CIT flashcards
CIT · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- PSI to feet of head
- One psi of static pressure supports a column of water 2.31 feet high; multiply psi by 2.31 to find equivalent head, or multiply feet of head by 0.433 to get psi.
- Flow velocity limit in laterals
- Design lateral pipe flow at or below 5 feet per second to limit friction loss, noise, and water hammer; mainlines are commonly limited to about 7 feet per second.
- Precipitation rate formula
- Precipitation rate in inches per hour equals 96.25 times the sprinkler's gallons per minute divided by the area it covers in square feet.
- Total dynamic head
- Total dynamic head is the sum of elevation lift, suction lift, friction losses through pipe and fittings, and the operating pressure required at the farthest head.
- Nozzle flow versus pressure
- Flow through a fixed orifice varies with the square root of pressure, so doubling the pressure increases flow by about 41 percent rather than doubling it.
- Backsiphonage
- Backflow caused by negative or sub-atmospheric pressure in the supply line, which pulls nonpotable water into the potable system, as can happen during a main break.
- Backpressure backflow
- Backflow that occurs when downstream pressure exceeds the supply pressure, such as from a boiler, booster pump, or elevated tank connected to the system.
- RPZ assembly
- A reduced pressure zone assembly has two independent check valves and a differential relief valve; it protects against both backpressure and backsiphonage at high hazard connections.
- Air gap
- A physical separation between the potable supply outlet and the flood-level rim of the receiving vessel; it provides the highest level of cross-connection protection.
- Atmospheric vacuum breaker
- An atmospheric vacuum breaker must be installed at least six inches above the highest downstream outlet, with no shutoff valves or continuous pressure allowed downstream.
- Solenoid coil resistance
- A healthy 24-volt irrigation solenoid coil typically measures about 20 to 60 ohms; infinite resistance indicates an open coil, and near-zero resistance indicates a short.
- Controller transformer output
- Irrigation controllers supply 24 volts AC to solenoid valves; measuring at the station terminal and common while a valve is active confirms the transformer and output are working.
- Voltage drop rule
- Keep voltage drop on valve wiring below about 10 percent of supply; long runs and undersized wire add resistance and can prevent valves from opening.
- Rain sensor wiring
- Most irrigation rain sensors are normally closed switches wired in series with the common wire; when rainfall is detected the circuit opens and irrigation stops.
- Decoder system
- A two-wire control architecture in which addressable decoders at each valve receive coded signals over a single path, replacing individual home-run wires to the controller.
- Matched precipitation rate
- Using sprinkler heads or nozzles with similar precipitation rates within one zone prevents overwatering and dry spots that occur when application rates differ.
- Pressure-compensating emitter
- A drip emitter that maintains a constant discharge, typically 0.5 to 2 gallons per hour, across a wide range of inlet pressures, keeping flow uniform along the zone.
- Swing joint
- A flexible fitting assembly of elbows and nipples that allows a sprinkler head to be adjusted for height, angle, and grade without stressing the lateral pipe.
- Check valve in rotor
- A device built into some rotors that holds water in the lateral when the zone shuts off, preventing low-head drainage and puddling at the lowest heads.
- PVC solvent cementing
- A joining method for PVC pipe using primer and solvent cement; apply primer, cement both surfaces, insert with a quarter turn, and allow proper cure before pressure testing.
- Call 811 before digging
- In the United States, call the free utility locate service before trenching; wait the required period and hand-dig near marked utilities to avoid damaging buried lines.
- Mainline trench depth
- Irrigation mainlines are typically buried 12 to 18 inches deep and below the frost line in cold climates, while laterals are commonly 6 to 12 inches deep.
- Hydrostatic pressure test
- New irrigation piping is tested at about 1.5 times design pressure, or at least 50 psi above working pressure, held for a specified period before backfilling.
- Flushing before heads
- Open and flush mainlines and lateral ends to remove debris before installing sprinkler heads and nozzles, since debris clogs nozzles, valves, and emitters.
- Valve won't close
- Common causes include debris trapped in the valve seat, a torn or worn diaphragm, or a solenoid plunger stuck in the open position, allowing flow to continue.
- Winterization blowout
- Remove water from irrigation lines with compressed air at moderate pressure, opening zones one at a time, to prevent freeze damage to pipe, valves, and backflow devices.
- Low pressure diagnosis
- Check for partially closed valves, clogged filters or screens, leaks, undersized pipe, or a failing pump before assuming that a sprinkler head is defective.
- Water hammer causes
- Sudden valve closure, high flow velocity, or missing air chambers and shock arrestors create pressure surges that can damage pipe, valves, and fittings.
- Trench protective system
- OSHA requires cave-in protection such as sloping, shoring, or trench boxes for excavations five feet deep or more, plus a means of exit within 25 feet.
- GFCI protection outdoors
- Outdoor and wet-location electrical circuits, including controller receptacles, require ground-fault circuit interrupter protection to reduce the risk of electric shock.
- WaterSense labeled products
- An EPA program identifying irrigation controllers and heads that meet water-efficiency criteria; many rebate programs and local codes require or reward these products.
- Backflow tester certification
- Most jurisdictions require annual testing of backflow prevention assemblies by a certified tester, with results reported to the local water authority.