Karnataka SSLC Elements of Electrical Engineering IV - JTS (KSEAB) flashcards
Karnataka SSLC Elements of Electrical Engineering IV - JTS (KSEAB) · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Ohm's law
- For a metallic conductor at constant temperature, current is directly proportional to applied voltage: V = IR, where R is resistance in ohms.
- Specific resistance
- Resistivity ρ is the resistance of a unit cube of material: R = ρL/A. Copper has very low ρ, so it makes efficient conductors.
- Kirchhoff's current law
- At any junction, the algebraic sum of currents entering and leaving is zero, because charge cannot accumulate at a node.
- Electrical energy unit
- One kilowatt-hour is the energy used by a 1000 W load running for one hour, equal to 3.6 million joules.
- Magnetic flux density
- B = Φ/A measured in tesla, where Φ is flux in weber and A is the cross-sectional area in square metres perpendicular to the flux.
- Magnetic Ohm's law
- Flux equals magnetomotive force divided by reluctance: Φ = NI/S, the magnetic analogue of V = IR in electric circuits.
- Faraday's law of induction
- The emf induced in a coil equals the negative rate of change of flux linkage: e = −N dΦ/dt, with the sign given by Lenz's law.
- Fleming's left-hand rule
- With thumb, forefinger and middle finger mutually perpendicular, they give force, flux density and current direction for a conductor in a magnetic field.
- Inductor stored energy
- A coil of inductance L carrying current I stores magnetic energy equal to half L times I squared, released when current falls.
- RMS value
- For a sine wave the root-mean-square value is peak divided by root two, about 0.707 of peak; it equals the equivalent DC heating value.
- Capacitive reactance
- X_C = 1/(2πfC), measured in ohms; it falls as frequency or capacitance rises, so a capacitor blocks DC and passes AC.
- Power factor
- Cosine of the angle between voltage and current; it equals R/Z in a series circuit and determines real power P = VI cos φ.
- Series resonance
- When X_L equals X_C in a series RLC circuit, impedance is minimum and equals R, current is maximum, at f = 1/(2π√(LC)).
- Star and delta relation
- In star, line voltage is root three times phase voltage and line current equals phase current; in delta, line current is root three times phase current.
- Three-phase power
- Balanced load power equals root three times line voltage times line current times power factor, whether the load is star or delta connected.
- Transformer emf equation
- E = 4.44 f N Φm gives the rms induced emf, where f is frequency, N turns and Φm the maximum core flux in weber.
- Transformer efficiency maximum
- Efficiency peaks when copper loss equals core loss; core loss stays constant while copper loss varies with the square of load current.
- DC motor back emf
- The rotating armature induces a back emf E_b = V − I_aR_a that opposes supply voltage and controls armature current and motor speed.
- Synchronous speed
- N_s = 120f/P revolutions per minute, where f is supply frequency and P the number of poles; an induction motor runs slightly slower.
- Slip
- Slip s = (N_s − N)/N_s expresses how far rotor speed falls below synchronous speed; rotor frequency equals slip times supply frequency.
- DC series motor caution
- A series motor must never be started without load, because its flux is set by armature current and speed would rise dangerously.
- Two-way switch
- A two-way switch has one common terminal and two strappers, allowing a lamp to be controlled from either of two positions.
- RCCB function
- A residual current device compares phase and neutral current and trips when the difference, an earth leakage, exceeds its rated sensitivity.
- Earthing purpose
- Earthing connects exposed metalwork to the general mass of earth, giving a low-resistance path so protective devices operate and touch voltage stays safe.
- Fuse selection
- The fuse rating is chosen above the normal load current but below the current-carrying capacity of the cable it protects.
- PMMC instrument
- A permanent-magnet moving-coil meter deflects with torque proportional to current, reads average value, and needs a rectifier for alternating current.
- Energy meter constant
- Meter constant is the number of disc revolutions per kilowatt-hour; energy consumed equals revolutions counted divided by that constant.
- Two-part tariff
- A tariff with a fixed charge based on connected load or maximum demand plus a running charge for each unit of energy consumed.
- Moving-iron instrument
- An instrument where a soft-iron vane is attracted or repelled by a coil's field; it reads RMS values and works on both AC and DC.
- Electric shock first aid
- Switch off the supply first, separate the victim using dry insulating material, and begin artificial respiration if breathing has stopped.
- Lux and lumen
- Lumen measures luminous flux emitted; lux is illuminance, one lumen falling on one square metre of surface.
- Star-delta starter
- A starter that runs the motor in star during acceleration, reducing phase voltage and starting current to one third, then switches to delta.