- Modular brick size
- Standard modular brick per IS 1077 measures 190 × 90 × 90 mm; with a 10 mm mortar joint the nominal size becomes 200 × 100 × 100 mm, giving 500 bricks per cubic metre of masonry.
- Bulking of sand
- Increase in loose volume of sand due to moisture films around particles, typically 20–30% at 4–6% moisture content; must be accounted for when measuring sand by volume for mortar.
- Slump test
- Workability test using a cone 100 mm top, 200 mm bottom, 300 mm high; concrete is filled in three layers, rodded 25 times each, and the settlement measured in millimetres.
- Initial setting time of cement
- Minimum 30 minutes for ordinary Portland cement when tested by Vicat apparatus; mortar must be placed and compacted before this time to avoid loss of strength.
- English bond
- Brick bond with alternate courses of headers and stretchers; strongest bond for walls one brick or thicker, with queen closers next to quoin headers to break vertical joints.
- Queen closer
- A brick cut lengthwise into two halves; placed next to the quoin header in English and Flemish bond to adjust bond and prevent continuous vertical joints at corners.
- Cavity wall
- Two leaves of masonry 90–100 mm thick separated by a 50–75 mm air gap; galvanised steel wall ties at 900 mm horizontal and 450 mm vertical spacing tie the leaves together.
- Through stone
- A stone extending the full thickness of a rubble masonry wall, placed at 1.5 m intervals both longitudinally and transversely to tie the wall faces and distribute load.
- Plaster thickness for brick walls
- 12 mm for internal brick walls, 15–20 mm for external walls, and 6 mm for ceilings; two-coat work uses a 10 mm undercoat plus a 6 mm finish coat.
- Plaster of Paris setting time
- Plaster of Paris sets in 5–15 minutes after mixing with water; used for decorative cornices and mouldings but unsuitable for damp locations because it softens with moisture.
- Punning or three-coat plaster
- High-quality plaster finish made of a 12 mm backing coat, 6 mm floating coat, and 3 mm finishing coat of lime or gypsum; used for smooth internal surfaces in quality work.
- Trap seal depth
- Depth of water in a trap that prevents sewer gas entry; minimum 50 mm for water closets and floor traps, and 75 mm for gully traps in drainage systems.
- One-pipe drainage system
- System in which soil and waste pipes discharge into a single vertical stack, with a separate vent pipe to equalise pressure and prevent trap seal loss.
- Self-cleansing velocity
- Minimum flow velocity of 0.75 m per second in horizontal drains that keeps solid matter moving and prevents silt deposition; achieved by gradients of 1 in 40 to 1 in 80.
- Inspection chamber spacing
- Inspection chambers are provided at intervals not exceeding 30 m on straight drain runs, and at every change of direction, junction, or change of gradient.
- RCCB tripping current
- Residual current circuit breaker for human protection trips at 30 mA earth leakage; for fire protection the setting is 100 mA; the test button should be pressed monthly.
- Earthing resistance limit
- Earth electrode resistance should not exceed 1 ohm for a single electrode in ordinary soil; measured with an earth tester and kept low by charcoal and salt backfill.
- Lighting circuit load limit
- A single lighting circuit should carry not more than 800 watts or 10 points; power circuits are kept separate, and the main switch and meter are sized from total connected load.
- Mortise and tenon joint
- Joint in which a projecting tenon on one member fits into a mortise cut in the other; used in door frames and furniture because it resists tension and bending well.
- Standard residential door size
- Per IS 10021, a residential door is commonly 900 × 2000 mm or 800 × 2000 mm, with a leaf thickness of 35–40 mm; bathroom doors are typically 700 × 2000 mm.
- Holdfast
- A mild steel flat about 300 mm long, fixed to the door or window frame and embedded in masonry at top and bottom on each side to anchor the frame.
- Emulsion paint coverage
- One litre of emulsion paint covers about 8–10 square metres per coat; enamel covers 10–12 square metres; primer covers 10–12 square metres; recoat after 4–6 hours.
- French polish
- Shellac dissolved in methylated spirit, applied with a rubber pad in circular motion; gives a high-gloss transparent finish on internal wooden furniture.
- Paint blistering
- Formation of raised bubbles under a paint film caused by moisture trapped beneath the surface; cured by removing the film, drying the substrate, and repainting.
- Epoxy injection for cracks
- Repair method for fine cracks in concrete: ports drilled at 200–300 mm spacing, surface sealed, low-viscosity epoxy injected at low pressure, then cured for 24 hours.
- Concrete spalling repair
- Chip back to sound concrete, clean reinforcement, apply rust converter and bonding agent, then fill with polymer-modified mortar and cure to restore section and protection.
- Column jacketing
- Retrofitting technique in which a column is enlarged with 75–100 mm of new concrete and reinforcement, tied to the original section by shear keys and dowels.
- Steel bar weight formula
- Weight of a steel bar in kilograms per metre equals the square of its diameter in millimetres divided by 162; a 12 mm bar therefore weighs 0.888 kg per metre.
- Dry volume factor for concrete
- Wet concrete volume is multiplied by 1.54 to obtain dry volume of ingredients; cement bags equal dry volume times cement ratio divided by sum of ratios and by 0.035.
- Centre line method
- Estimation method suitable for walls of equal thickness: total centre line length multiplied by width and depth, with deductions at junctions to avoid double counting.
- Personal protective equipment on site
- Helmet, safety shoes, gloves, goggles, ear plugs, dust mask, and full-body harness for work above 1.8 m; all must be inspected before use and replaced when damaged.
- Leaning ladder slope rule
- A leaning ladder should be set at a 4:1 slope, extend at least 1 m above the landing, be secured at top and bottom, and never be worked from the top three rungs.