Photoelectric effect

Process in which an incoming X-ray photon transfers all its energy to an inner-shell electron, ejecting it and producing a photoelectron. It dominates at low kVp and in high-atomic-number tissues such as bone, and creates most subject contrast.

Related: Compton scatter, Half-value layer, Beam attenuation
Compton scatter

Interaction where a photon strikes an outer-shell electron, gives up part of its energy, and is deflected in a new direction. Scattered photons add fog to the image and dose to staff, so it is reduced by collimation and grids.

Related: Photoelectric effect, Grid ratio, Beam attenuation
Beam attenuation

Reduction in intensity of an X-ray beam as it passes through matter, caused by absorption and scattering. It increases with tissue thickness, tissue density, atomic number, and lower photon energy.

Related: Half-value layer, Compton scatter
Half-value layer

Thickness of a specified absorber, usually aluminium, that reduces beam intensity to half its original value. It measures beam quality or penetrating power and is checked during routine equipment quality control.

Related: Beam attenuation, Kilovoltage peak, Quality assurance
Kilovoltage peak

Maximum voltage applied across the X-ray tube during exposure, expressed in kVp. It sets photon energy and penetrating power; raising kVp shortens the scale of contrast and reduces patient skin dose for a given receptor exposure.

Related: Milliampere-seconds, Contrast scale, Half-value layer
Milliampere-seconds

Product of tube current in milliamperes and exposure time in seconds, giving total charge and therefore the number of X-ray photons produced. It controls receptor exposure and image density rather than beam penetration.

Related: Kilovoltage peak, Exposure indicator
Anode heel effect

Uneven beam intensity across the X-ray field because photons produced deeper in the angled anode target are absorbed by the target itself. Intensity is lower on the anode side, so thicker patient parts are usually placed toward the cathode.

Related: Focal spot, Collimation
Focal spot

Small area on the anode target where X-rays are generated. A smaller focal spot gives sharper images but limits tube current, so large focal spots are used where heat loading is high.

Related: Anode heel effect, Geometric unsharpness, Source-to-image distance
Source-to-image distance

Distance from the X-ray tube focal spot to the image receptor. It affects magnification, geometric unsharpness, and receptor exposure, since intensity falls with the square of distance.

Related: Geometric unsharpness, Object-to-image distance, Inverse square law
Object-to-image distance

Distance between the anatomical part being examined and the image receptor. Keeping it small reduces magnification and blur, so the part is placed as close to the receptor as the position allows.

Related: Source-to-image distance, Geometric unsharpness, Magnification
Geometric unsharpness

Blurring of structure edges caused by the finite size of the focal spot and by the distances involved. It is reduced by a small focal spot, a long source-to-image distance, and a short object-to-image distance.

Related: Focal spot, Object-to-image distance, Magnification
Magnification

Enlargement of the projected image compared with the true object size, produced by divergence of the beam. It increases as the object moves away from the receptor and is calculated as the ratio of source-to-image to source-to-object distance.

Related: Object-to-image distance, Geometric unsharpness
Inverse square law

Statement that radiation intensity from a point source is inversely proportional to the square of the distance from it. Doubling the distance reduces intensity to one quarter, which underpins distance protection and exposure calculations.

Related: Source-to-image distance, Radiation protection survey
Radiographic projection

Path of the central ray through the patient onto the receptor, described by the entrance and exit points. Naming the projection precisely prevents wrong-side and wrong-view repeats in clinical practice.

Related: Central ray, Positioning landmark
Central ray

Central axis of the X-ray beam, aimed at a specific anatomical point for each projection. Correct alignment of the central ray with the part and receptor controls distortion and ensures reproducible positioning.

Related: Radiographic projection, Positioning landmark
Positioning landmark

Palpable surface point, such as the iliac crest, xiphoid process, or jugular notch, used to align the central ray and receptor. Reliable landmarks allow consistent positioning when body habitus varies.

Related: Central ray, Radiographic projection
Contrast scale

Range of grey levels recorded on an image, from short scale with high contrast to long scale with low contrast. It is mainly influenced by kilovoltage and by the type of image receptor used.

Related: Kilovoltage peak, Window width
Exposure indicator

Numeric value reported by a digital system that estimates receptor exposure. It guides correction of technique but is not a direct patient dose measurement and varies between manufacturers.

Related: Milliampere-seconds, Window level
Window width

Digital display control that sets the range of pixel values mapped to visible grey levels. A wide window shows more soft-tissue shades, while a narrow window increases displayed contrast.

Related: Window level, Contrast scale
Window level

Digital display control that sets the central pixel value around which grey levels are distributed. Adjusting it brightens or darkens the displayed image without changing the stored data.

Related: Window width, Image post-processing
Image post-processing

Computer-based alteration of stored digital image data after acquisition, including edge enhancement, smoothing, and grey-scale changes. It improves visibility but cannot recover information never captured.

Related: Window level, Exposure indicator
Grid ratio

Ratio of the height of lead strips in an anti-scatter grid to the distance between them. Higher ratios remove more scatter but demand more precise alignment and higher exposure factors.

Related: Compton scatter, Collimation
Collimation

Restriction of the X-ray beam to the area of clinical interest using adjustable shutters. It reduces patient dose, scatter, and fog, and the light field must match the exposed area.

Related: Grid ratio, Anode heel effect
Quality assurance

Planned programme of checks and maintenance that keeps radiographic equipment and processing within accepted performance limits. It includes tests of output, kilovoltage accuracy, beam alignment, and image quality.

Related: Half-value layer, Sensitometry
Sensitometry

Measurement of a film's response to graded exposures, producing a characteristic curve of density against log exposure. It monitors developer activity, film speed, and contrast in darkroom quality control.

Related: Quality assurance, Film density
Film density

Degree of blackening of a processed radiograph, measured as optical density on a logarithmic scale. Adequate density is needed to see detail, and it depends on exposure and processing conditions.

Related: Sensitometry, Safe light
Safe light

Darkroom lamp fitted with a filter that emits light to which the film is least sensitive. It allows handling of film during processing, and its distance, wattage, and filter must be checked to avoid fog.

Related: Film density, Quality assurance
Effective dose

Tissue-weighted sum of equivalent doses across the body, expressed in sieverts, reflecting overall radiation risk. It allows comparison of different examinations and procedures with natural background exposure.

Related: Absorbed dose, ALARA principle
Absorbed dose

Energy deposited by ionising radiation per unit mass of material, measured in gray. It describes physical energy transfer and is the basis for calculating equivalent and effective dose.

Related: Effective dose, Thermoluminescent dosimeter
ALARA principle

Practice of keeping radiation doses as low as reasonably achievable, taking economic and social factors into account. It is applied through collimation, shielding, distance, and good technique.

Related: Collimation, Effective dose, Lead apron
Thermoluminescent dosimeter

Personal monitoring badge containing lithium fluoride crystals that store energy from radiation and release light when heated. It records cumulative dose over a wearing period and must be worn correctly.

Related: Absorbed dose, Radiation protection survey
Lead apron

Protective garment with lead or lead-equivalent material worn by staff and carers during exposures. It attenuates scattered radiation, and its integrity should be checked radiographically for cracks.

Related: ALARA principle, Radiation protection survey
Radiation protection survey

Structured measurement of radiation levels in and around an X-ray facility to confirm shielding and safe working practice. Results are documented and compared with regulatory dose limits.

Related: Thermoluminescent dosimeter, Inverse square law
Radiolucent

Describes material or tissue that allows X-rays to pass readily, appearing dark on the image. Air in the lungs and gas in bowel are typical examples, in contrast to bone.

Related: Radiopaque, Contrast medium
Radiopaque

Describes material that absorbs X-rays strongly and appears white or light on the image. Bone, metal implants, and positive contrast agents are common examples.

Related: Radiolucent, Contrast medium
Contrast medium

Substance introduced into the body to increase difference in attenuation between structures. Barium sulphate and iodinated compounds are used for gastrointestinal and vascular studies respectively.

Related: Radiopaque, Barium study, Anaphylaxis
Barium study

Examination using barium sulphate suspension to outline the gastrointestinal tract. It is preferred for suspected perforation because it is not absorbed, unlike water-soluble iodinated media.

Related: Contrast medium, Fluoroscopy
Fluoroscopy

Real-time X-ray imaging using a continuous or pulsed beam displayed on a monitor. It guides contrast studies and procedures, and staff must manage dose because exposure times can be long.

Related: Barium study, ALARA principle
Anaphylaxis

Severe, rapidly developing systemic allergic reaction with airway swelling, breathing difficulty, and falling blood pressure. It is a recognised risk of iodinated contrast injection and needs immediate adrenaline and emergency support.

Related: Contrast medium, Informed consent
Informed consent

Voluntary agreement to a procedure given after the patient receives and understands information about its purpose, risks, benefits, and alternatives. It must be documented and can be withdrawn at any time.

Related: Anaphylaxis, Patient confidentiality
Patient confidentiality

Duty to keep a patient's personal and clinical information private and share it only with those involved in care. Breach can harm trust and carries ethical and legal consequences.

Related: Informed consent, Professional accountability
Professional accountability

Obligation of a radiographer to practise within competence, follow protocols, report errors, and put patient safety first. It includes accurate documentation and refusing tasks beyond one's training.

Related: Patient confidentiality, Informed consent