Anatomical position

The standard reference stance in which a person stands upright, faces forward, arms hang at the sides with palms turned forward, and feet point ahead, so that all body directions and limb alignments can be described consistently.

Related: Proximal and distal, Range of motion
Proximal and distal

Directional words describing position along a limb: proximal means nearer to the trunk or root of the limb, while distal means farther from it, toward the hand or foot. These terms guide socket trim lines and component placement.

Related: Anatomical position, Residual limb
Range of motion

The measured arc through which a joint can move, usually expressed in degrees and recorded as active when the patient moves it or passive when the examiner moves it. It sets goals for prosthetic and orthotic design.

Related: Contracture, Goniometer
Contracture

A permanent shortening of muscle and connective tissue around a joint that limits movement and cannot be corrected by passive stretching alone. It commonly follows disuse or poor positioning and may prevent comfortable prosthetic fitting.

Related: Range of motion, Residual limb
Residual limb

The portion of a limb remaining after amputation, including bone, muscle, scar, and soft tissue. Its length, shape, sensation, and healing quality strongly influence socket design and comfort.

Related: Proximal and distal, Socket
Load-bearing areas

Regions of the residual limb or body that can safely tolerate pressure from a prosthesis or orthosis, such as the patellar tendon bar area in a below-knee limb. Identifying them prevents skin damage during weight bearing.

Related: Pressure-tolerant and pressure-sensitive areas, Socket
Pressure-tolerant and pressure-sensitive areas

A mapping of the limb surface into zones that can accept load and zones that cannot, such as bony prominences, scars, and nerve pathways. Socket and orthosis shapes are modified so force is shifted away from sensitive zones.

Related: Load-bearing areas, Relief
Relief

A localized hollow or added space built into a cast, positive model, or socket wall so that a bony prominence, tender scar, or artery is not pressed during wear. It is created by adding padding before casting or by carving the model.

Related: Pressure-tolerant and pressure-sensitive areas, Positive model
Negative cast

A hollow impression of the limb taken in plaster or a similar material, capturing its shape in reverse. It is filled with plaster to produce a positive model used for socket fabrication.

Related: Positive model, Rectification
Positive model

A solid replica of the limb produced by filling a negative cast, then corrected and smoothed before being used to form a socket or orthosis. It carries all modifications such as reliefs, buildups, and trim lines.

Related: Negative cast, Rectification
Rectification

The deliberate reshaping of a positive model by adding or removing material so the finished socket loads tolerant areas, relieves sensitive ones, and controls suspension. It converts an anatomical copy into a functional interface.

Related: Positive model, Relief
Socket

The hollow, custom-formed part of a prosthesis that receives the residual limb and transmits body weight and control forces to the rest of the device. Its fit, shape, and suspension determine comfort and function.

Related: Residual limb, Suspension
Suspension

The method that holds a prosthesis on the limb during swing and lift, using suction, a liner and pin, a belt, a sleeve, or anatomical locking. Poor suspension causes pistoning, rubbing, and loss of control.

Related: Socket, Pistoning
Pistoning

Up-and-down sliding of the residual limb inside the socket during walking, caused by a loose fit, weak suspension, or volume change. It produces friction, skin breakdown, and reduced control of the prosthesis.

Related: Suspension, Volume management
Volume management

Monitoring and controlling changes in residual limb size using shrinkers, elastic wrapping, prosthetic socks, or socket adjustments. Limb volume shifts with swelling, weight change, and activity, so fit must be rechecked regularly.

Related: Pistoning, Residual limb
Bench alignment

The initial setup of prosthetic components on a workbench using reference lines and the manufacturer's suggested angles before the patient stands in the device. It gives a sound starting point for later dynamic adjustment.

Related: Dynamic alignment, Trochanteric line
Dynamic alignment

Fine adjustment of the prosthesis while the patient stands and walks, changing angles, shifts, and lengths until gait is stable and comfortable. It relies on observation and patient feedback rather than bench measurements alone.

Related: Bench alignment, Gait cycle
Trochanteric line

A vertical reference line dropped from the greater trochanter of the femur, used in bench and static alignment to judge whether the socket and foot are correctly positioned relative to the body's line of weight bearing.

Related: Bench alignment, Weight line
Gait cycle

One complete sequence of walking from initial contact of one foot to the next contact of the same foot, divided into stance and swing phases. Understanding it is essential for identifying deviations and tuning alignment.

Related: Stance phase, Swing phase
Stance phase

The part of the gait cycle when the foot is on the ground and bearing weight, normally about sixty percent of the cycle. It is when stability, knee control, and prosthetic foot function are tested most.

Related: Gait cycle, Swing phase
Swing phase

The part of the gait cycle when the foot is off the ground and moving forward, normally about forty percent of the cycle. Clearance, knee flexion, and suspension are mainly judged during this phase.

Related: Gait cycle, Stance phase
Goniometer

An instrument with a hinged arm and protractor scale used to measure joint angles and range of motion. Measurements taken with it document baseline function and guide prosthetic or orthotic prescription.

Related: Range of motion, Residual limb
Thermoplastic

A polymer that softens when heated and hardens on cooling, so it can be reshaped repeatedly. Materials such as polypropylene and polyethylene are widely used for prosthetic sockets and orthotic shells.

Related: Thermoset resin, Vacuum forming
Thermoset resin

A polymer that cures permanently through a chemical reaction and cannot be remelted or reshaped. Acrylic and epoxy resins are used for laminating sockets and for rigid orthotic components.

Related: Thermoplastic, Lamination
Lamination

Building a rigid prosthetic or orthotic shell by laying reinforcing fabric such as fiberglass or carbon fiber over a model and saturating it with resin that then cures. Resin-to-fiber ratio strongly affects strength and weight.

Related: Thermoset resin, Carbon fiber composite
Carbon fiber composite

A material of carbon fibers embedded in resin, giving very high stiffness and strength at low weight. It is common in energy-storing feet, lightweight sockets, and orthotic frames.

Related: Lamination, Thermoplastic
Vacuum forming

A fabrication method in which a heated thermoplastic sheet is drawn tightly over a positive model by suction, then cooled to hold the shape. It produces thin, even sockets and orthotic shells with good reproduction of detail.

Related: Thermoplastic, Positive model
Biocompatibility

The ability of a material in contact with skin or tissue to avoid causing irritation, allergy, or toxic reaction. It is a key selection criterion for liners, adhesives, and any device worn against the body.

Related: Skin breakdown, Silicone liner
Silicone liner

A soft, elastic sleeve worn between the residual limb and the socket to cushion pressure, protect skin, and assist suspension, often with a locking pin or sealing rings. Its thickness and stiffness affect comfort and control.

Related: Suspension, Biocompatibility
Ischial seat

The part of a below-knee prosthetic socket or orthosis that bears weight under the ischial tuberosity, helping control rotation and provide a stable sitting surface. Its position is checked during fitting and alignment.

Related: Load-bearing areas, Socket
Patellar tendon bar

A prominent ridge built into the front of a below-knee socket that presses just below the kneecap on the patellar tendon, a pressure-tolerant area. It helps suspend the socket and resist rotation.

Related: Load-bearing areas, Socket
Ankle-foot orthosis

A device worn around the lower leg and foot that controls ankle motion and position, commonly used to correct drop foot or provide stability. It may be made of plastic, metal, or carbon composite.

Related: Three-point force system, Orthosis
Three-point force system

A principle in orthotics and fracture bracing in which forces applied at three points create a bending moment that holds a limb or joint in a corrected position. The middle force is opposite the two end forces.

Related: Ankle-foot orthosis, Orthosis
Orthosis

An externally applied device that supports, aligns, protects, or corrects a body segment or joint. Unlike a prosthesis, it works alongside an existing body part rather than replacing a missing one.

Related: Ankle-foot orthosis, Prosthesis
Prosthesis

An artificial device that replaces a missing body part, such as a hand, leg, or eye, and aims to restore appearance or function. Its design must balance comfort, durability, and the patient's daily needs.

Related: Orthosis, Socket
Myoelectric control

Operation of an electric hand or arm by electrical signals picked up from muscles on the residual limb using surface electrodes. It requires good electrode contact and patient training to produce reliable, repeatable grips.

Related: Body-powered prosthesis, Electromyography
Body-powered prosthesis

An upper-limb prosthesis operated by a harness and cable that transmits shoulder and trunk movement to open a terminal device. It is durable, light, and gives useful feedback through the cable tension.

Related: Myoelectric control, Terminal device
Terminal device

The hand or hook at the end of an upper-limb prosthesis that grips objects. Hooks offer precision and visibility, while prosthetic hands give a more natural appearance and broader contact surface.

Related: Body-powered prosthesis, Myoelectric control
Skin breakdown

Damage to the skin from prolonged pressure, shear, or friction against a device, ranging from redness to open sores. It signals poor fit or hygiene and must be addressed before the device is worn again.

Related: Biocompatibility, Pistoning
Phantom limb sensation

The experience of feeling or sensing a limb that has been amputated, which is common and usually fades over time. It differs from phantom pain and should be discussed openly with the patient during assessment.

Related: Residual limb, Desensitization
Desensitization

A graded rehabilitation technique in which the residual limb is progressively exposed to touch, tapping, and pressure to reduce hypersensitivity and prepare it for socket wear. It is taught as a home exercise.

Related: Phantom limb sensation, Residual limb
Occupational hazard

Any condition, material, or action in the workshop that can harm health, such as dust, fumes, noise, sharp tools, or heavy lifts. Recognizing hazards is the first step in controlling risk.

Related: Personal protective equipment, Machine guarding
Personal protective equipment

Wearable gear such as goggles, gloves, dust masks, and hearing protection that reduces exposure to workshop hazards. It is a last line of defense and does not replace proper guards, ventilation, or safe methods.

Related: Occupational hazard, Machine guarding
Machine guarding

Physical barriers and interlocks fitted around moving parts of tools such as saws, drills, and grinders to prevent contact with hands or clothing. Guards must never be removed or bypassed during work.

Related: Personal protective equipment, Occupational hazard
Informed consent

A patient's voluntary agreement to a procedure after receiving clear information about its purpose, benefits, risks, and alternatives. It respects autonomy and must be documented before fitting or treatment begins.

Related: Confidentiality, Patient assessment
Confidentiality

The ethical duty to keep a patient's personal and medical information private and share it only with those who need it for care. It builds trust and is a legal obligation in most settings.

Related: Informed consent, Patient assessment
Patient assessment

A structured evaluation of a patient's history, physical condition, limb shape, mobility, and goals before designing a prosthesis or orthosis. It gathers the facts that justify the prescription and fitting plan.

Related: Goniometer, Informed consent