Iran Nezam Architecture Design Exam flashcards
Iran Nezam Architecture Design Exam · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Figure-ground ratio
- The ratio of built footprint to open space on a site plan. A higher ratio increases density but reduces daylight, ventilation, and courtyard potential.
- Golden section
- A proportion of approximately 1.618, used to size rectangles, facade bays, and window openings for visual harmony in architectural composition.
- Concrete design strength
- Design compressive strength f_cd equals α_cc times characteristic strength f_ck divided by the partial safety factor γ_c, typically 1.5.
- Slenderness ratio
- Lambda equals effective length divided by radius of gyration. Higher slenderness increases second-order moments and reduces column axial capacity.
- Sensible heat load
- Q_s equals 1.2 times airflow in liters per second times temperature difference in kelvin, giving watts for air at standard conditions.
- Trap seal depth
- The water depth in a plumbing trap, typically 50 to 75 millimeters, that prevents sewer gas from entering the building.
- Occupant load factor
- Floor area per person used to calculate egress requirements; offices about 9 square meters per person, classrooms about 2.
- Floor area ratio
- Total gross floor area divided by plot area. It is capped by the local detailed plan and governs building massing.
- Solar orientation rule
- In Iranian latitudes, orient the long axis east-west with south glazing to maximize winter solar gain and allow summer shading.
- Chahar iwan plan
- A courtyard plan with four vaulted halls on each axis, canonical in Seljuk and later mosques and madrasas.
- Badgir
- A wind catcher tower with internal partitions that captures prevailing wind and exhausts warm air, common in Yazd and Kashan.
- Vitruvian triad
- Firmitas, utilitas, and venustas: firmness, commodity, and delight, the traditional basis of architectural value.
- Five Points of Le Corbusier
- Pilotis, free facade, open plan, ribbon windows, and roof garden, defining modernist architectural principles.
- Orthographic projection
- Plan, section, and elevation linked so that a section line on the plan matches the section drawing exactly.
- Building information modeling
- An object-based federated model with attributes supporting clash detection, quantities, coordination, and facility management.
- Heating degree-days
- A measure of climate severity calculated from temperature differences below a base temperature, used to size heating systems.
- Shading coefficient
- The ratio of solar heat gain through glazing to that through clear glass; lower values reduce cooling loads.
- Simply supported beam moment
- For uniform load w over span L, the maximum bending moment is w times L squared divided by eight.
- Euler buckling load
- Critical load equals pi squared times EI divided by the square of effective length KL, governing slender column capacity.
- Daylight factor
- Interior illuminance divided by exterior horizontal illuminance times 100; a target of 2 percent is common for habitable rooms.
- Chiller COP
- Coefficient of performance equals cooling output divided by electrical input; higher values mean lower energy use and operating cost.
- Fire compartmentation
- Division of a building into fire-rated zones with rated walls and self-closing doors to limit fire and smoke spread.
- Solar envelope
- A volume within which construction does not shade neighboring properties beyond a permitted duration, derived from sun angles.
- Soltaniyeh dome
- An early fourteenth-century Ilkhanid double-shell dome, notable for its monumental scale and structural innovation.
- Flying buttress
- A Gothic structural element that transfers vault thrust to external piers, allowing tall naves with large stained-glass windows.
- Poché
- Solid fill in a section drawing that distinguishes cut material from open space, usually shown with heavier line weight.
- Bioclimatic chart
- A graph plotting temperature and humidity against a comfort zone, indicating heating, cooling, or ventilation strategies.
- Shear reinforcement
- Stirrups in a concrete beam that resist diagonal tension, spaced more closely near supports where shear is highest.
- Visual balance
- Symmetrical or asymmetrical distribution of visual weight achieved through mass, color, and detail in a composition.
- Drainage slope
- Horizontal soil pipes fall 1 to 2 percent, about 10 to 20 millimeters per meter, to maintain self-cleansing velocity.
- Travel distance
- The maximum permitted distance from any point to an exit, set by occupancy type and building code requirements.
- Qanat
- An underground aqueduct that supplies water to Iranian settlements and gardens, a major hydraulic innovation.