Punjab PSEB Sr. Sec. NSQF Telecom (Optical Fibre Technician) flashcards
Punjab PSEB Sr. Sec. NSQF Telecom (Optical Fibre Technician) · Build recall with a focused review session.
36 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Total internal reflection
- The confinement mechanism in optical fibre: light in the higher-index core striking the core–cladding boundary above the critical angle reflects back into the core instead of refracting out.
- Numerical aperture
- NA = √(n1² − n2²), a measure of the fibre's light-gathering cone; its value equals the sine of the maximum acceptance half-angle.
- Single-mode fibre core size
- About 8–10 µm, small enough to support one propagation mode at 1310 and 1550 nm, which removes modal dispersion and allows long-haul transmission.
- Attenuation in decibels
- Loss expressed as 10 log10(Pin/Pout); typical single-mode values are about 0.35 dB/km at 1310 nm and 0.20 dB/km at 1550 nm.
- Rayleigh scattering loss
- Loss from microscopic refractive-index fluctuations frozen into the glass; it scales as 1/λ⁴ and sets the fundamental attenuation floor of silica fibre.
- Twelve-fibre colour code
- Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua; the sequence repeats per tube or group to identify each fibre position.
- Loose-tube cable construction
- Gel-filled tubes each holding 2–12 fibres, wrapped with strength members and a sheath; suited to outdoor duct and aerial routes with wide temperature range.
- Armoured cable purpose
- A corrugated steel tape layer that protects fibres from rodent attack and crush; used in direct-burial routes, often with inner and outer jackets.
- Bend-insensitive G.657 fibre
- A fibre design tolerating much tighter bend radii than G.652.D, preferred for FTTH drop cables and cramped premises wiring where bends are unavoidable.
- LSZH jacket
- Low-smoke zero-halogen sheath material used indoors; it releases little smoke and no corrosive halogen gas in a fire, unlike PVC.
- Cleave angle limit
- For single-mode splicing the cleave end face should be within about 0.5° of perpendicular; a poor cleave raises splice loss or causes arc failure.
- Bare fibre disposal
- Fibre offcuts are sharp and can penetrate skin or eyes; collect them on a dark mat and seal in a sharps container, never in general waste.
- VFL safety check
- A 650 nm visual fault locator confirms whether a fibre is dark before work; never view a fibre end directly because live infrared sources are invisible.
- Fusion splice acceptance loss
- Single-mode splices are typically accepted at ≤0.10 dB, and multimode at ≤0.20 dB, measured on the splicer and confirmed by bidirectional OTDR.
- APC versus UPC connectors
- APC has an 8° angled, typically green end face with ≥60 dB return loss; UPC is flat-polished. Mating APC to UPC causes high loss and damage.
- Mechanical splice
- A clamp-and-gel splice using index-matching gel; quick for restoration, typically 0.1–0.5 dB loss, higher than a good fusion splice.
- Fusion splice sequence
- Strip, clean, cleave, load into V-grooves, align, arc fuse, then apply a heat-shrink protector; each step affects final splice loss.
- Connector insertion loss limit
- A field-installed SC or LC connector is typically accepted at ≤0.3 dB insertion loss, with return loss ≥50 dB for UPC and ≥60 dB for APC.
- Pull tension limit
- Cable must be pulled below its rated maximum tension, commonly 600–2700 N by design; exceeding it stretches fibre and causes permanent loss.
- Installation bend radius
- A common rule is 20× cable diameter under load and 10× after installation; tighter bends cause macrobend loss, first visible at 1625 nm.
- Direct burial depth
- Typically 0.9–1.2 m under roadways with sand bedding and warning tape, shallower in verges; the exact value follows the local utility specification.
- Cable blowing installation
- Cable is propelled through duct or microduct by air pressure and a feeder, reducing tension and allowing long runs compared with pulling.
- OTDR distance formula
- Distance d = (c × t)/(2 × IOR), where t is round-trip time and IOR is the group index, about 1.468 for G.652 at 1550 nm.
- OTDR pulse width trade-off
- Short pulses resolve closely spaced events near the launch; long pulses reach farther but blur nearby events and reduce spatial resolution.
- Bidirectional OTDR testing
- Measuring a splice from both ends and averaging removes the apparent gain or loss error caused by backscatter differences between the two fibres.
- Link loss budget
- Total allowed loss equals fibre loss plus connector and splice losses plus a margin, usually about 3 dB, compared with the transceiver's specified budget.
- GPON wavelengths
- GPON uses 1490 nm downstream, 1310 nm upstream and 1550 nm for video overlay; testing at the wrong wavelength misrepresents live PON loss.
- Splitter loss values
- Typical insertion loss is about 10.5 dB for 1:8, 13.5 dB for 1:16 and 16.5 dB for 1:32, plus excess loss, and must be included in the FTTH budget.
- ONT receive power range
- GPON ONTs typically accept about −8 to −27 dBm; a reading outside this range indicates a dirty connector, bend, or excessive splitter loss.
- FTTH drop cable handling
- Flat 1–2 fibre drop cable with FRP strength members must be clamped, not stapled through, and routed within its bend radius away from electrical cabling.
- Baseline OTDR trace
- A stored trace per fibre and wavelength taken after commissioning; later faults are found by comparing current traces with this reference.
- Splice schedule document
- A record mapping each fibre and tube colour to its splice position, closure and port; it must be updated after every splice or re-termination.
- Fault ticket content
- A record of alarm time, affected services, test results, restoration action and root cause, used for SLA reporting and trend analysis.
- NSQF level meaning
- A national skills framework level describing responsibility and autonomy, from supervised work at lower levels to independent and supervisory roles higher up.
- Technical fault reporting
- Reporting with specific data such as fibre ID, wavelength, measured loss in dB and fault distance in metres, rather than general descriptions of poor service.
- Contractor cost estimation
- Calculating cost per splice or per kilometre from labour, materials and equipment depreciation, then adding margin and taxes before quoting a client.