Punjab PSEB Sr. Sec. NSQF Electronics (Solar Panel Installation Technician) key terms
Punjab PSEB Sr. Sec. NSQF Electronics (Solar Panel Installation Technician) · Get comfortable with the vocabulary.
- Photovoltaic effect
- Related: Solar cell, Open-circuit voltage
The process by which a semiconductor material converts absorbed light energy directly into electrical current, releasing electrons that flow through an external circuit when the material is connected to a load.
- Irradiance
- Related: Standard Test Conditions, Peak sun hours
The instantaneous power of sunlight falling on a surface, measured in watts per square metre. Standard test conditions use 1000 W/m², and module output current rises roughly in proportion to this value.
- Peak sun hours
- Related: Irradiance, Array sizing
The daily solar energy received at a site expressed as the number of hours of full 1000 W/m² sunshine it is equivalent to; used to estimate daily energy yield from array capacity.
- Standard Test Conditions
- Related: Irradiance, Temperature coefficient
The laboratory reference conditions for module ratings: 1000 W/m² irradiance, 25 °C cell temperature and a specified air mass spectrum. Nameplate wattage is valid only at these conditions.
- Temperature coefficient
- Related: Standard Test Conditions, Nominal operating cell temperature
The percentage by which module power changes for each degree Celsius rise in cell temperature above 25 °C. Power normally falls as cells heat up, so hot-site output is below the nameplate figure.
- Nominal operating cell temperature
- Related: Temperature coefficient
The cell temperature a module reaches in a standard outdoor test at 800 W/m², 20 °C ambient air and 1 m/s wind. It indicates how much hotter than ambient a module runs.
- I-V curve
- Related: Maximum power point, Fill factor
A graph plotting module current against voltage over the full range from short circuit to open circuit. It shows short-circuit current, open-circuit voltage and the maximum power point where the product is greatest.
- Maximum power point
- Related: I-V curve, MPPT charge controller
The single operating point on a module's I-V curve where current multiplied by voltage is highest. MPPT charge controllers and inverters continuously track this point to extract maximum available energy.
- Fill factor
- Related: I-V curve, Open-circuit voltage
The ratio of a module's maximum power to the product of its open-circuit voltage and short-circuit current. A higher value indicates a squarer I-V curve and better cell quality.
- Open-circuit voltage
- Related: Short-circuit current, Voltage temperature correction
The voltage measured across module terminals with no load connected and full light on the surface. It is the highest voltage the module produces and rises slightly as cell temperature falls.
- Short-circuit current
- Related: Open-circuit voltage, Clamp meter
The current that flows through a module when its terminals are joined by a near-zero-resistance path under illumination. It is roughly proportional to irradiance and is used to check module health.
- Solar cell
- Related: Photovoltaic effect, PV module
The smallest generating unit of a photovoltaic system, usually a silicon wafer with a p-n junction that produces roughly 0.5 to 0.7 V under illumination. Cells are connected in series inside a module.
- PV module
- Related: Solar cell, Bypass diode, Hot spot
A sealed, framed assembly of series-connected solar cells laminated between glass and backsheet, with a junction box and cables. It is the unit sold, transported and mounted on site.
- PV array
- Related: String, PV module
The complete electrical assembly of modules connected in series strings and parallel branches to deliver the required voltage and current to the inverter or charge controller.
- String
- Related: PV array, Voltage temperature correction
A group of modules wired in series so their voltages add while the same current flows through each. String length must respect the inverter's maximum input voltage at the coldest expected temperature.
- Bypass diode
- Related: Hot spot, Blocking diode
A diode inside the module junction box that provides an alternative path around a shaded or faulty cell group, limiting heating and power loss when part of the module is shaded.
- Hot spot
- Related: Bypass diode, Potential induced degradation
A localised overheated area on a cell caused by mismatch, shading or a failed bypass diode, where the shaded cell dissipates power instead of generating it. It can crack glass or start a fire.
- Potential induced degradation
- Related: Hot spot, Earthing
A gradual loss of module power caused by high voltage stress between the cells and the grounded frame, often worsened by moisture and heat. Proper earthing and module choice reduce the risk.
- Monocrystalline module
- Related: Polycrystalline module, Module efficiency
A module made from single-crystal silicon wafers, recognisable by uniform dark colour and cut corners. It offers the highest efficiency per unit area but usually costs more per watt.
- Polycrystalline module
- Related: Monocrystalline module, Temperature coefficient
A module made from multicrystalline silicon, showing a bluish, speckled surface. It is slightly less efficient than monocrystalline but often cheaper, and its output falls more in high heat.
- Thin-film module
- Related: Module efficiency, PV module
A module formed by depositing very thin semiconductor layers such as cadmium telluride or copper indium gallium selenide on a substrate. It is flexible and cheap but needs more area per watt.
- Module efficiency
- Related: Standard Test Conditions, Monocrystalline module
The share of incident solar power that a module converts into electrical power, calculated as maximum power divided by area times 1000 W/m². It determines the roof area needed.
- Tilt angle
- Related: Azimuth, Shading analysis
The angle at which a module surface is raised above the horizontal. In Punjab a tilt near the local latitude, roughly 30 degrees, maximises annual yield and helps rain clean the glass.
- Azimuth
- Related: Tilt angle
The compass direction a module surface faces, measured in degrees from true north. In the northern hemisphere a true-south orientation, about 180 degrees, gives the highest annual energy.
- Shading analysis
- Related: String, Bypass diode
The site assessment that identifies objects or structures casting shadows on the array during the day and year, using a solar path chart or shadow-measuring tool to size the clear area.
- Load assessment
- Related: Array sizing, Battery depth of discharge
The systematic listing of every appliance to be powered, with its wattage and daily hours of use, to calculate total daily energy demand in watt-hours before sizing the array and battery.
- Array sizing
- Related: Load assessment, Peak sun hours
The calculation of module capacity and count needed to meet daily energy demand, dividing load energy by peak sun hours and system losses, then allowing for temperature and dirt derating.
- Battery depth of discharge
- Related: Load assessment, State of charge
The percentage of a battery's capacity that has been withdrawn before recharging. Limiting discharge, typically to 50 percent for lead-acid, extends service life and must be included in sizing.
- State of charge
- Related: Battery depth of discharge, MPPT charge controller
The remaining energy in a battery expressed as a percentage of its full capacity. Charge controllers and battery monitors use voltage or current counting to estimate it and prevent over-discharge.
- MPPT charge controller
- Related: Maximum power point, PWM charge controller
A charge controller that continuously adjusts its input operating point to draw maximum power from the array while converting voltage to suit the battery, giving more yield than simpler controllers.
- PWM charge controller
- Related: MPPT charge controller, State of charge
A charge controller that connects the array to the battery through rapid on-off switching, wasting any array voltage above battery voltage. It suits small systems where array and battery voltages match.
- Grid-tied inverter
- Related: Anti-islanding, Hybrid inverter
An inverter that synchronises its AC output with the utility supply, exporting surplus solar power to the grid and shutting down automatically when the grid fails, as required by anti-islanding protection.
- Hybrid inverter
- Related: Grid-tied inverter, Off-grid inverter
An inverter that manages solar input, battery charging and discharge, and grid or generator supply in one unit, allowing backup power during outages and programmable priority of energy sources.
- Anti-islanding
- Related: Grid-tied inverter, Lockout/tagout
A protective function that stops a grid-tied inverter feeding power within milliseconds of grid failure, preventing electric shock to utility staff repairing lines during an outage.
- MC4 connector
- Related: String, Combiner box
A locking, polarised, touch-protected DC connector used to join module and string cables. Correct crimping with the matching tool and the same brand on both halves prevents heating and fire.
- Combiner box
- Related: String, Surge protective device
An enclosure where several parallel strings are joined onto common busbars, each string protected by a fuse, with a DC isolator and surge protection before a single cable runs to the inverter.
- Earthing
- Related: Surge protective device, Residual current device
Bonding all exposed metalwork, module frames and inverter enclosures to a buried electrode so fault current trips protection devices and touch voltage stays safe for people.
- Surge protective device
- Related: Earthing, Combiner box
A component that diverts brief high-voltage spikes from lightning or switching to earth, protecting modules, inverter and electronics. It is installed on DC and AC sides with short, direct earth connections.
- Residual current device
- Related: Earthing, Insulation resistance test
A protective switch that trips when it detects current leaking to earth through a person or faulty insulation, cutting supply before injury. Solar AC circuits require it for shock protection.
- Insulation resistance test
- Related: Earthing, Multimeter
A test using a high-voltage insulation tester to measure resistance between live conductors and earth, confirming cable and module insulation is sound before energising the system.
- Multimeter
- Related: Clamp meter, Open-circuit voltage
A handheld instrument measuring voltage, current, resistance and continuity. In solar work it checks array polarity, open-circuit voltage, fuse continuity and battery voltage before commissioning.
- Clamp meter
- Related: Multimeter, Short-circuit current
A meter whose jaws encircle a conductor and read current from its magnetic field without breaking the circuit. A DC-capable clamp meter measures string and battery current during testing.
- Voltage temperature correction
- Related: Open-circuit voltage, String
The adjustment of module open-circuit voltage for the coldest expected site temperature, using the datasheet voltage coefficient, to confirm the string never exceeds inverter maximum input voltage.
- Lockout/tagout
- Related: Anti-islanding, Personal protective equipment
A safety procedure in which the energy source is switched off, physically locked and tagged with the holder's name so equipment cannot be re-energised while someone works on it.
- Personal protective equipment
- Related: Lockout/tagout, Fall arrest system
Wearable safety gear for solar work, including insulated gloves, safety helmet, safety harness for roof work, safety footwear, eye protection and high-visibility clothing as the task requires.
- Fall arrest system
- Related: Personal protective equipment
A harness and lanyard arrangement anchored to a certified point that stops a worker's fall from a roof or structure and limits the distance fallen. It is mandatory above height thresholds.
- Ohm's law
- Related: Power calculation, Voltage drop
The relationship stating that voltage equals current multiplied by resistance in a circuit. Technicians use it to find expected current, voltage drop in cables and resistance of loads.
- Power calculation
- Related: Ohm's law, Load assessment
Electrical power in a DC circuit equals voltage multiplied by current, and energy equals power multiplied by time. These formulas underpin load assessment, sizing and customer quotations.
- Voltage drop
- Related: Ohm's law, Cable sizing
The loss of voltage along a cable caused by its resistance, proportional to current, length and conductor resistivity. Keeping it below about 3 percent avoids inverter faults and wasted energy.
- Cable sizing
- Related: Voltage drop, String
Selecting conductor cross-sectional area so current-carrying capacity exceeds expected current while voltage drop and heating stay within limits, accounting for derating in conduit and high ambient temperature.
- Blocking diode
- Related: Bypass diode, String
A diode placed in series with a string or array to prevent reverse current from a stronger string or battery flowing back through weaker modules at night or under mismatch.
- Net metering
- Related: Grid-tied inverter, Government subsidy scheme
A billing arrangement in which surplus solar energy exported to the grid is credited against units imported, so the consumer pays only for the net difference over the billing period.
- Government subsidy scheme
- Related: Net metering, Quotation
A public programme offering capital subsidy or concessional finance for rooftop solar, with eligibility, capacity limits and application through a designated portal. Verify current terms before quoting.
- Quotation
- Related: Government subsidy scheme, Load assessment
A written offer to a customer listing system capacity, equipment makes, scope of work, warranty terms, taxes, subsidy adjustment and total price, with validity period and payment schedule.
- Commissioning
- Related: Insulation resistance test, Performance ratio
The final site process of inspecting, testing and energising the installed system, recording voltages, currents and insulation readings, and handing over documentation and user training to the customer.
- Performance ratio
- Related: Commissioning, Irradiance
The ratio of actual energy generated over a period to the theoretical energy the array would produce at standard conditions, revealing losses from heat, dirt, shading and faults.