- Confined space oxygen limit
- Before entering a manhole or septic tank, test the atmosphere; oxygen below 19.5 percent by volume means entry is prohibited and forced ventilation plus a permit is required.
- Trench shoring depth
- Excavated trench sides deeper than about 1.5 metres must be shored, and excavated soil is stacked at least 0.6 metres away from the trench edge.
- Class C fire extinguisher
- Fires involving flammable gases are Class C and are extinguished with dry powder; electrical fires are fought with carbon dioxide, never with water or foam.
- Pipe wrench jaw direction
- The jaw teeth of a pipe wrench must face the direction of rotation so that the pull is taken toward the handle, giving a firm grip without slipping.
- Hacksaw blade pitch
- An 18 teeth per inch blade suits thick metal and pipe, 24 is general purpose, and 32 suits thin-walled tube and sheet where at least three teeth contact the work.
- Pipe cutter operation
- A pipe cutter scores and severs metal pipe; tighten the adjusting knob about a quarter turn per revolution, apply cutting oil, and ream the burr afterwards.
- CPVC pipe use
- Chlorinated polyvinyl chloride pipe carries hot water up to about 90 degrees Celsius and is joined with solvent cement, unlike UPVC which is mainly for cold water and drainage.
- Galvanised iron pipe
- Mild steel pipe coated with zinc by hot-dip galvanising, used for cold water supply and joined by threaded sockets and fittings; the zinc coating resists corrosion.
- Check valve function
- A check valve allows flow in one direction only and prevents backflow; a gate valve isolates flow, a globe valve throttles, and a ball valve gives quarter-turn isolation.
- Nominal bore meaning
- Nominal bore is the approximate internal diameter used to designate pipe size; a 25 mm nominal bore pipe has an outside diameter of about 33.4 mm.
- Eccentric reducer placement
- An eccentric reducer is offset to one side and is fitted in horizontal runs with the flat side up so that air pockets and condensate traps are avoided.
- Union versus coupling
- A union has three parts and allows a line to be disconnected without cutting, while a coupling is a simple sleeve joining two pipes of the same size.
- File cut types
- A single cut file has parallel teeth for finishing and sharpening, while a double cut file has crossing teeth for rapid metal removal; a bastard file is coarser than second cut.
- Spanner selection rule
- The spanner must fit the nut flats fully; use an open-end spanner for two-point access, a ring spanner for full grip, and pull toward the fixed jaw.
- Fitting take-out
- Take-out is the distance a pipe inserts into a fitting; cut length equals centre-to-centre length minus the sum of the take-outs at both ends.
- Long radius elbow take-out
- For a 90 degree long radius elbow, the take-out equals 1.5 times the nominal pipe diameter; for a short radius elbow it equals 1.0 times the nominal diameter.
- PTFE tape winding direction
- PTFE tape is wound clockwise around the male thread in the direction of tightening, about three turns, leaving the first thread bare so the joint starts cleanly.
- Solvent cement joint cure
- For a PVC solvent cement joint, clean and prime both surfaces, apply cement, insert with a quarter turn, hold about 30 seconds, and cure fully before pressure testing.
- Compression joint tightening
- Slide the nut and olive onto the tube, insert the tube fully, and tighten the nut hand tight plus about one and a quarter turns with a spanner without overtightening the olive.
- Overhead tank minimum head
- The overhead tank must give a minimum head of about 2 to 3 metres above the highest fixture so that adequate pressure reaches the top floor.
- Fixture unit method
- Each fixture is assigned loading units, about 3 for a water closet and about 1 for a wash basin, and the total selects the supply pipe size from a sizing table.
- Water supply hydrostatic test
- A new supply line is tested at about 1.5 times working pressure, with a minimum of 10 bar, for at least one hour with no drop on the gauge.
- Wash basin rim height
- A wash basin rim is fixed about 780 to 800 millimetres above finished floor level, with a 32 or 40 millimetre waste outlet and an accessible basin trap.
- Floor trap water seal
- A floor or gully trap retains a water seal of at least 50 millimetres to stop sewer gas entering the building and is placed at the lowest point of a wet floor.
- Soil pipe versus waste pipe
- A soil pipe carries human waste from water closets, while a waste pipe carries sullage from sinks and basins; a vent pipe equalises pressure in the system.
- Self-cleansing velocity
- Self-cleansing velocity is the minimum flow speed that keeps solids moving in a drain, about 0.6 metres per second, while the maximum permissible is about 3 metres per second.
- Drainage gradient for 100 mm pipe
- A 100 millimetre soil pipe is laid at a fall of about 1 in 60 to 1 in 80, while a 150 millimetre sewer uses about 1 in 100 to 1 in 150.
- Dripping tap diagnosis
- Water dripping from the spout means a worn washer or ceramic cartridge, while leakage at the spindle means worn gland packing or a perished O-ring.
- WC overflow diagnosis
- Water overflowing into the pan means the float valve is not shutting off, caused by a worn washer, a punctured float, or a misadjusted float arm.
- Job card purpose
- A job card records the work done at a site, while a material requisition requests stores, an invoice bills the customer, and a measurement sheet records quantities for payment.
- Plumbing quotation contents
- A quotation states the scope of work, material brand and grade, quantity, rate, total amount, time schedule, payment terms, and the validity period of the offer.