IN Water/WW Operator flashcards
IN Water/WW Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT value
- Product of disinfectant residual concentration in mg/L and contact time in minutes, used to demonstrate inactivation credit; the required CT increases at higher pH and lower water temperature.
- Jar test
- Bench-scale test using multiple beakers with different coagulant doses and mixing speeds to find the chemical dose and pH that produce the clearest settled water.
- Surface overflow rate
- Clarifier design value equal to flow divided by surface area, in gpm/ft2 or m3/m2-h; particles settling slower than this rate leave with the effluent.
- Filter backwash rate
- Upward flow rate that expands and cleans granular filter media, typically 15 to 20 gpm/ft2 for rapid sand filters, often assisted by air scour.
- Lime softening
- Process that adds hydrated lime to raise pH so calcium carbonate precipitates, then adds more lime at higher pH to remove magnesium as magnesium hydroxide.
- Pressure per foot of elevation
- A column of water one foot high exerts 0.433 psi, so a tank surface 100 feet above a service connection provides about 43 psi static pressure.
- Water hammer
- Pressure surge caused by rapid flow velocity changes when valves close or pumps stop, controlled with slow-closing valves, surge tanks, and air release valves.
- Hazen-Williams coefficient C
- Roughness factor in the Hazen-Williams head loss equation; higher values mean smoother pipe, with about 130 to 140 for new cement-lined or plastic main.
- Air gap
- Physical separation between a potable water outlet and the flood level of the receiving vessel, giving the highest degree of backflow protection with no mechanical parts.
- BOD5
- Biochemical oxygen demand measured after five days of incubation at 20 degrees Celsius; it approximates biodegradable organic matter and is used to size aeration basins and set permit limits.
- F/M ratio
- Food-to-microorganism ratio in activated sludge, pounds of BOD applied per day divided by pounds of mixed liquor volatile solids under aeration, typically 0.2 to 0.5 per day.
- Sludge volume index
- Milliliters of sludge settled in 30 minutes per gram of mixed liquor suspended solids; about 80 to 150 indicates good settling and above 200 indicates bulking.
- Nitrification alkalinity demand
- Oxidizing one milligram of ammonia nitrogen to nitrate consumes about 7.14 milligrams of alkalinity as calcium carbonate, so nitrifying plants may need alkalinity supplementation.
- Return activated sludge rate
- Flow of settled sludge returned from the secondary clarifier to the aeration basin, commonly 50 to 100 percent of influent flow, to hold the target mixed liquor solids.
- Self-cleansing velocity
- Minimum velocity of about 2 feet per second in a gravity sewer that keeps grit and solids moving; velocities above 10 to 15 feet per second cause scour.
- Manning equation
- Open-channel flow formula in US units: velocity equals 1.486 divided by roughness n, times hydraulic radius to the two-thirds power, times slope to the one-half power.
- Infiltration and inflow
- Infiltration is groundwater seeping through defective pipe joints and walls; inflow is storm water entering manholes, roof drains, and illegal connections. Both add clear water to sanitary sewers.
- Smoke testing
- Blowing non-toxic smoke into a sewer section so it escapes at illegal storm connections, broken pipe, and defective manholes, revealing where clear water enters.
- Confined space oxygen range
- Acceptable entry atmosphere is 19.5 to 23.5 percent oxygen; below 19.5 percent is oxygen deficient and above 23.5 percent sharply increases fire risk.
- Hydrogen sulfide IDLH
- The immediately dangerous to life or health concentration for hydrogen sulfide is 100 ppm; the gas deadens the sense of smell, so odor is not a reliable warning.
- Methane explosive range
- Methane forms a flammable mixture in air between about 5 percent lower explosive limit and 15 percent upper explosive limit, levels that can occur in sewers and wet wells.
- Trench protective system
- Sloping, shoring, or shielding required for excavations 5 feet deep or more, with daily inspection by a competent person and spoil kept 2 feet from the edge.
- Chlorine gas properties
- Chlorine is about 2.5 times heavier than air, so leaks collect in low areas; the IDLH is 10 ppm and responders need SCBA with an escape pack.
- Lead and copper action level
- The 90th percentile tap sample must not exceed 0.015 mg/L lead or 1.3 mg/L copper; exceeding either triggers corrosion control treatment, public education, and source water evaluation.
- Total trihalomethane maximum
- The maximum contaminant level for total trihalomethanes is 80 micrograms per liter, calculated as a locational running annual average at each monitoring location.
- Nitrate maximum contaminant level
- The MCL for nitrate is 10 mg/L measured as nitrogen; higher levels cause methemoglobinemia in infants, so systems must notify the public quickly.
- Tier 1 public notice
- Required within 24 hours when a violation carries immediate health risk, such as an E. coli positive or nitrate exceedance, delivered by media, hand delivery, or posting.
- Triple bottom line capacity
- States evaluate water systems on technical, managerial, and financial capacity, which together show ability to reliably comply with rules and fund improvements.
- Asset management plan
- Inventory of assets with condition, criticality, and replacement cost, used to schedule preventive maintenance and capital renewal at the lowest life-cycle cost.
- Chain of custody
- Written record of each sample's handling from collection through laboratory analysis, including times, preservatives, and signatures, which makes results legally defensible.
- Risk and Resilience Assessment
- Under America's Water Infrastructure Act, community systems serving 3,300 or more people assess risks to critical assets and document emergency response, updating every five years.
- Emergency response plan
- Document assigning staff roles, mutual aid agreements, notification lists, and alternate water or power sources so service can be restored and the public warned during incidents.