Mistake 1

Computing boiler or furnace efficiency on an HHV (gross calorific value) basis while quoting benchmark figures that are defined on an LHV (net calorific value) basis, then declaring the equipment deficient.

Indian fuels are usually priced and analysed on GCV, but efficiency benchmarks in most reference material are on NCV; the two differ by roughly 5-10 percent depending on hydrogen and moisture content, so a correct measurement looks like a failure.

What to do instead

Before comparing, write the basis (GCV or NCV) next to every efficiency number and convert using the fuel's hydrogen and moisture content. Practise converting indirect-method efficiency between the two bases until the direction of the correction is automatic.

Mistake 2

Reading stack losses from an indirect heat-balance audit but omitting unaccounted losses, then presenting a heat balance whose components sum to 85 percent without explanation.

Candidates treat the indirect method as a pure subtraction exercise and forget that unaccounted losses (radiation, convection, moisture in air, carbon monoxide) are a legitimate line item that must be estimated or at least declared.

What to do instead

Always close the balance explicitly: show the measured losses, list the unaccounted remainder, and state whether it is plausible for the equipment type. If it exceeds about 5 percent, recheck flue gas temperature, excess air and reference temperature assumptions.

Mistake 3

Sizing a pump or fan retrofit by comparing nameplate flow and head against the duty point instead of measuring actual operating flow and power, leading to overstated savings.

The affinity laws are easy to apply and tempting to use on rated data, but real systems run far from rated duty; without measured flow, head and input power, the cube-law saving is calculated on a curve the equipment never sees.

What to do instead

Insist on field measurement of flow, head and motor input power at the actual operating point before applying affinity laws. State the measurement method (ultrasonic flow, pitot traverse, power analyser) and reconcile measured power against the efficiency chain.

Mistake 4

Calculating motor energy savings from load factor alone while ignoring the motor's part-load efficiency curve, so that a lightly loaded oversized motor is credited with savings it cannot deliver.

Candidates use a single rated efficiency figure and linear scaling; in reality efficiency falls steeply below about 50 percent load, and the correct saving from right-sizing depends on where both the old and new motors sit on their curves.

What to do instead

For every motor measure or estimate actual load (input power versus rated), read efficiency at that load, and compute savings as the difference in input power at the same shaft output. Flag motors below 50 percent loading as right-sizing candidates rather than assuming proportional savings.

Mistake 5

Treating the specific energy consumption (kWh per unit of product) as the whole energy performance assessment and ignoring the influence of production volume, product mix and capacity utilisation.

SEC is the most familiar metric and easy to compute, but it moves with throughput; a plant running at 40 percent capacity shows a worse SEC without any efficiency change, and candidates then report a phantom deterioration or improvement.

What to do instead

Normalise before concluding: plot SEC against production, separate fixed and variable energy, and compare at matched load. Use energy per unit at a reference capacity or a regression-based baseline rather than a raw annual ratio.

Mistake 6

Confusing designated consumers' obligations under the Energy Conservation Act with the compliance mechanisms of the PAT scheme, for example stating that exceeding a target automatically attracts a penalty rather than tradable certificates.

The Act, the PAT rules and state-level requirements overlap, and candidates memorise fragments without mapping which instrument creates which obligation, who verifies, and what happens on over- or under-achievement.

What to do instead

Build a one-page map: Act section or rule, implementing agency, who is covered, what must be submitted, who accredits and verifies, and the consequence of excess or shortfall in energy savings. Rehearse the difference between ESCerts and penalties until it is unambiguous.

Mistake 7

Calculating the overall thermal transmittance (U-value) of a composite wall by simple arithmetic averaging of layer U-values instead of summing thermal resistances.

U-values are often quoted per material, and averaging them is arithmetically simple; the correct method requires resistances to be added, including surface films, so averaging overstates heat gain and distorts the load estimate.

What to do instead

Always convert each layer to resistance (thickness divided by conductivity), add surface film resistances, then invert. Work two or three worked examples with insulation added to confirm the direction and magnitude of the change.

Mistake 8

Reporting a cooling load or building energy index without stating the weather or degree-day basis, then comparing it directly with a benchmark from a different climate zone.

Benchmarks are frequently quoted as national averages; without normalisation, a building in a hot-dry region looks inefficient against a composite-climate figure, and candidates attribute the gap to envelope or system performance.

What to do instead

Normalise to degree-days or a stated reference year before benchmarking, and always write the climate basis beside the index. Where normalisation is impossible, compare only within the same climate zone and say so.

Mistake 9

Reading a star rating as a direct statement of energy consumption, rather than as a band derived from a specific test standard and label parameter for that product category.

The label is designed for consumer comparison, and candidates transfer the star logic across appliance types where the reference values, test conditions and even the direction of the scale differ.

What to do instead

Learn, per product category, what the label parameter is, which test standard defines it, and what the star boundaries are. When a question gives a consumption figure, convert it to the label parameter before assigning stars.

Mistake 10

Estimating demand-side management savings by summing connected load of shifted or curtailed equipment instead of integrating the actual load profile over time.

Connected load is a single number and feels like the saving, but DSM value comes from the shape of the curve; diversity, duty cycles and rebound after the event mean the energy and demand reductions differ substantially from the nameplate sum.

What to do instead

Work from a measured 15-minute or hourly load profile, integrate before and after the intervention, and separate demand reduction (kW) from energy reduction (kWh). Check for payback load after the curtailment window before claiming the saving.