stack temperature raises efficiency about 1%.

  • Optimum excess air: too little gives CO and smoke, too much raises dry flue gas loss; target 3-5% O2 (about 15-20% excess air) for gas, 4-6% O2 for oil, higher for coal.

  • Steam trap types: thermostatic (subcooled condensate), thermodynamic (flash steam), mechanical float-and-thermostatic (condensate level); failed-open traps waste live steam, failed-closed cause water hammer.

  • Blowdown: dissolved solids concentrate in the boiler; blowdown rate % = (feedwater TDS / (maximum permissible boiler water TDS - feedwater TDS)) x 100; heat recovery from blowdown via flash vessel or heat exchanger.

  • Furnace and kiln: heat balance = heat in (fuel + preheated air + charge) minus heat out (charge, flue gas, wall losses, openings, cooling water, stored heat); wall heat loss = surface area x U x temperature difference.

  • Waste heat recovery options ranked by temperature: recuperator and regenerator for high-temperature flue gas, economizer for boiler feedwater, air preheater for combustion air, heat pump for low-grade below 100 °C.

  • Steam distribution: pressure drop and velocity limits (typically 25-40 m/s for saturated steam), insulation to limit surface temperature to 50-60 °C, and condensate recovery to reduce make-up and chemical treatment cost.

  • Refrigeration COP = refrigeration effect / work input; for a vapour compression cycle the theoretical COP falls as condenser temperature rises and as evaporator temperature falls.

Quick reference

Energy Efficiency in Electrical Utilities

  • Motor input power = √3 x V x I x power factor; shaft power = input power x motor efficiency; loading = shaft power / rated output, and efficiency peaks near 75-90% load.

  • Motor replacement rule: replace when annual energy saving x tariff x remaining life exceeds the premium for a high-efficiency unit; rewinding a small motor more than once is often uneconomic.

  • Fan and pump affinity laws: flow varies with speed, head with speed squared, power with speed cubed; a 20% speed reduction cuts power by about 50%, so variable speed drives beat throttling.

  • Pump system: operating point is where the pump curve meets the system curve; static head plus friction; throttling and bypass control waste energy, VSD or impeller trimming are preferred.

  • Compressed air: specific power (kW per m3/min) rises with discharge pressure; rule of thumb is about 7-8% power per 1 bar; every 1 bar reduction in pressure saves roughly 7% of compressor energy; leaks of 1 mm hole at 7 bar waste about 0.3-0.5 kW.

  • Compressed air pressure drop budget: 0.3 bar across dryer and filters, 0.3 bar in piping, 0.3 bar at point of use; total should stay under 0.5-1.0 bar.

  • Lighting efficacy (lm/W): LED 100-150, fluorescent 60-90, mercury vapour 40-60, high-pressure sodium 80-120; use lux level targets per application and daylight-linked or occupancy controls.

  • Transformer losses: no-load (core) loss is constant, load loss varies with square of load current; optimum loading for maximum efficiency occurs where core loss equals copper loss, typically 50-70% of rating.

  • Power factor correction: kVAr required = kW x (tan φ1 - tan φ2); capacitors near the load reduce line current, line losses (I squared R) and demand charges; avoid leading PF at light load.

Quick reference

Energy Performance Assessment and Energy Conservation Act

  • Energy Conservation Act 2001 (India) established BEE; amended in 2010 and 2022, the 2022 amendment widened scope to large residential buildings and adds carbon credit trading through the compliance mechanism.

  • Designated consumers: energy-intensive sectors (aluminium, cement, fertilizer, iron and steel, pulp and paper, chlor-alkali, sugar, textiles, thermal power, petroleum refining, railways, petrochemicals, DISCOMs) notified with annual energy consumption thresholds.

  • Perform, Achieve and Trade (PAT): each designated consumer gets a specific energy consumption target; excess savings become tradable energy saving certificates (ESCerts), shortfalls must be met by purchase or penalty.

  • Energy Manager and Energy Auditor certification by BEE: Energy Manager examination for designated consumers, certified energy auditor accreditation, with periodic re-certification.

  • Energy performance assessment sequence: define boundary, collect nameplate and operating data, measure with calibrated instruments, compute SEC, compare with benchmark or design value, quantify savings and cost.

  • Uncertainty and validity: readings must be taken at steady state, over representative periods; use at least three readings and report mean plus instrument accuracy; energy savings reported as difference of adjusted baselines.

  • Benchmarking sources: BEE sector-specific SEC benchmarks, PAT targets, and internal best-ever month; compare on like-for-like product and capacity utilization.

  • Standards and labelling under the Act: star rating for appliances, mandatory for notified products, with label period and revision cycles; BEE star rating is based on energy efficiency ratio or specific energy consumption thresholds.

  • Carbon and reporting: ESCerts trade on power exchanges; the 2022 amendment's carbon credit trading scheme links PAT savings to verified emission reductions, so measurement and verification records must be auditable.

Quick reference

Energy Efficiency in Buildings

  • Envelope heat gain: conduction through walls and roof = U x A x ΔT; glazing solar gain = SHGC x area x solar irradiance; shading coefficient and SHGC are the key glazing parameters.

  • Overall Thermal Transfer Value (OTTV) for walls and Roof Thermal Transfer Value (RTTV) for roofs; ECBC sets maximum OTTV/RTTV limits by climate zone (hot-dry, warm-humid, composite, temperate, cold).

  • ECBC applies to commercial buildings with connected load of 100 kW or more (or contract demand of 120 kVA and above); it covers envelope, lighting, HVAC, service hot water and electrical systems.

  • HVAC energy: chiller efficiency in kW/TR or COP; 1 TR = 3.517 kW; system efficiency includes chiller, pumps, cooling tower and air distribution, so measure kW/TR at the system level.

  • Chilled water parameters: 5-7 °C supply and 12-13 °C return, 4-6 °C differential; flow = TR x 3.517 / (4.187 x ΔT) in kg/s; low ΔT syndrome indicates coil or balancing problems.

  • Ventilation and indoor air quality: fresh air per ASHRAE 62.1 or NBC; heat recovery wheel or run-around coil recovers 50-70% of exhaust energy in high fresh-air buildings.

  • Lighting power density (W/m2) limits by building type and climate; daylight factor, occupancy sensors, and daylight-linked dimming cut lighting energy 20-40% in perimeter zones.

  • Building energy simulation tools (EnergyPlus, eQUEST, IES-VE) estimate annual consumption; calibrate against 12 months of utility bills within about 10% before using for design decisions.

  • Energy performance index (EPI) = annual energy use (kWh) / carpet area (m2); compare with benchmarks for the building category; GRIHA and IGBC ratings reward measured performance and commissioning.

Quick reference

Standards & Labelling and Demand Side Management

  • BEE star label: stars from 1 to 5 based on defined efficiency thresholds for each product; mandatory products include air conditioners, refrigerators, distribution transformers, fans, motors, and LED lamps under notified schedules.

  • Label metrics differ by product: EER or ISEER for room ACs, kWh/year or star for refrigerators, lm/W for lamps, total loss and efficiency for distribution transformers, service value for ceiling fans.

  • Standards revision: BEE raises thresholds periodically, so a given model's star rating can change without any change to the product; check the label validity period.

  • Demand Side Management: load shifting (moving load from peak to off-peak), peak clipping (reducing peak demand), valley filling (building off-peak load), strategic conservation and strategic load growth.

  • Time-of-day tariff: peak, off-peak and normal slabs; DSM economics compare the tariff differential with the cost of storage or load shifting; ToU is the main price signal for industrial consumers.

  • Demand response: consumer reduces or shifts load on utility signal; agricultural feeder separation and solar pumps reduce subsidized peak demand; smart meters enable automated DR.

  • Load management tools: maximum demand controller, automatic power factor correction, staggered starting of large motors, captive generation during peak, and thermal storage for cooling.

  • Energy efficiency vs DSM distinction: efficiency reduces total kWh permanently, DSM changes the timing or shape of the load profile; both are needed for resource adequacy.

  • Measurement and verification of DSM programs uses deemed savings, metered baseline, or billing analysis; free-ridership and rebound effect reduce realized savings below gross estimates.