IN Water/WW Operator study materials
IN Water/WW Operator study resources

IN Water/WW Operator cheat sheet

IN Water/WW Operator · Keep the key ideas within reach.

Quick reference

Water Treatment

  • Coagulation (alum, ferric salts, cationic polymer) destabilizes colloidal particles; alum generally performs best near pH 5.5-6.5 for turbidity removal.

  • Flocculation is gentle tapered mixing (velocity gradient G roughly 10-75 s^-1 for 15-45 minutes) so destabilized particles collide and grow into settleable floc.

  • Sedimentation sizing: surface overflow rate = flow / surface area; particles whose settling velocity is below the overflow rate carry over in the effluent.

  • Rapid sand filtration loading is about 2-5 gpm/ft2; backwash runs 15-20 gpm/ft2 with roughly 20-30 percent bed expansion, often with air scour.

  • CT = disinfectant residual (mg/L) x contact time (minutes); the required CT for free chlorine rises as pH increases and as water temperature falls.

  • Chlorine demand = applied dose minus residual; finished water typically leaves the plant with a free chlorine residual of at least 0.2 mg/L.

  • Conventional filtration turbidity limits: combined filter effluent at or below 0.3 NTU in 95 percent of monthly samples and never above 1 NTU.

  • Lime softening: a first stage near pH 9.5 precipitates calcium carbonate; a second stage near pH 10.5-11 precipitates magnesium hydroxide.

  • MF and UF membranes remove particles and pathogens; NF and RO remove dissolved ions and are rated by molecular weight cutoff or salt rejection rather than pore size.

Quick reference

Water Distribution

  • Static pressure equals 0.433 psi per foot of elevation; a tank water surface 100 feet above a tap produces about 43.3 psi at that tap.

  • Hazen-Williams head loss hL = 10.44 L Q^1.852 / (C^1.852 d^4.87) in US units; higher C means smoother pipe, about 130-140 for new cement-lined or PVC main.

  • A common regulatory minimum is 20 psi anywhere in the system under all flow conditions, while design targets are usually 35-50 psi at customer meters.

  • A detectable disinfectant residual must be carried throughout the system; many primacy agencies require at least 0.2 mg/L free chlorine at representative points.

  • Water hammer controls include slow-closing valves, surge tanks, air and vacuum release valves, and pump bypass or flywheel arrangements.

  • Backflow protection hierarchy: air gap is best, then reduced-pressure principle assembly, then double check valve, then vacuum breaker; only testable assemblies resist backpressure.

  • Unidirectional flushing targets at least 2.5-3 ft/s to scour sediment; dead-end mains are flushed on a schedule to limit stagnation and biofilm growth.

  • Leak detection pairs minimum night flow analysis with acoustic correlation; a rising 2-4 a.m. baseline flow indicates unreported leakage.

Quick reference

Wastewater Treatment

  • BOD5 is measured after 5 days of incubation at 20 degrees Celsius; nitrification must be inhibited when only carbonaceous oxygen demand is reported.

  • Activated sludge F/M = lb BOD applied per day / lb MLVSS under aeration; conventional plants run 0.2-0.5 per day and extended aeration runs below 0.1 per day.

  • MCRT (SRT) sets the biomass inventory; nitrification generally needs SRT of at least 10 days at 20 degrees C and longer in cold water.

  • Dissolved oxygen in the aerobic basin is held near 1.5-3.0 mg/L; aeration blowers are normally the plant's largest energy consumer.

  • RAS returns 50-100 percent of influent flow, WAS controls SRT, and SVI of 80-150 mL/g indicates good settling while values above 200 mL/g indicate filamentous bulking.

  • Secondary clarifier design values are about 400-800 gpd/ft2 overflow rate and no more than 25-30 lb/day/ft2 solids loading at peak flow.

  • Nitrification consumes about 7.14 mg alkalinity as CaCO3 and 4.57 mg O2 per mg NH3-N oxidized; denitrification recovers roughly 2.86 mg O2 per mg NO3-N.

  • Mesophilic anaerobic digestion runs at 35-38 degrees C with a 20-30 day SRT, destroying 40-50 percent of volatile solids and producing biogas of about 60-65 percent methane.

Quick reference

Wastewater Collection

  • Gravity sewers are designed for a self-cleansing velocity near 2 ft/s, with scour risk above roughly 10-15 ft/s in concrete pipe.

  • Typical minimum slopes are about 0.40 percent for 8-inch, 0.28 percent for 10-inch, and 0.22 percent for 12-inch pipe, chosen to deliver 2 ft/s at design average flow.

  • Manning equation: V = (1.486/n) R^(2/3) S^(1/2), with n near 0.013 for new concrete or VCP and 0.015 or higher for old or rough pipe.

  • Sanitary sewers convey domestic and industrial flow to treatment, storm sewers discharge directly to receiving waters, and combined sewers overflow as CSOs in wet weather.

  • Force mains need at least 2 ft/s to keep solids suspended, and designers often check the system against a 3-5 ft/s scouring criterion.

  • I/I reduction uses smoke testing, dye testing, CCTV inspection, and joint or CIPP rehabilitation; excessive I/I is a leading cause of sanitary sewer overflows.

  • Wet well pump cycling targets a minimum cycle time of about 10-15 minutes; pumps alternate to equalize wear and VFDs soften surge.

Quick reference

Safety

  • Confined space entry atmosphere limits: oxygen 19.5-23.5 percent, LEL below 10 percent, hydrogen sulfide below 10 ppm, carbon monoxide below 35 ppm, monitored continuously.

  • Hydrogen sulfide has an odor threshold near 0.01-0.3 ppm, causes olfactory fatigue above about 10 ppm, and has an IDLH of 100 ppm; it is heavier than air.

  • Methane is flammable in air between a 5 percent lower explosive limit and a 15 percent upper explosive limit and accumulates in vaults and wet wells.

  • Chlorine gas is roughly 2.5 times heavier than air and has an IDLH of 10 ppm; leaking gas collects at low points and response requires SCBA with an escape pack.

  • Excavations 5 feet deep or more require a protective system, 20 feet or more require an engineered design, and a competent person inspects daily and after rain.

  • Spoil, tools, and materials stay at least 2 feet back from the trench edge, and ladders must be within 25 feet of lateral travel for every worker.

  • Lockout/tagout requires isolating every energy source, verifying zero energy, applying personal locks, and removal only by the person who applied the lock.

  • Engine-driven equipment in sewers and wet wells adds carbon monoxide and exhaust gases that can displace oxygen, so the atmosphere is tested before and during entry.

Quick reference

Regulations

  • The Safe Drinking Water Act of 1974 sets national primary standards; states that obtain primacy enforce the rules and certify distribution and treatment operators.

  • Total coliform rule: no more than 5 percent of monthly samples may be total-coliform positive, and any routine sample positive for E. coli is an MCL violation.

  • Lead and copper action levels are 0.015 mg/L for lead and 1.3 mg/L for copper at the 90th percentile; exceedance triggers corrosion control and public education.

  • Disinfection byproduct limits are 80 micrograms per liter for total trihalomethanes and 60 micrograms per liter for HAA5, evaluated as locational running annual averages.

  • Primary MCL examples: nitrate 10 mg/L as nitrogen, nitrite 1 mg/L, arsenic 0.010 mg/L, and fluoride 4.0 mg/L.

  • The Clean Water Act of 1972 created NPDES permits with effluent limits; sanitary sewer overflows and combined sewer overflows must be reported to the state agency.

  • 40 CFR Part 503 governs biosolids, including pathogen reduction, vector attraction reduction, and ceiling concentrations for metals.

  • Public notice deadlines are 24 hours for Tier 1, 30 days for Tier 2, and one year for Tier 3; the annual Consumer Confidence Report covers the prior calendar year.

Quick reference

Administration

  • Capacity reviews examine technical, managerial, and financial (TMF) capacity, and new systems must demonstrate capacity before state approval.

  • Retain monitoring data, chain-of-custody forms, and operating logs for the period set by the primacy agency, commonly at least 3-5 years and longer for some records.

  • Budgets separate O&M costs (chemicals, power, labor) from capital costs (replacement, expansion); rates must fund both plus a capital reserve.

  • Preventive maintenance intervals come from manufacturer recommendations, run hours, and condition monitoring, with a work order system documenting completion.

  • Emergency response plans list personnel roles, mutual aid agreements, notification lists, and alternate water or power sources; AWIA adds risk and resilience assessments for larger systems.

  • Operator certification requires continuing education units each renewal cycle and a certified operator in charge at the grade matching the facility classification.

  • A cross-connection control program needs an ordinance, site surveys, device installation, annual testing by certified testers, and recordkeeping.