InterNACHI CPI flashcards
InterNACHI CPI · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Standard of Practice
- The published minimum baseline defining which systems a CPI inspects, how they are observed, and what must be reported; it sets scope but is not a technical standard for adequacy of construction.
- Material defect
- A condition that significantly affects value, desirability, or safety of the property, or that would impair normal use; it is reported, unlike cosmetic or routine maintenance items.
- Readily accessible
- A component that can be observed without moving personal property, dismantling, or using destructive measures; concealed or obstructed items are excluded from the visual inspection.
- Inspection agreement
- The signed contract stating scope, limitations, exclusions, fee, and dispute-resolution terms; it must be in place before or at the start of the inspection.
- Report description requirement
- The report must identify the type and material of each inspected system, not only list defects, so the client understands what was examined and its general condition.
- Ancillary services
- Additional offerings such as radon, mold, septic, well, or pool inspection that fall outside the standard scope and require separate agreement, fee, and often separate credentials.
- Not inspected vs absent
- Distinct report categories: an item not inspected was inaccessible or excluded, while an absent item does not exist; conflating them misstates the inspection scope.
- Negative grading
- Soil that slopes toward the foundation, directing surface water against the structure; a reportable water-management defect that can cause basement or crawlspace moisture problems.
- Roof access limitation
- When the roof is not walked, the report must state the observation method used and the reason for limited access, such as pitch, weather, or fragile covering.
- Double-tapped breaker
- Two conductors terminated under a breaker lug designed for one; a reportable panel defect unless the breaker is listed for two conductors.
- TPR discharge rule
- The temperature-pressure relief valve discharge pipe must terminate within about 6 inches of the floor, be full size, not capped, and not reduced; violations are safety hazards.
- Service amperage
- The rated capacity of the electrical service, determined from the main disconnect or service conductors; it is described in the report along with the service type.
- Combustion air
- Air supplied to a fuel-burning appliance for complete combustion; inadequate supply causes backdrafting, carbon monoxide, and flame roll-out risks that are reported as safety concerns.
- Guardrail 4-inch rule
- Guardrail balusters should be spaced so a 4-inch sphere cannot pass, and guards are typically at least 36 inches high; failure is a fall-hazard finding.
- Flashing function
- Metal or membrane that directs water at roof penetrations, valleys, and wall intersections; deteriorated or missing flashing is a leading cause of roof leakage.
- Deck ledger attachment
- The connection of a deck to the house structure, including fasteners and flashing; improper attachment or missing flashing is a common collapse and rot hazard.
- Load path
- The continuous route by which building loads transfer from roof to foundation; visible interruptions, notches, or cut framing members are structural observations reported for evaluation.
- Air leakage vs diffusion
- Air movement through gaps transports far more moisture than vapor diffusion through materials; sealing attic and rim-joist air paths is a primary moisture-control measure.
- Grounding versus bonding
- Bonding creates a low-impedance fault path to clear overcurrent devices; grounding references the system to earth. Both are required and serve different functions.
- Backdrafting test
- Checking for reverse draft at a naturally drafting appliance using a flame, smoke, or draft gauge at the draft hood; reverse flow indicates a combustion-safety hazard.
- Moisture meter reading
- A pin meter reports wood moisture percentage; readings around 20 percent or higher indicate conditions favorable to decay and warrant further investigation.
- Non-contact voltage tester
- A screening tool that indicates the presence of an electric field; it cannot confirm absence of voltage, so a solenoid tester or multimeter is used for verification.
- Ladder 4-to-1 rule
- For every 4 feet of working height, the ladder base sits 1 foot from the wall; combined with 3-point contact, it reduces fall risk during exterior inspection.
- Heat exchanger limitation
- Internal heat exchanger cracks are usually not visible without disassembly; inspectors report visible flame distortion, rust, or CO evidence and recommend specialist evaluation.
- Low-slope roof threshold
- Roofs below roughly 4:12 slope require different underlayment and flashing methods than steep-slope coverings; identifying slope guides the description of the roof system.
- Cross-system correlation
- Matching findings across systems, such as staining below a roof penetration or corrosion at a flue, before concluding a cause; improves diagnostic accuracy in the report.
- Plain-language finding format
- A report entry stating location, observed condition, implication, and recommended action, typically referral to a qualified licensed specialist for further evaluation.
- Conflict of interest
- Performing or arranging repair work on a property inspected for compensation within the prohibited period; the code of ethics bars this to preserve impartiality.
- Continuing education requirement
- Annual credit hours a CPI must complete to maintain certification; inspectors track credits against the current requirement and retain documentation.
- Pre-1978 disclosure
- Homes built before 1978 may contain lead-based paint; inspectors avoid disturbing painted surfaces and note the potential presence for client awareness.
- Report as snapshot
- The report reflects conditions observed at the time of inspection only; it is not a warranty of future performance or a prediction of component life expectancy.
- Scope referral judgment
- Recognizing when a condition, such as suspected structural movement or mold, exceeds the standard visual inspection and requires referral to a licensed specialist.