RRB ECG Technician · Get comfortable with the vocabulary.

Sinoatrial (SA) node

The heart's natural pacemaker, a small cluster of specialised cells in the right atrium that spontaneously depolarises at roughly 60 to 100 times per minute and sets the normal rhythm.

Related: P wave, Sinus rhythm, Atrioventricular (AV) node
Atrioventricular (AV) node

A relay station of specialised conducting cells between the atria and ventricles that delays the electrical impulse briefly, allowing the atria to empty before the ventricles contract.

Related: PR interval, Sinoatrial (SA) node, Bundle of His
Bundle of His

The continuation of the AV node into the interventricular septum, which splits into right and left bundle branches and carries the impulse rapidly toward the ventricles.

Related: Atrioventricular (AV) node, Purkinje fibres, QRS complex
Purkinje fibres

Fast-conducting fibres spreading through the ventricular walls that distribute the electrical impulse to ventricular muscle, producing rapid, coordinated contraction.

Related: Bundle of His, QRS complex
P wave

The first deflection on an ECG, a small rounded wave representing atrial depolarisation; its shape, width and height help identify atrial enlargement or an ectopic atrial pacemaker.

Related: Sinoatrial (SA) node, PR interval, Sinus rhythm
PR interval

The time from the start of the P wave to the start of the QRS complex, normally 0.12 to 0.20 seconds; prolongation suggests delayed conduction through the AV node.

Related: Atrioventricular (AV) node, First-degree AV block, P wave
QRS complex

The sharp deflection representing ventricular depolarisation, normally narrow (under 0.12 seconds); widening suggests a conduction delay such as bundle branch block or a ventricular origin.

Related: Bundle branch block, Purkinje fibres, T wave
T wave

The deflection after the QRS complex that reflects ventricular repolarisation; it is normally upright in most leads and can become inverted, flat or peaked in ischaemia and electrolyte disturbance.

Related: ST segment, Hyperkalaemia, QRS complex
ST segment

The flat section between the end of the QRS complex and the start of the T wave; elevation or depression relative to baseline is a key sign of myocardial injury or ischaemia.

Related: ST elevation, T wave, Ischaemia
Sinus rhythm

A normal rhythm originating in the SA node, showing upright P waves before every QRS complex at a regular rate between 60 and 100 beats per minute.

Related: Sinoatrial (SA) node, Sinus bradycardia, P wave
Sinus bradycardia

A sinus rhythm slower than 60 beats per minute; it may be normal in athletes or during sleep but can cause dizziness and low blood pressure when the rate is inadequate.

Related: Sinus rhythm, Sinus tachycardia
Sinus tachycardia

A sinus rhythm faster than 100 beats per minute, typically a physiological response to fever, pain, exercise, anxiety, anaemia or hypovolaemia rather than a primary rhythm disorder.

Related: Sinus rhythm, Sinus bradycardia
Atrial fibrillation

An irregularly irregular rhythm with absent P waves and fibrillatory baseline activity, caused by chaotic atrial activation; it carries a risk of clot formation and stroke.

Related: Irregularly irregular rhythm, P wave, Heart rate calculation
Irregularly irregular rhythm

A rhythm in which R-R intervals vary unpredictably from beat to beat with no repeating pattern, the classic hallmark of atrial fibrillation.

Related: Atrial fibrillation, Heart rate calculation
Heart rate calculation

Deriving beats per minute from an ECG, commonly by dividing 300 by the number of large squares between R waves, or by counting QRS complexes in a 10-second strip and multiplying by six.

Related: R-R interval, Irregularly irregular rhythm
R-R interval

The distance between two consecutive R waves, used to judge rhythm regularity and to calculate heart rate; it should be measured consistently across the strip.

Related: Heart rate calculation, Atrial fibrillation
First-degree AV block

A consistent prolongation of the PR interval beyond 0.20 seconds in which every P wave is still followed by a QRS complex; usually benign but worth documenting.

Related: PR interval, Atrioventricular (AV) node
Bundle branch block

Delayed conduction down the right or left bundle branch, producing a widened QRS complex (0.12 seconds or more) with a characteristic pattern in the chest leads.

Related: QRS complex, Bundle of His
Premature ventricular contraction (PVC)

An early beat arising from ventricular muscle, shown as a wide, bizarre QRS complex without a preceding P wave, often followed by a compensatory pause.

Related: QRS complex, P wave
Ventricular tachycardia

A run of three or more consecutive ventricular beats at a fast rate, appearing as wide QRS complexes; it is a medical emergency because it can deteriorate into ventricular fibrillation.

Related: Ventricular fibrillation, Premature ventricular contraction (PVC)
Ventricular fibrillation

Chaotic, disorganised electrical activity with no identifiable P waves, QRS complexes or T waves and no effective cardiac output; it requires immediate defibrillation and cardiopulmonary resuscitation.

Related: Ventricular tachycardia, Defibrillation safety
ST elevation

Upward displacement of the ST segment above the isoelectric line, suggesting acute transmural myocardial injury; it demands urgent medical review and repeat tracing.

Related: ST segment, Ischaemia, Myocardial infarction
Ischaemia

Inadequate blood flow to heart muscle, which on ECG commonly appears as ST depression, T wave inversion or flattening in the affected leads without necessarily showing infarction.

Related: ST segment, Myocardial infarction, ST elevation
Myocardial infarction

Death of heart muscle due to blocked coronary blood flow, shown on ECG by ST elevation, pathological Q waves or new T wave changes depending on the stage and site.

Related: ST elevation, Ischaemia, Pathological Q wave
Pathological Q wave

An abnormally deep or wide Q wave, often indicating previous full-thickness myocardial infarction in the territory of the leads where it appears.

Related: Myocardial infarction
Einthoven's triangle

The geometric arrangement of the three limb leads I, II and III, which view the heart from three directions and together form the basis of the frontal plane recording.

Related: Limb leads, Chest leads
Limb leads

Six frontal-plane leads: bipolar I, II and III plus augmented aVR, aVL and aVF, formed from electrodes on the arms and legs; lead II is commonly used for rhythm monitoring.

Related: Einthoven's triangle, Chest leads, Lead placement
Chest leads

Six unipolar precordial leads V1 to V6 placed across the chest, which record the heart's electrical activity in the horizontal plane and help localise ischaemia or hypertrophy.

Related: Limb leads, Lead placement
Lead placement

Correct positioning of electrodes for a 12-lead ECG, including limb electrode sites and the standard V1 to V6 chest positions; errors cause misdiagnosis and must be avoided.

Related: Chest leads, Limb leads, Wandering baseline
Calibration mark

The rectangular pulse at the start of a tracing showing that 1 millivolt equals 10 millimetres vertically, allowing correct interpretation of wave heights and amplitudes.

Related: Paper speed, Baseline artefact
Paper speed

The rate at which the ECG paper or digital display advances, standardly 25 millimetres per second, which fixes the time scale used to measure intervals and rate.

Related: Calibration mark, Heart rate calculation
Wandering baseline

Slow up-and-down drift of the tracing caused by patient movement, breathing, poor electrode contact or loose cables; it can mimic or hide ST segment changes.

Related: Baseline artefact, Lead placement, Somatic tremor artefact
Somatic tremor artefact

Rapid, fuzzy, irregular oscillation on the tracing produced by muscle activity such as shivering, tension or talking, which can obscure small waveforms.

Related: Wandering baseline, Baseline artefact
Baseline artefact

Any unwanted disturbance of the isoelectric line, including drift, tremor or electrical interference, that reduces tracing quality and must be corrected before interpretation.

Related: Wandering baseline, Somatic tremor artefact, AC interference
AC interference

Regular high-frequency fuzz at 50 or 60 hertz caused by nearby electrical equipment or poor electrode contact, producing a thick, unreadable baseline on the ECG.

Related: Baseline artefact, Electrode contact
Electrode contact

The quality of the electrical connection between skin and electrode; cleaning the skin, clipping hair and using fresh gel or pads improves contact and reduces artefact.

Related: AC interference, Wandering baseline
Defibrillation safety

Precautions when a shock may be delivered, including ensuring nobody touches the patient or bed, oxygen is moved away, and the operator announces and confirms 'clear' before discharge.

Related: Ventricular fibrillation, Infection control
Infection control

Practices such as hand hygiene, clean or disposable electrodes, and disinfection of cables and machine parts between patients to prevent transmission of microorganisms in the ECG room.

Related: Electrode contact, Informed consent
Informed consent

Explaining the purpose, procedure and privacy aspects of an ECG to the patient and obtaining voluntary agreement before recording, respecting the right to refuse or ask questions.

Related: Patient privacy, Infection control
Patient privacy

Protecting the patient's dignity and personal health information during ECG recording by using screens or curtains, exposing only necessary skin, and keeping records confidential.

Related: Informed consent