Iran Nezam Architecture Design Exam study materials
Iran Nezam Architecture Design Exam study resources

Iran Nezam Architecture Design Exam cheat sheet

Iran Nezam Architecture Design Exam · Keep the key ideas within reach.

Quick reference

Architectural Design and Spatial Composition

  • Figure-ground ratio: measure built footprint vs. open space on the site plan; a higher built ratio raises density but reduces daylight and courtyard potential.

  • Golden section ratio ≈ 1.618; used to proportion plan rectangles, facade bays, and window openings for visual harmony.

  • Spatial hierarchy rule: sequence public → semi-public → private zones; place the most enclosed space at the deepest point of circulation.

  • Circulation efficiency: net usable area ÷ gross floor area; corridors and stairs typically consume 15–25% of gross area in residential blocks.

  • Promenade architecturale: design the path as a sequence of framed views; each turn or threshold should reveal a new focal element.

  • Module coordination: set a base planning grid (commonly 3.00 m or 3.60 m in Iranian residential work) so structure, partitions, and cladding align.

  • Open-plan depth rule: rooms deeper than about 6 m from a window require secondary light or mechanical ventilation.

  • Threshold articulation: use level change, canopy, or floor material shift to mark the transition between outside and inside.

Quick reference

Building Technology, Structures, and Construction Materials

  • Concrete characteristic strength f_ck is the 28-day cube strength; design strength f_cd = α_cc·f_ck/γ_c with γ_c ≈ 1.5.

  • Steel design yield f_yd = f_y/γ_s with γ_s = 1.15; partial safety factors follow the national loading code.

  • Reinforced concrete beam minimum cover depends on exposure class; typical interior beams use 25–30 mm, exterior 35–40 mm.

  • Brick masonry: compressive strength of fired clay brick commonly 10–20 MPa; mortar strength governs the composite wall capacity.

  • Thermal expansion coefficient: steel ≈ 12×10⁻⁶/°C, concrete ≈ 10×10⁻⁶/°C, aluminum ≈ 23×10⁻⁶/°C; mismatches need movement joints.

  • Slenderness check for columns: λ = l_eff/i; higher slenderness increases second-order moment and reduces axial capacity.

  • Water/cement ratio controls concrete strength and durability; lower w/c raises strength but reduces workability.

  • Seismic detailing: confined masonry requires tie columns and horizontal bond beams at corners and openings.

Quick reference

Building Services and Environmental Systems (MEP)

  • Sensible heat load Q_s = 1.2 × L/s × ΔT (W) for air at standard conditions; latent load follows moisture difference.

  • Illuminance targets: offices 300–500 lux, corridors 100–150 lux, classrooms 300–500 lux; uniformity ratio ≥ 0.6 on the task plane.

  • Water supply pressure: typical fixtures need 100–200 kPa at the outlet; pressure-reducing valves protect fittings above 500 kPa.

  • Stack venting: each drainage stack needs a vent extending above roof; trap seal depth is typically 50–75 mm.

  • Voltage drop limit for branch circuits is usually 3–5%; feeder drops up to 2–3%, keeping total under 5%.

  • Fire alarm zoning: detectors cover roughly 80 m² per detector for smoke type, subject to ceiling height and beam obstructions.

  • Air change rate: kitchens 6–10 ACH, bathrooms 5–8 ACH, parking garages 6 ACH minimum for ventilation design.

  • Elevator traffic: handling capacity 12–15% of population in 5 minutes is a common design target for office buildings.

Quick reference

Building Codes, Regulations, and Professional Practice

  • Occupant load factors: offices ≈ 9 m²/person, classrooms ≈ 2 m²/person, assembly seating by fixed seats; egress width derives from these.

  • Means of egress: two exits required when occupant load exceeds threshold values (commonly 50 for single-exit rooms); travel distance limits apply per occupancy.

  • Stair width minimum for egress generally 1.10 m; handrail height 850–1000 mm above nosing line.

  • Fire resistance ratings are expressed in minutes (e.g., 60, 120); structural elements must match the required compartment rating.

  • Building permit sequence: site plan approval → architectural/structural drawings → technical inspection → occupancy certificate.

  • Professional liability: the architect's supervision duty covers conformity with approved drawings; deviations require written instruction.

  • Accessibility: ramps maximum slope 1:12 with landings every 9 m of run; door clear width ≥ 850 mm.

  • Setback and floor area ratio (FAR) are fixed by the local detailed plan (tarh-e tafzili); verify before massing design.

Quick reference

Urban Design and Site Planning

  • FAR = total gross floor area ÷ plot area; building coverage = footprint ÷ plot area; both are capped by zoning.

  • Solar orientation: in Iranian latitudes, long axis east–west with south-facing glazing maximizes winter gain and allows summer shading.

  • Street hierarchy: local streets ≤ 6 m carriageway, collector 7–9 m, arterial ≥ 11 m; block length 80–150 m supports walkability.

  • Wind shadow rule: a building casts a downwind recirculation zone roughly 3–5 times its height; avoid placing open plazas there.

  • Pedestrian catchment: 5-minute walk ≈ 400 m, 10-minute ≈ 800 m; use for siting schools, clinics, and transit stops.

  • Permeability: site coverage above ~60% increases runoff; permeable paving and bioswales reduce discharge.

  • Density vs. amenity: higher plot ratio requires proportional open space; check the local plan's per-capita green space requirement.

  • View corridors and qanat lines: existing underground water channels constrain foundations and must be preserved in site layout.

Quick reference

History of Iranian and Islamic Architecture

  • Four-iwan plan (chahar iwan): a central courtyard with four vaulted halls on each axis; canonical in Seljuk and later mosques and madrasas.

  • Gonbad: a domed tomb tower; the double-shell dome (as in Soltaniyeh) reduces weight and improves interior proportions.

  • Muqarnas: three-dimensional stalactite corbelling used for corner transitions, vaults, and portals from the 11th century onward.

  • Chahar bagh: four-part garden divided by orthogonal water channels, symbolizing paradise; applied at Pasargadae and later Safavid gardens.

  • Wind catcher (badgir): tower with internal partitions that captures prevailing wind and exhausts warm air; common in Yazd and Kashan.

  • Pishtaq: the tall framed portal preceding an iwan; a hallmark of Timurid and Safavid monumental architecture.

  • Jameh mosque evolution: hypostyle Arab plan → Seljuk four-iwan → Safavid domed and tiled ensembles with elaborate tilework.

  • Structural logic: brick vaulting with pitched brick (tavizeh) technique allows construction of domes and arches without centering.

Quick reference

History of World Architecture and Architectural Theory

  • Classical orders: Doric (no base, simple capital), Ionic (volute capital), Corinthian (acanthus capital); proportion rules set by Vitruvius.

  • Vitruvian triad: firmitas (firmness), utilitas (commodity), venustas (delight) - the traditional basis of architectural value.

  • Modernism principles: form follows function, truth to materials, absence of applied ornament; expressed in the 1920s–30s International Style.

  • Le Corbusier's Five Points: pilotis, free facade, open plan, ribbon windows, roof garden.

  • Postmodernism (1970s–80s) reintroduced historic reference, ornament, and irony in reaction to modernist austerity.

  • Phenomenology in architecture emphasizes bodily experience, materiality, and light rather than abstract geometry.

  • Critical regionalism: uses local climate, materials, and tectonics while engaging modern technique - relevant to Iranian practice.

  • Space syntax and figure-ground analysis are analytical tools for reading urban and architectural form.

Quick reference

Architectural Drawing, Graphic Representation, and Digital Tools

  • Scale: a 1:100 drawing means 1 cm on paper equals 1 m in reality; choose scale so the smallest detail is legible.

  • Orthographic projection: plan, section, and elevation are linked - a section line on the plan must match the section drawing.

  • Line weights: cut elements thickest, secondary elements medium, background/thin lines lightest; hierarchy conveys depth.

  • BIM (Building Information Modeling): a federated model with object attributes; supports clash detection, quantities, and coordination.

  • CAD layers should separate structure, walls, openings, MEP, and annotations for clean plotting and coordination.

  • Perspective vs. axonometric: perspective uses vanishing points; axonometric keeps parallel lines and preserves true measurements along axes.

  • Rendering workflow: model → material assignment → lighting setup (sun and sky) → render → post-production for presentation.

  • Dimensioning rule: dimension to structural grid and finished faces consistently; avoid conflicting chains on the same drawing.

Quick reference

Climatology and Sustainable/Low-Energy Design

  • Iranian climate zones: hot-dry (central plateau), hot-humid (Persian Gulf coast), cold (northwest), and moderate (Caspian).

  • Degree-days: heating degree-days (HDD) and cooling degree-days (CDD) quantify climate severity and size HVAC loads.

  • Orientation rule for hot-dry climates: minimize east/west glazing; use south glazing with overhangs and thermal mass.

  • Thermal mass: heavy walls with a diurnal time lag of 6–10 hours flatten indoor temperature swings in hot-dry climates.

  • Shading coefficient (SC) and U-value govern glazing performance; low-e coatings reduce solar gain while retaining daylight.

  • Natural ventilation: stack effect driven by temperature difference; requires inlet low and outlet high, with a vertical height difference.

  • Evaporative cooling: effective in hot-dry air (low wet-bulb); ineffective when relative humidity exceeds about 40–50%.

  • Passive solar design: south-facing glazing area sized to the collector-to-floor ratio, with night insulation and thermal storage mass.

Quick reference

Structures and Construction Materials

  • Bending moment for a simply supported beam under uniform load: M = w·L²/8; deflection δ = 5wL⁴/(384EI).

  • Shear force for a simply supported beam under uniform load: V = w·L/2 at supports.

  • Column buckling: Euler load P_cr = π²EI/(KL)²; effective length factor K depends on end restraint.

  • Concrete mix: cement, fine aggregate, coarse aggregate, water, admixtures; aggregate occupies roughly 60–75% of volume.

  • Steel sections: I-beams resist bending efficiently; hollow sections resist torsion and are used for exposed columns.

  • Load types: dead (self-weight), live (occupancy), wind, and seismic; combinations follow the national loading code.

  • Foundation choice: shallow footings for competent soil; piles or rafts where bearing capacity is low or settlement is a concern.

  • Masonry arch thrust must be resisted by abutments or tie rods; otherwise walls require thickening or buttressing.

Quick reference

Architectural Design and Spatial Composition (Advanced)

  • Proportion systems: modular (Le Corbusier's Modulor), golden section, and simple integer ratios (1:1, 1:2, 2:3) for facade rhythm.

  • Daylight factor (DF) = interior illuminance ÷ exterior horizontal illuminance × 100; a target of 2% is common for habitable rooms.

  • Room depth rule of thumb: usable daylight depth is about 1.5–2 times the window head height above the work plane.

  • Acoustic separation: place noisy zones (kitchens, lifts) away from bedrooms and studies; buffer with corridors or storage.

  • Flexibility: a structural grid with non-load-bearing partitions allows future plan changes without structural intervention.

  • Courtyard typology: a central open space provides light, ventilation, and privacy; depth-to-height ratio around 1:1 to 2:1 balances both.

  • Universal design: level thresholds, 1500 mm turning circles, and lever handles support accessibility for all users.

  • Massing rule: break large volumes above roughly 20–25 m length to reduce visual bulk and improve daylight penetration.

Quick reference

Building Services and Environmental Systems (Advanced)

  • HVAC load: Q = U·A·ΔT for conduction; add solar gain through glazing using the shading coefficient.

  • Chiller COP = cooling output ÷ electrical input; higher COP means lower energy use and operating cost.

  • Duct sizing: velocity method keeps main ducts at 5–7 m/s and branches at 3–5 m/s to limit noise and pressure loss.

  • Pipe sizing: hot water supply velocity typically ≤ 1.5 m/s to limit noise and erosion; cold water ≤ 2 m/s.

  • Lighting power density (LPD) targets: offices roughly 8–10 W/m² with efficient LED and controls.

  • Daylight-linked controls and occupancy sensors reduce lighting energy by 20–40% in perimeter zones.

  • Earthing and protection: residual current devices (RCD) rated 30 mA protect socket circuits against electric shock.

  • Rainwater harvesting: collect from roof area × rainfall × runoff coefficient; storage sized to dry-period demand.

Quick reference

Building Codes, Regulations, and Professional Practice (Advanced)

  • Fire compartmentation limits spread; openings between compartments require fire-rated doors with self-closing hardware.

  • Smoke control: natural smoke vents or mechanical pressurization of stairs and lobbies; pressurization typically 50 Pa differential.

  • Contract types: lump-sum, unit-price, and cost-plus; each allocates risk differently between client and contractor.

  • Variation orders must be documented in writing and priced before execution to preserve the contractor's claim rights.

  • Retention: a percentage of each payment withheld until defects liability period ends; commonly 5–10%.

  • Professional ethics: disclose conflicts of interest, avoid misrepresentation of qualifications, and maintain confidentiality.

  • Site supervision records: daily reports, inspection requests, and non-conformance notices form the evidence trail for disputes.

  • Handover: as-built drawings, O&M manuals, and the occupancy certificate are required before beneficial use.

Quick reference

Urban Design and Site Planning (Advanced)

  • Transit-oriented development: density and mix within 400–800 m of a station; parking reduced near high-frequency transit.

  • Street enclosure: a width-to-height ratio of 1:1 to 1:2 creates a comfortable pedestrian scale; wider ratios feel exposed.

  • Solar envelope: a volume within which construction does not shade neighbors beyond a permitted duration; derived from sun angles.

  • Urban heat island: vegetation and high-albedo surfaces reduce surface temperature; street trees cool air by 1–3 °C locally.

  • Stormwater: runoff coefficient C ≈ 0.9 for impervious paving, 0.2 for lawns; Q = C·i·A for peak flow.

  • Mixed use: vertical mixing (retail below, housing above) supports street life and reduces car dependence.

  • Accessibility of public space: provide level routes, seating every 50–100 m, and shade along pedestrian paths.

  • Heritage context: new buildings should respect scale, rhythm, and material of the historic fabric without literal imitation.

Quick reference

History of Iranian and Islamic Architecture (Advanced)

  • Sassanid legacy: the iwan and the squinch transition to the dome influenced later Islamic architecture.

  • Seljuk innovations: four-iwan mosque layout, brick muqarnas, and the development of the tomb tower (gonbad).

  • Ilkhanid period: monumental portals and the double-shell dome, exemplified at Soltaniyeh (early 14th century).

  • Timurid architecture: large-scale tile mosaic, ribbed domes, and axial symmetry in madrasas and mosques.

  • Safavid Isfahan: Naqsh-e Jahan square integrates mosque, bazaar, palace, and madrasa around a single urban space.

  • Qajar architecture: introduction of European elements, mirror work, and taller residential blocks in Tehran.

  • Pahlavi era: adoption of international modernism alongside revivalist (neo-Achaemenid) monumentality.

  • Contemporary Iranian architecture: synthesis of climate-responsive vernacular (badgir, courtyard) with modern structure.

Quick reference

History of World Architecture and Architectural Theory (Advanced)

  • Gothic structure: pointed arch, rib vault, and flying buttress concentrate loads and allow tall, thin walls with large windows.

  • Renaissance: revival of classical orders and centralized plans; perspective drawing as a design tool.

  • Baroque: dynamic curves, dramatic light, and spatial continuity; ornament used for theatrical effect.

  • Industrial Revolution: iron and glass (Crystal Palace) enabled large-span, prefabricated structures.

  • Bauhaus: unification of art, craft, and industry; emphasis on standardized components and functional design.

  • Brutalism: exposed concrete, monumental massing, and honest expression of structure (1950s–70s).

  • Deconstructivism: fragmented geometry and destabilized form, challenging structural and compositional conventions.

  • Sustainability theory: life-cycle assessment and embodied carbon extend architectural theory beyond form and function.

Quick reference

Architectural Drawing, Graphic Representation, and Digital Tools (Advanced)

  • Plan conventions: door swings, window symbols, stair direction arrows, and section markers must be consistent across sheets.

  • Section drawing: cut line thickness heavier than background; poché (solid fill) distinguishes cut material from space.

  • Elevation: shows external materials, levels, and openings; hidden structure is not shown but grid lines may be indicated.

  • Detail scale: 1:5 or 1:10 for construction details; 1:50 for general sections; 1:200 for site plans.

  • BIM levels: LOD 200 schematic, LOD 300 coordinated design, LOD 400 fabrication; specify LOD in the contract.

  • Parametric design: rules and parameters drive geometry; useful for facade panels, shading devices, and repetition.

  • Laser scanning and point clouds support as-built documentation and heritage recording.

  • Presentation graphics: use consistent color palette, north arrow, scale bar, and legend on every drawing sheet.

Quick reference

Climatology and Sustainable/Low-Energy Design (Advanced)

  • Olgyay bioclimatic chart: plots comfort zone against temperature and humidity; indicates heating, cooling, or ventilation needs.

  • Givoni chart: extends the comfort analysis to passive strategies such as evaporative cooling and thermal mass.

  • Psychrometric chart: reads dry-bulb, wet-bulb, humidity ratio, and enthalpy; used to size passive and active systems.

  • Embodied carbon: total emissions from material extraction, manufacture, and construction; concrete and steel dominate.

  • Net-zero energy: annual on-site renewable generation equals annual consumption; requires demand reduction first.

  • Green roof benefits: reduces heat gain, manages stormwater, and extends roof membrane life.

  • Solar photovoltaic sizing: annual yield ≈ installed capacity × peak sun hours × system efficiency.

  • Water efficiency: low-flow fixtures and greywater reuse reduce potable demand by 30–50% in residential buildings.

Quick reference

Structures and Construction Materials (Advanced)

  • Reinforced concrete: steel carries tension, concrete carries compression; balanced design uses both efficiently.

  • Shear reinforcement: stirrups resist diagonal tension; spacing tightens near supports where shear is highest.

  • Seismic design: ductile detailing with closely spaced confining hoops in beams and columns improves energy dissipation.

  • Steel connections: bolted (slip-critical or bearing) vs. welded; specify inspection and torque requirements.

  • Timber: strength depends on grain direction; moisture content changes cause shrinkage and movement.

  • Masonry infill: contributes stiffness but can cause soft-story failure if irregularly placed in frames.

  • Soil bearing capacity: verify with geotechnical investigation; allowable pressure typically 100–300 kPa for competent soil.

  • Retaining walls: lateral earth pressure increases with depth; drainage behind the wall prevents hydrostatic buildup.

Quick reference

Architectural Design and Spatial Composition (Composition Rules)

  • Balance: symmetrical (mirror) or asymmetrical (visual weight offset by mass, color, or detail).

  • Rhythm: repetition of bays, windows, or columns at regular intervals creates visual order.

  • Scale: relate element size to human dimensions; oversized elements signal monumentality, undersized ones intimacy.

  • Contrast: juxtapose materials, light, or geometry to emphasize focal points and hierarchy.

  • Unity: use a consistent module, material palette, or color scheme to bind disparate parts.

  • Proportion: the ratio of width to height in a facade should be deliberate; 1:1, 1:1.5, and 1:2 are common.

  • Circulation clarity: a legible path from entry to destination reduces wayfinding confusion.

  • Threshold and transition: gradual change of light, level, or material eases the psychological shift between spaces.

Quick reference

Building Services and Environmental Systems (Plumbing and Electrical)

  • Water supply system: storage tank → booster pump → distribution risers → fixtures; pressure maintained by gravity or pump.

  • Drainage slope: horizontal soil pipes fall 1–2% (10–20 mm per meter) to maintain self-cleansing velocity.

  • Trap and vent: each fixture needs a trap; vent pipes equalize pressure and prevent siphonage of the seal.

  • Electrical distribution: main panel → sub-panels → branch circuits; separate circuits for lighting, sockets, and HVAC.

  • Load calculation: sum connected loads × demand factor; size the main breaker and cable accordingly.

  • Cable sizing: cross-sectional area chosen for current-carrying capacity, voltage drop, and short-circuit withstand.

  • Emergency lighting: exit signs and escape route lighting on a separate circuit with battery backup.

  • Metering: separate metering for tenant spaces supports fair billing and energy management.

Quick reference

Building Codes, Regulations, and Professional Practice (Fire and Safety)

  • Fire resistance of structural elements: beams, columns, and slabs must achieve the required rating in minutes.

  • Escape route: maximum travel distance to an exit depends on occupancy; assembly and industrial uses have shorter limits.

  • Exit width: total egress width = occupant load × width factor; stairs and doors must satisfy the minimum.

  • Fire doors: self-closing, with a rating matching the compartment; hold-open devices must release on alarm.

  • Detection: smoke detectors in circulation and sleeping areas; heat detectors in kitchens and plant rooms.

  • Sprinklers: design density and coverage area depend on hazard classification; residential and office differ.

  • Emergency signage: illuminated exit signs visible from any point in the escape route.

  • Assembly occupancy: additional requirements for panic hardware, aisle width, and seating density.

Quick reference

Urban Design and Site Planning (Site Analysis)

  • Topography: contour lines show slope; slope = vertical interval ÷ horizontal distance; steep sites require terracing or retaining walls.

  • Drainage: site grading should direct water away from buildings; minimum fall 1–2% on paved surfaces.

  • Solar path: use sun path diagrams for the site latitude to determine shadow length and orientation.

  • Noise: buffer with landscape, walls, or building massing; place bedrooms away from the noise source.

  • Access: vehicle entry, pedestrian entry, and service access should be separated to avoid conflict.

  • Vegetation: existing trees influence microclimate and should be preserved where possible; root zones constrain foundations.

  • Views: orient living spaces toward desirable views; screen undesirable ones with planting or screens.

  • Utilities: locate water, sewer, and power connections early; easements constrain building placement.

Quick reference

History of Iranian and Islamic Architecture (Elements)

  • Iwan: a vaulted hall open on one side to a courtyard; a central element of Iranian mosque and house design.

  • Courtyard (hayat): provides privacy, microclimate moderation, and a social focus in traditional houses.

  • Wind catcher (badgir): a tower with internal partitions that captures and circulates air; a passive cooling device.

  • Qanat: an underground aqueduct that supplies water to settlements and gardens; a major Iranian hydraulic innovation.

  • Caravanserai: a roadside inn for travelers; typically a square plan with a central courtyard and cells around it.

  • Bazaar: a covered market street with domed bays and shops; an economic and social spine of Iranian cities.

  • Hammam: a public bath with a sequence of cold, warm, and hot rooms; often domed with skylights for humidity control.

  • Tilework: glazed tile (kashi) used for decoration and durability; blue-and-turquoise palette is characteristic.

Quick reference

History of World Architecture and Architectural Theory (Movements)

  • Classical Greek: proportion and symmetry; the Parthenon exemplifies optical refinements and column rhythm.

  • Roman: arch, vault, and concrete enabled large interior spaces such as the Pantheon.

  • Gothic: pointed arches and flying buttresses allowed tall naves with large stained-glass windows.

  • Renaissance: perspective, centralized plans, and classical orders; Brunelleschi's dome revived Roman techniques.

  • Modernism: functionalism, open plan, and industrial materials; the International Style spread after 1930.

  • Postmodernism: historic quotation and ornament; reaction against modernist austerity.

  • Parametricism: algorithmic design and continuous differentiation; enabled by digital tools.

  • Sustainable design: passive strategies, renewable energy, and life-cycle thinking shape contemporary practice.

Quick reference

Architectural Drawing, Graphic Representation, and Digital Tools (Representation)

  • Plan: horizontal cut at about 1.2 m above floor; shows walls, openings, stairs, and fixtures.

  • Section: vertical cut through the building; shows structure, levels, and materials.

  • Elevation: exterior view showing materials, openings, and roofline; no perspective distortion.

  • Axonometric: parallel projection preserving scale along axes; useful for construction and presentation.

  • Perspective: uses vanishing points; one-point for interiors, two-point for exteriors.

  • Rendering: material, lighting, and shadow simulation; used for design communication.

  • CAD standards: layers, line weights, and text styles ensure consistency across drawings.

  • BIM: object-based modeling with data; supports coordination, quantities, and facility management.

Quick reference

Climatology and Sustainable Design (Passive Strategies)

  • Passive solar heating: south-facing glazing with thermal mass stores heat during the day and releases it at night.

  • Shading devices: overhangs, louvers, and trees reduce summer solar gain while allowing winter sun.

  • Natural ventilation: cross-ventilation and stack effect reduce cooling loads; requires openings and height difference.

  • Thermal mass: heavy walls and floors moderate temperature swings; effective in hot-dry and cold climates.

  • Evaporative cooling: effective in low-humidity climates; uses water evaporation to cool air.

  • Green roof: reduces heat gain and stormwater runoff; requires structural capacity and waterproofing.

  • Daylighting: windows, skylights, and light shelves reduce electric lighting; control glare with shading.

  • Renewable energy: photovoltaic panels and solar water heaters reduce fossil fuel use.

Quick reference

Structures and Construction Materials (Materials)

  • Concrete: strong in compression, weak in tension; reinforced with steel to resist tension.

  • Steel: high strength in tension and compression; requires fire protection and corrosion protection.

  • Masonry: strong in compression, weak in tension; requires adequate thickness and buttressing.

  • Timber: renewable, light, and strong along the grain; requires moisture and fire protection.

  • Glass: transparent but brittle; used in facades with structural framing and safety glazing.

  • Aluminum: light and corrosion-resistant; used for window frames and cladding.

  • Composites: fiber-reinforced polymers offer high strength-to-weight ratios for specialized applications.

  • Recycled materials: reduce embodied energy and support sustainability goals.

Quick reference

Building Services and Environmental Systems (HVAC)

  • Heating: boilers, heat pumps, or solar systems supply heat to radiators or underfloor heating.

  • Cooling: chillers, split units, or evaporative coolers remove heat from spaces.

  • Ventilation: mechanical or natural; supplies fresh air and removes pollutants.

  • Air distribution: ducts carry conditioned air; sizing depends on flow rate and pressure loss.

  • Controls: thermostats and building management systems optimize energy use.

  • Energy efficiency: high COP and low LPD reduce operating costs.

  • Maintenance: filters and coils require regular cleaning to maintain performance.

  • Indoor air quality: adequate ventilation and filtration reduce pollutants and improve comfort.

Quick reference

Building Codes, Regulations, and Professional Practice (Contracts)

  • Contract documents: drawings, specifications, and conditions of contract define the scope.

  • Bills of quantities: itemized list of work for pricing and payment.

  • Variations: changes to scope must be documented and priced.

  • Payment: progress payments based on measured work; retention withheld until completion.

  • Defects liability: period after completion during which defects are corrected.

  • Insurance: professional indemnity and construction all-risk policies protect parties.

  • Dispute resolution: negotiation, mediation, arbitration, or litigation.

  • Ethics: integrity, confidentiality, and avoidance of conflicts of interest.

Quick reference

Urban Design and Site Planning (Public Space)

  • Public space: accessible to all; supports social interaction and recreation.

  • Street design: balance movement and place; consider pedestrians, cyclists, and vehicles.

  • Green infrastructure: parks, trees, and water features improve microclimate and stormwater management.

  • Accessibility: level routes, seating, and shade support use by all ages and abilities.

  • Safety: lighting, visibility, and active frontages reduce crime and improve comfort.

  • Heritage: preserve historic fabric and scale in new development.

  • Density: supports transit and services; requires open space and infrastructure.

  • Community engagement: involve residents in planning decisions for better outcomes.

Quick reference

History of Iranian and Islamic Architecture (Urban Form)

  • City structure: bazaar, mosque, and citadel form the core of traditional Iranian cities.

  • Neighborhood (mahalle): residential unit with a mosque, bath, and water supply.

  • Street network: narrow, shaded lanes connect neighborhoods to the bazaar.

  • Courtyard houses: introverted design provides privacy and climate control.

  • Water system: qanats and cisterns supply water; gardens (bagh) integrate water and shade.

  • Defensive walls: protect the city; gates mark entry points.

  • Urban squares (maydan): public spaces for gathering, commerce, and ceremony.

  • Modernization: grid plans and wide streets introduced in the 20th century changed traditional form.