ITC Thermographer Level III study plan
ITC Thermographer Level III · Give each week a clear focus.
8 weeks · About 7 hours per week
Infrared theory and thermography fundamentals
Derive and explain the Planck, Wien, and Stefan-Boltzmann relationships and state what each predicts about peak wavelength, total exitance, and temperature sensitivity
Compute radiated exitance and spectral band fractions for a blackbody at three temperatures using a spreadsheet you build yourself
Distinguish emissivity, reflectivity, transmissivity, and absorptivity and apply Kirchhoff's law to a real target surface
Quantify how a 1 K target change maps to an apparent temperature change at 3-5 µm versus 8-14 µm for a 300 K target
Your checkpoint
A one-page formula sheet plus a spreadsheet that outputs blackbody band radiance for any entered temperature and band, verified against two hand calculations
Infrared theory and thermography fundamentals & Equipment, measurement accuracy and personnel qualification
Explain how detector type (microbolometer, cooled photon, InGaAs, QWIP) sets spectral response, NETD, frame rate, and calibration stability
Calculate IFOV and measurement spot size for three lens/detector combinations and decide whether a target fills the required pixel count
Identify the atmospheric transmission windows and explain humidity, CO2, and path length effects on measured temperature
Set up and justify an emissivity and reflected-apparent-temperature correction for a low-emissivity target
Your checkpoint
A worked spot-size and spectral-band selection memo for three hypothetical targets (electrical lug, steam line, exterior wall) with the lens and band you would choose and why
Equipment, measurement accuracy and personnel qualification
List the sources of measurement uncertainty in a radiometric measurement and rank them by typical magnitude for a 100 °C target
Describe a blackbody calibration check procedure and state acceptable drift criteria you would adopt
Interpret a calibration certificate: emissivity setting, uncertainty statement, and traceability chain
Explain how ambient temperature drift, non-uniformity correction, and integration time affect accuracy in the field
Compare radiometric versus non-radiometric imagers for program needs
Your checkpoint
A written accuracy budget for one measurement scenario showing each uncertainty contributor, its magnitude, and the combined expanded uncertainty
Thermography program management and standards
Map the elements of a thermography program: written procedure, route design, severity criteria, training records, and equipment control
Draft severity classification criteria (delta-T thresholds and absolute limits) for electrical and mechanical assets and justify each threshold
Identify which consensus standards and recommended practices govern inspection, calibration, and qualification, and state what each covers without quoting them
Design a route and naming convention that makes repeat surveys comparable over time
Your checkpoint
A program manual outline with a written severity-criteria table for at least three asset classes and the rationale for each threshold
Thermography program management and standards & Advanced applications, analysis and reporting
Build a corrective-action workflow that links a finding to a work order, a recheck interval, and a closeout record
Define qualification levels, experience hours, and recertification requirements you would require of your own team
Establish an equipment control log covering calibration dates, lens inventory, and performance checks
Draft a report template that separates observation, measurement, interpretation, and recommendation
Your checkpoint
A complete sample inspection report for a fictional facility including images described in text, severity calls, and prioritized recommendations, plus the corrective-action tracking sheet
Advanced applications, analysis and reporting
Analyze an electrical finding using load, delta-T, and phase comparison, and explain why absolute temperature alone can mislead
Interpret mechanical findings such as bearing friction, coupling misalignment, and belt wear from thermal patterns described in text
Evaluate building-envelope findings: insulation voids, air leakage, and moisture, including the required thermal gradient and its direction
Explain solar loading, wind, and emissivity variation as confounders in exterior surveys and state how to control for each
Justify when thermography is not the right tool for a stated problem
Your checkpoint
Four case analyses (one electrical, one mechanical, one envelope, one refusal) each with the data you would collect, the interpretation, and the confidence level
Advanced applications, analysis and reporting & Equipment, measurement accuracy and personnel qualification
Perform a root-cause analysis on a finding that has two plausible explanations and state the discriminating test
Write recommendations that specify action, urgency, and owner rather than generic advice
Review a peer report against a checklist and identify at least five defects in reasoning or documentation
Explain how to present uncertainty and limitations to a non-technical client without overstating confidence
Your checkpoint
A redlined critique of a peer-style report with a corrected version of its weakest section and a client-facing limitations paragraph
Infrared theory and thermography fundamentals & Thermography program management and standards & Advanced applications, analysis and reporting & Equipment, measurement accuracy and personnel qualification
Complete a timed 100-question mixed-domain practice set and score each domain separately
Re-derive the five calculations you missed most often until you can do them without notes
Reconcile your severity criteria and accuracy budget against the standards you identified in week 4
List your remaining weak objectives and schedule targeted review before the exam
Your checkpoint
A scored practice exam with a per-domain error log and a one-page final review sheet of your ten weakest objectives
Milestones
Week 2: You can compute spot size, IFOV, and band radiance from memory and explain which band suits a given target temperature
Week 4: Your accuracy budget closes to a stated expanded uncertainty, and your severity table has defensible thresholds for three asset classes
Week 6: You can defend each severity call and recommendation in your sample report against a challenge from a reviewer
Week 8: Practice score is at or above your target in every domain, with no domain more than 10 points below your average